CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring

We fabricated a carbon nanotube (CNT)/ polydimethylsiloxane (PDMS) composite-based dry ECG electrode that can be readily connected to conventional ECG devices, and showed its long-term wearable monitoring capability and robustness to motion and sweat. While the dispersion of CNTs in PDMS is challenging, we optimized the process to disperse untreated CNTs within PDMS by mechanical force only. The electrical and mechanical characteristics of the CNT/PDMS electrode were tested according to the concentration of CNTs and its thickness. The performances of ECG electrodes were evaluated by using 36 types of electrodes which were fabricated with different concentrations of CNTs, and with a differing diameter and thickness. The ECG signals were obtained by using electrodes of diverse sizes to observe the effects of motion and sweat, and the proposed electrode was shown to be robust to both factors. The CNT concentration and diameter of the electrodes were critical parameters in obtaining high-quality ECG signals. The electrode was shown to be biocompatible from the cytotoxicity test. A seven-day continuous wearability test showed that the quality of the ECG signal did not degrade over time, and skin reactions such as itching or erythema were not observed. This electrode could be used for the long-term measurement of other electrical biosignals for ubiquitous health monitoring including EMG, EEG, and ERG.

[1]  Jee Hyun Choi,et al.  A dry release of polyimide electrodes using Kapton film and application to EEG signal measurements , 2011 .

[2]  M. Terrones,et al.  Robust, Conducting, and Transparent Polymer Composites Using Surface‐Modified and Individualized Double‐Walled Carbon Nanotubes , 2008 .

[3]  L. Geddes,et al.  Temporal changes in electrode impedance while recording the electrocardiogram with “Dry” electrodes , 1973, Annals of Biomedical Engineering.

[4]  Tilak Dias,et al.  Fibre-meshed transducers based real time wearable physiological information monitoring system , 2004, Eighth International Symposium on Wearable Computers.

[5]  Joung-Sook Hong,et al.  Extension-induced dispersion of multi-walled carbon nanotube in non-Newtonian fluid , 2007 .

[6]  G. Ruffinia,et al.  First human trials of a dry electrophysiology sensor using a carbon nanotube array interface , 2008 .

[7]  P. Sheng,et al.  Characterizing and Patterning of PDMS‐Based Conducting Composites , 2007 .

[8]  M. Coyle,et al.  Ambulatory cardiopulmonary data capture , 2002, 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578).

[9]  K. Park,et al.  Flexible polymeric dry electrodes for the long-term monitoring of ECG , 2008 .

[10]  Eugene M. Terentjev,et al.  Dispersion rheology of carbon nanotubes in a polymer matrix , 2006 .

[11]  Suresh Valiyaveettil,et al.  Mechanics of prestressed polydimethylsiloxane-carbon nanotube composite , 2006 .

[12]  O. Such,et al.  Dry electrodes for monitoring of vital signs in functional textiles , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Seulki Lee,et al.  An Attachable ECG Sensor Bandage with Planar-Fashionable Circuit Board , 2009, 2009 International Symposium on Wearable Computers.

[14]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[15]  Tingrui Pan,et al.  Photopatternable Conductive PDMS Materials for Microfabrication , 2008 .

[16]  R T Knight,et al.  A dry electrode for EEG recording. , 1994, Electroencephalography and clinical neurophysiology.

[17]  Sang Hoon Lee,et al.  Automatic aligning and bonding system of PDMS layer for the fabrication of 3D microfluidic channels , 2005 .

[18]  Byoungho Lee,et al.  Fabrication of long and discontinuous natural fiber reinforced polypropylene biocomposites and their mechanical properties , 2009 .

[19]  K. Park,et al.  The electrically noncontacting ECG measurement on the toilet seat using the capacitively-coupled insulated electrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[20]  Petra Pötschke,et al.  Dispersion, agglomeration, and network formation of multiwalled carbon nanotubes in polycarbonate melts , 2008 .

[21]  M. Toner,et al.  Cellular Micropatterns on Biocompatible Materials , 1998, Biotechnology progress.

[22]  Giulio Ruffini,et al.  A dry electrophysiology electrode using CNT arrays , 2005, physics/0510145.

[23]  J. Muthuswamy,et al.  Flexible Chip-Scale Package and Interconnect for Implantable MEMS Movable Microelectrodes for the Brain , 2009, Journal of Microelectromechanical Systems.

[24]  Ali Khademhosseini,et al.  Benchtop fabrication of PDMS microstructures by an unconventional photolithographic method , 2010, Biofabrication.

[25]  L. Kirkup,et al.  A direct comparison of wet, dry and insulating bioelectric recording electrodes. , 2000, Physiological measurement.

[26]  J. Muller,et al.  Mobile patient monitoring based on impedance-loaded SAW-sensors , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  X Zhang,et al.  Continuous carbon nanotube reinforced composites. , 2008, Nano letters.

[28]  Peter Enoksson,et al.  Micromachined electrodes for biopotential measurements , 2001 .

[29]  Mark G. Allen,et al.  Micropatternable elastic electrets based on a PDMS/carbon nanotube composite , 2010 .

[30]  S. A. Stern,et al.  Diffusion of Gases in Silicone Polymers: Molecular Dynamics Simulations , 1998 .

[31]  P. M. Mendes,et al.  Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.