Short-stemmed uncemented femoral component for primary hip arthroplasty.

A short-stemmed femoral implant differing from conventional design assumptions demonstrates that immediate three-point proximal femur fixation is possible without stem fixation. A double-wedged contour and neck shaft angle of 150 degrees help secure immediate stability and lessen an excessive varus moment. Results of 20 patients with at least one year of follow-up study are encouraging. Nineteen (95%) are classified as satisfactory with a Harris hip score of 44.5 before and 97.8 after surgery. One patient was revised for loosening; no patient has thigh pain. The gratifying early results justify further clinical investigation.

[1]  W H Harris,et al.  Femoral component loosening using contemporary techniques of femoral cement fixation. , 1982, The Journal of bone and joint surgery. American volume.

[2]  K E Marks,et al.  A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. , 1982, The Journal of bone and joint surgery. American volume.

[3]  R. Crowninshield,et al.  An analysis of femoral component stem design in total hip arthroplasty. , 1980, The Journal of bone and joint surgery. American volume.

[4]  F.R.S. F.R.C.S. F.A.C.S Professor Sir John Charnley C.B.E. Low Friction Arthroplasty of the Hip , 1979, Springer Berlin Heidelberg.

[5]  S D Cook,et al.  The influence of design parameters on calcar stresses following femoral head arthroplasty. , 1980, Journal of biomedical materials research.

[6]  M A Ritter,et al.  Long-term comparison of the Charnley, Muller, and Trapezoidal-28 total hip prostheses. A survival analysis. , 1987, The Journal of arthroplasty.

[7]  P. Ring,et al.  Osteolytic changes in the upper femoral shaft following porous-coated hip replacement. , 1985, The Journal of bone and joint surgery. British volume.

[8]  R M Pilliar,et al.  The effect of movement on the bonding of porous metal to bone. , 1973, Journal of biomedical materials research.

[9]  R M Pilliar,et al.  Osteogenic phenomena across endosteal bone-implant spaces with porous surfaced intramedullary implants. , 1981, Acta orthopaedica Scandinavica.

[10]  H. Amstutz,et al.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. , 1979, Clinical orthopaedics and related research.

[11]  S. Tooke,et al.  The UCLA Charnley Experience: A Long‐term Follow‐up Study Using Survival Analysis , 1986, Clinical orthopaedics and related research.