Traumatic dislocation of the S1 polyaxial pedicle screw head: a case report.

Polyaxial screw head dislocation in the absence of a manufacture defect is extremely rare and represents a biomechanical overload of the screw, leading to early failure. A 58-year-old gentleman underwent instrumented fusion using polyaxial pedicle screws-titanium rod construct with interbody cage for spondylolytic spondylolisthesis at the L5/S1 level. He attempted to bend forward ten days after the surgery which resulted in a dislocation of the right S1 polyaxial screw head from the screw shank with recurrence of symptoms. He underwent revision surgery uneventfully. This case highlights the need to pay particular attention to the strength of fixation and the amount of release to avoid such a complication.

[1]  W. Walsh,et al.  The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review , 2015, BMC Musculoskeletal Disorders.

[2]  C. Logroscino,et al.  Complications in lumbar spine surgery: A retrospective analysis , 2013, Indian journal of orthopaedics.

[3]  M. Aebi,et al.  Pedicle screw instrumentation and spinal deformities: have we gone too far? , 2013, European Spine Journal.

[4]  Hubert Labelle,et al.  Biomechanical Analysis of 4 Types of Pedicle Screws for Scoliotic Spine Instrumentation , 2012, Spine.

[5]  A. Mannion,et al.  To fuse or not to fuse in lumbar degenerative spondylolisthesis: do baseline symptoms help provide the answer? , 2012, European Spine Journal.

[6]  William C Welch,et al.  Spinal facet joint biomechanics and mechanotransduction in normal, injury and degenerative conditions. , 2011, Journal of biomechanical engineering.

[7]  T. Witham,et al.  Sacropelvic Fixation: Two Case Reports of a New Percutaneous Technique , 2011, Spine.

[8]  K. Kebaish Sacropelvic Fixation: Techniques and Complications , 2010, Spine.

[9]  A. Crawford,et al.  Intraoperative Techniques to Reduce the Potential of Set-screw Loosening in Long Spinal Constructs: A Static and Fatigue Biomechanical Investigation , 2010, Journal of spinal disorders & techniques.

[10]  E. Fishman,et al.  Low Profile Pelvic Fixation: Anatomic Parameters for Sacral Alar-Iliac Fixation Versus Traditional Iliac Fixation , 2009, Spine.

[11]  A. Mehbod,et al.  Evidence-Based Medicine Analysis of Isthmic Spondylolisthesis Treatment Including Reduction Versus Fusion In Situ for High-Grade Slips , 2007, Spine.

[12]  Shih-Hao Chen,et al.  Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support , 2007, BMC musculoskeletal disorders.

[13]  L. Riley,et al.  Pelvic fixation in spine surgery. Historical overview, indications, biomechanical relevance, and current techniques. , 2005, The Journal of bone and joint surgery. American volume.

[14]  L. Lenke,et al.  Monaxial Versus Multiaxial Thoracic Pedicle Screws in the Correction of Adolescent Idiopathic Scoliosis , 2005, Spine.

[15]  C. Reitman,et al.  Physical Characteristics of Polyaxial-Headed Pedicle Screws and Biomechanical Comparison of Load With Their Failure , 2003, Spine.

[16]  R. Castelein,et al.  Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations , 2002, European Spine Journal.

[17]  X. Weng,et al.  [Complications associated with the technique of pedicle screw fixation]. , 2002, Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae.

[18]  R. Winter,et al.  Complications associated with pedicle screws. , 1999, The Journal of bone and joint surgery. American volume.

[19]  P. A. Cripton,et al.  Compressive strength of interbody cages in the lumbar spine: the effect of cage shape, posterior instrumentation and bone density , 1998, European Spine Journal.

[20]  J. Lotz,et al.  Biomechanical Analysis of Lumbosacral Fixation , 1996, Spine.

[21]  C. Edwards,et al.  Instrumented reduction of spondylolisthesis. , 1994, Spine.

[22]  S. Esses,et al.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. , 1993, Spine.

[23]  O. Boachie-Adjei,et al.  Treatment of adult spinal deformity with fusion to the sacrum using CD instrumentation. , 1991, Journal of spinal disorders.

[24]  J. Camp,et al.  Immediate Complications of Cotrel‐Dubousset Instrumentation to the Sacro‐Pelvis A Clinical and Biomechanical Study , 1990, Spine.

[25]  B. Allen,et al.  A 1988 PERSPECTIVE ON THE GALVESTON TECHNIQUE OF PELVIC FIXATION , 1988, The Orthopedic clinics of North America.

[26]  J Dubousset,et al.  NEW UNIVERSAL INSTRUMENTATION IN SPINAL SURGERY , 1988, Clinical orthopaedics and related research.

[27]  D. Bradford,et al.  Treatment of Severe Spondylolisthesis: A Combined Approach for Reduction and Stabilization , 1979, Spine.