Three-phase three-level active power filter with a clamped capacitor topology

An eight-switch voltage source inverter for harmonic elimination and reactive power compensation is presented. The adopted inverter is based on a three-phase two-leg clamped capacitor circuit topology to reduce the voltage stress on the power semiconductors. Four active switches and one clamped capacitor are used in each inverter leg to achieve three-level pulse-width modulation. The adopted inverter is operated as a controllable current source to supply the necessary active power to compensate for the inverter losses, to eliminate current harmonics and to compensate the reactive power. Therefore, the sinusoidal line currents are drawn from the AC source. Three control loops are used in the control scheme to obtain the constant DC-link voltage, to track the line current command and to balance the neutral-point voltage. The redundant operating states in the adopted inverter can be selected to compensate the clamped capacitor voltage. A mathematical model of the proposed inverter for an active power filter is derived and the control scheme provided. Simulations and experiments based on a laboratory scale-down prototype are presented to verify the effectiveness of the proposed control scheme.

[1]  Juan W. Dixon,et al.  A simple and low-cost control strategy for active power filters connected in cascade , 1997, IEEE Trans. Ind. Electron..

[2]  Fang Zheng Peng,et al.  Multilevel inverters: a survey of topologies, controls, and applications , 2002, IEEE Trans. Ind. Electron..

[3]  Akira Sagawa,et al.  Optimal-regulator-based control of NPC boost rectifiers for unity power factor and reduced neutral-point-potential variations , 1999, IEEE Trans. Ind. Electron..

[4]  K. K. Sen SSSC-static synchronous series compensator: theory, modeling, and application , 1998 .

[5]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[6]  Thomas A. Lipo,et al.  VSI-PWM rectifier/inverter system with a reduced switch count , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[7]  Hirofumi Akagi,et al.  A New Neutral-Point-Clamped PWM Inverter , 1981, IEEE Transactions on Industry Applications.

[8]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[9]  W. M. Grady,et al.  Survey of active power line conditioning methodologies , 1990 .

[10]  S. Datta Power pollution caused by lighting control systems , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[11]  C.O. Nwankpa,et al.  A new type of STATCOM based on cascading voltage source inverters with phase-shifted unipolar SPWM , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[12]  Arindam Ghosh,et al.  A flexible DSTATCOM operating in voltage or current control mode , 2002 .

[13]  S. S. Choi,et al.  Transformerless dynamic voltage restorer , 2002 .

[14]  Fang Zheng Peng,et al.  Multilevel converters-a new breed of power converters , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[15]  Boon-Teck Ooi,et al.  UPFC using multiconverter operated by phase-shifted triangle carrier SPWM strategy , 1998 .