Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1).

[1]  Hongying Zhu,et al.  Optical imaging techniques for point-of-care diagnostics. , 2013, Lab on a chip.

[2]  Matt Trau,et al.  μ-eLCR: a microfabricated device for electrochemical detection of DNA base changes in breast cancer cell lines. , 2013, Lab on a chip.

[3]  P P Freitas,et al.  Spintronic platforms for biomedical applications. , 2012, Lab on a chip.

[4]  Wouter van der Wijngaart,et al.  Biocompatible "click" wafer bonding for microfluidic devices. , 2012, Lab on a chip.

[5]  A. Griffiths,et al.  High-resolution dose–response screening using droplet-based microfluidics , 2011, Proceedings of the National Academy of Sciences of the United States of America.

[6]  E. Delamarche,et al.  Capillary pumps for autonomous capillary systems. , 2007, Lab on a chip.

[7]  Ali Kemal Yetisen,et al.  Paper-based microfluidic point-of-care diagnostic devices. , 2013, Lab on a chip.

[8]  Mark Burns,et al.  Microfluidic chemical analysis systems. , 2011, Annual review of chemical and biomolecular engineering.

[9]  M. Tabrizian,et al.  Microfluidic designs and techniques using lab-on-a-chip devices for pathogen detection for point-of-care diagnostics. , 2012, Lab on a chip.

[10]  David Juncker,et al.  Capillarics: pre-programmed, self-powered microfluidic circuits built from capillary elements. , 2013, Lab on a chip.

[11]  Patrick Tabeling,et al.  Wettability patterning by UV-initiated graft polymerization of poly(acrylic acid) in closed microfluidic systems of complex geometry. , 2010, Analytical chemistry.

[12]  R. Zengerle,et al.  Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. , 2010, Chemical Society reviews.

[13]  Mohammad Faghri,et al.  A fluidic diode, valves, and a sequential-loading circuit fabricated on layered paper. , 2012, Lab on a chip.

[14]  L. Gervais,et al.  Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. , 2009, Lab on a chip.

[15]  Chad A Mirkin,et al.  A microfluidic detection system based upon a surface immobilized biobarcode assay. , 2009, Biosensors & bioelectronics.

[16]  Samuel K Sia,et al.  Commercialization of microfluidic point-of-care diagnostic devices. , 2012, Lab on a chip.

[17]  S. Doak,et al.  Highly sensitive covalently functionalised integrated silicon nanowire biosensor devices for detection of cancer risk biomarker. , 2014, Biosensors & bioelectronics.

[18]  V. Chu,et al.  Detection of ochratoxin A in wine and beer by chemiluminescence-based ELISA in microfluidics with integrated photodiodes , 2013 .

[19]  Elain Fu,et al.  Two-dimensional paper networks: programmable fluidic disconnects for multi-step processes in shaped paper. , 2011, Lab on a chip.

[20]  James F Rusling,et al.  Ultrasensitive detection of cancer biomarkers in the clinic by use of a nanostructured microfluidic array. , 2012, Analytical chemistry.

[21]  João Pedro Conde,et al.  Control of sequential fluid delivery in a fully autonomous capillary microfluidic device. , 2013, Lab on a chip.

[22]  R. Kamm,et al.  Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function , 2012, Proceedings of the National Academy of Sciences.

[23]  Robert Langer,et al.  A vector-free microfluidic platform for intracellular delivery , 2013, Proceedings of the National Academy of Sciences.

[24]  Maribel E Funes-Huacca,et al.  Antimicrobial susceptibility assays in paper-based portable culture devices. , 2014, Lab on a chip.

[25]  C. Ahn,et al.  An innovative sample-to-answer polymer lab-on-a-chip with on-chip reservoirs for the POCT of thyroid stimulating hormone (TSH) , 2013, 2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS).

[26]  João Pedro Conde,et al.  Microspot-based ELISA in microfluidics: chemiluminescence and colorimetry detection using integrated thin-film hydrogenated amorphous silicon photodiodes. , 2011, Lab on a chip.