Experimental Study of Combustible and Non-combustible Construction in a Natural Fire

With the adoption of performance-based fire design and the development of new engineered wood products, wood-based mid-rise and high-rise buildings are beginning to be constructed all around the globe. This trend has accelerated efforts to gain more understanding of the risks associated with combustible construction. To compare the differences between combustible and non-combustible construction, a series of full scale fire tests was conducted at Carleton University, the results of which are presented in this paper. These tests represented real bedroom fires with different room construction types: cross laminated timber (CLT) construction, light timber frame construction and light steel frame construction. Results showed that gypsum boards provided a better protection to CLT panels than to light frame walls. Compared with fires in the protected rooms, fire in the unprotected CLT room during the fully developed phase showed accelerated fire development and resulted in over 80% higher total heat release rate (THRR) but slightly lower room temperatures, and external burning contributed to about 64% of the THRR. It was also found that the light timber frame walls and light steel frame walls behaved very differently in the real fire. Furthermore, higher charring rates in both the unprotected CLT panels (1.0 mm/min) and wood studs (1.2 mm/min) were obtained in the real fire than those in the standard fire.

[1]  Craig L. Beyler,et al.  Carbon Monoxide Production in Compartment Fires , 1992 .

[2]  Andrea Frangi,et al.  Fire Performance of Timber Structures under Natural Fire Conditions , 2005 .

[3]  William M. Pitts,et al.  Carbon Monoxide Production in Compartment Fires: Reduced-Scale Enclosure Test Facility (NISTIR 5568) , 1994 .

[4]  George Hadjisophocleous,et al.  Instrumentation Design for HRR Measurements in a Large-Scale Fire Facility , 2011 .

[6]  S. Gagnon,et al.  CLT handbook : cross-laminated timber , 2011 .

[7]  James G. Quintiere,et al.  Enclosure Fire Dynamics , 1999 .

[8]  Samuel L. Manzello,et al.  Real fire performance of partition assemblies , 2005 .

[9]  Andrea Frangi,et al.  Natural Full-Scale Fire Test on a 3 Storey XLam Timber Building , 2008 .

[10]  Minjuan He,et al.  Very tall wooden buildings with cross laminated timber , 2011 .

[11]  Yong Wang,et al.  Structural behaviour of cold-formed thin-walled short steel channel columns at elevated temperatures. Part 1: experiments , 2003 .

[12]  A Kashef,et al.  Survey Results of Combustible Contents and Floor Areas in Canadian Multi-Family Dwellings , 2011 .

[13]  Jonathan F Nyman Equivalent Fire Resistance Ratings of Construction Elements Exposed to Realistic Fires , 2002 .

[14]  C. R. Barnett A New T-equivalent Method for Fire Rated Wall Constructions using Cumulative Radiation Energy: , 2007 .

[15]  Hao C. Tran,et al.  Data Reduction of Room Tests for Zone Model Validation , 1992 .

[16]  Andrew H. Buchanan,et al.  Predicting Fire Resistance Performance of Drywall Construction Exposed to Parametric Design Fires — A Review: , 2008 .

[17]  Samuel L. Manzello,et al.  Influence of gypsum board type (X or C) on real fire performance of partition assemblies , 2007 .

[19]  K. W. Ragland,et al.  Wood ash composition as a function of furnace temperature , 1993 .

[20]  Mohamed A. Sultan A model for predicting heat transfer through noninsulated unloaded steel-stud gypsum board wall assemblies exposed to fire , 1996 .

[21]  K. W. Ragland,et al.  Properties of wood for combustion analysis. , 1991 .

[22]  William M Pitts Carbon monoxide production in compartment fires: : reduced-scale enclosure test facility , 1994 .

[23]  Danny Hopkin,et al.  Full-scale natural fire tests on gypsum lined structural insulated panel (SIP) and engineered floor , 2011 .

[24]  Thomas Lennon,et al.  The natural fire safety concept—full-scale tests at Cardington , 2003 .

[25]  Bevan Jones,et al.  Performance of Gypsum Plasterboard Assemblies Exposed to Real Building Fires , 2001 .

[26]  Samuel L. Manzello,et al.  Performance of a non‐load‐bearing steel stud gypsum board wall assembly: Experiments and modelling , 2007 .

[27]  Joo-Saeng Park,et al.  Fire Resistance of Light-framed Wood Floors Exposed to Real and Standard Fire , 2004 .

[28]  R. B. Williamson,et al.  Compartment fire near-field entrainment measurements , 1995 .

[29]  Javier Trelles,et al.  CFD Investigation of Large Scale Pallet Stack Fires in Tunnels Protected by Water Mist Systems , 2010 .

[30]  Andrea Frangi,et al.  Fire behaviour of cross-laminated solid timber panels , 2008 .

[31]  Tuula Hakkarainen,et al.  Post-Flashover Fires in Light and Heavy Timber Construction Compartments , 2002 .

[32]  Cameron McGregor Contribution of cross laminated timber panels to room fires , 2013 .

[33]  Andrea Frangi,et al.  Experimental analysis of cross-laminated timber panels in fire , 2009 .