Experimental Study of Combustible and Non-combustible Construction in a Natural Fire
暂无分享,去创建一个
Xia Zhang | Xiao Li | George Hadjisophocleous | Cameron McGregor | G. Hadjisophocleous | Xiao Li | Xia Zhang | Cameron McGregor
[1] Craig L. Beyler,et al. Carbon Monoxide Production in Compartment Fires , 1992 .
[2] Andrea Frangi,et al. Fire Performance of Timber Structures under Natural Fire Conditions , 2005 .
[3] William M. Pitts,et al. Carbon Monoxide Production in Compartment Fires: Reduced-Scale Enclosure Test Facility (NISTIR 5568) , 1994 .
[4] George Hadjisophocleous,et al. Instrumentation Design for HRR Measurements in a Large-Scale Fire Facility , 2011 .
[6] S. Gagnon,et al. CLT handbook : cross-laminated timber , 2011 .
[7] James G. Quintiere,et al. Enclosure Fire Dynamics , 1999 .
[8] Samuel L. Manzello,et al. Real fire performance of partition assemblies , 2005 .
[9] Andrea Frangi,et al. Natural Full-Scale Fire Test on a 3 Storey XLam Timber Building , 2008 .
[10] Minjuan He,et al. Very tall wooden buildings with cross laminated timber , 2011 .
[11] Yong Wang,et al. Structural behaviour of cold-formed thin-walled short steel channel columns at elevated temperatures. Part 1: experiments , 2003 .
[12] A Kashef,et al. Survey Results of Combustible Contents and Floor Areas in Canadian Multi-Family Dwellings , 2011 .
[13] Jonathan F Nyman. Equivalent Fire Resistance Ratings of Construction Elements Exposed to Realistic Fires , 2002 .
[14] C. R. Barnett. A New T-equivalent Method for Fire Rated Wall Constructions using Cumulative Radiation Energy: , 2007 .
[15] Hao C. Tran,et al. Data Reduction of Room Tests for Zone Model Validation , 1992 .
[16] Andrew H. Buchanan,et al. Predicting Fire Resistance Performance of Drywall Construction Exposed to Parametric Design Fires — A Review: , 2008 .
[17] Samuel L. Manzello,et al. Influence of gypsum board type (X or C) on real fire performance of partition assemblies , 2007 .
[19] K. W. Ragland,et al. Wood ash composition as a function of furnace temperature , 1993 .
[20] Mohamed A. Sultan. A model for predicting heat transfer through noninsulated unloaded steel-stud gypsum board wall assemblies exposed to fire , 1996 .
[21] K. W. Ragland,et al. Properties of wood for combustion analysis. , 1991 .
[22] William M Pitts. Carbon monoxide production in compartment fires: : reduced-scale enclosure test facility , 1994 .
[23] Danny Hopkin,et al. Full-scale natural fire tests on gypsum lined structural insulated panel (SIP) and engineered floor , 2011 .
[24] Thomas Lennon,et al. The natural fire safety concept—full-scale tests at Cardington , 2003 .
[25] Bevan Jones,et al. Performance of Gypsum Plasterboard Assemblies Exposed to Real Building Fires , 2001 .
[26] Samuel L. Manzello,et al. Performance of a non‐load‐bearing steel stud gypsum board wall assembly: Experiments and modelling , 2007 .
[27] Joo-Saeng Park,et al. Fire Resistance of Light-framed Wood Floors Exposed to Real and Standard Fire , 2004 .
[28] R. B. Williamson,et al. Compartment fire near-field entrainment measurements , 1995 .
[29] Javier Trelles,et al. CFD Investigation of Large Scale Pallet Stack Fires in Tunnels Protected by Water Mist Systems , 2010 .
[30] Andrea Frangi,et al. Fire behaviour of cross-laminated solid timber panels , 2008 .
[31] Tuula Hakkarainen,et al. Post-Flashover Fires in Light and Heavy Timber Construction Compartments , 2002 .
[32] Cameron McGregor. Contribution of cross laminated timber panels to room fires , 2013 .
[33] Andrea Frangi,et al. Experimental analysis of cross-laminated timber panels in fire , 2009 .