A novel online stator ground-wall insulation monitoring scheme for inverter-fed AC motors

Insulation failures are one of the most common failure modes of ac motors, especially high-voltage motors. Online monitoring of insulation health of ac motors is important for preventing unexpected outages and minimizing the associated financial losses particularly in critical applications. Previously, an online ground-wall insulation monitoring technique has already been proposed for 6-lead ac motors. In this paper, a novel online ground-wall insulation monitoring scheme is proposed for inverter-fed ac motors. This approach is based on measurement of common-mode insulation leakage current for online C/DF (capacitance and dissipation factor) monitoring. The proposed technique can be applied to both 3-lead and 6-lead ac motors and can also be extended to monitor the insulation health of the cable connecting the inverter and the motor. The proposed technique is demonstrated in the lab environment, and correlated with standard offline C/DF measurements.

[1]  Sanghoon Lee,et al.  A Stator Winding Insulation Condition Monitoring Technique for Inverter-Fed Machines , 2006, IEEE Transactions on Power Electronics.

[2]  Michael J. Roemer,et al.  On-line motor winding early diagnostic based on dynamic leakage current monitoring , 2011, 2011 Aerospace Conference.

[3]  G. Ramm,et al.  New Multi-Frequency Method for the Determination of the Dissipation Factor of Capacitors and of the Time Constant of Resistors , 2004, 2004 Conference on Precision Electromagnetic Measurements.

[4]  A. von Jouanne,et al.  Multilevel inverter modulation schemes to eliminate common-mode voltages , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[5]  G.C. Stone Recent important changes in IEEE motor and generator winding insulation diagnostic testing standards , 2005, IEEE Transactions on Industry Applications.

[6]  Pinjia Zhang,et al.  Online detection of endwinding contamination in industrial motors , 2011, 2011 Electrical Insulation Conference (EIC)..

[7]  N. Zargari,et al.  Comparison and mitigation of common mode voltage in power converter topologies , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[8]  Thomas G. Habetler,et al.  Online surge testing applied to an induction machine with emulated insulation breakdown , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[9]  K Younsi,et al.  On-line capacitance and dissipation factor monitoring of AC stator insulation , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  T. G. Habetler,et al.  Experimental testing of a neural-network-based turn-fault detection scheme for induction machines under accelerated insulation failure conditions , 2003, 4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003..

[11]  G. Stone,et al.  Electrical Insulation for Rotating Machines , 2003 .

[12]  Sang Bin Lee,et al.  An Advanced Stator Winding Insulation Quality Assessment Technique for Inverter-fed Machines , 2006, Conference Record of the 2006 IEEE Industry Applications Conference Forty-First IAS Annual Meeting.

[13]  Hamid A. Toliyat,et al.  Handbook of Electric Motors , 2004 .

[14]  D.E. Schump,et al.  Testing to assure reliable operation of electric motors , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[15]  Harald Moser,et al.  New multifrequency method for the determination of the dissipation factor of capacitors and of the time constant of resistors , 2005, IEEE Transactions on Instrumentation and Measurement.

[16]  Ian Culbert,et al.  Electrical insulation for rotating machines : design, evaluation, aging, testing, and repair , 2003 .

[17]  G. Stone,et al.  Inverter-fed drives: which motor stators are at risk? , 2000 .

[18]  E. Persson,et al.  Transient effects in application of PWM inverters to induction motors , 1991, Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference.

[19]  Samir Kouro,et al.  Modeling and analysis of common-mode voltages generated in medium voltage PWM-CSI drives , 2003 .

[20]  Thomas G. Habetler,et al.  A survey of condition monitoring and protection methods for medium voltage induction motors , 2009 .

[21]  Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I , 1985, IEEE Transactions on Industry Applications.

[22]  Chanan Singh,et al.  Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part II , 1985, IEEE Transactions on Industry Applications.

[23]  Jinkyu Yang,et al.  An online groundwall and phase-to-phase insulation quality assessment technique for AC-machine stator windings , 2006, IEEE Transactions on Industry Applications.