Extensive evaluation of high performance protection relays for the Hydro-Quebec series compensated network

This paper reports on an extensive study to compare the performance of 8 preselected high performance power line protection systems on the Hydro-Quebec series compensated network. The paper first presents an evaluation of the commissioning aspects and manufacturing quality of the tested relays. It then describes the simulated network, the relay testing procedure, and the laboratory test results obtained on a modern real time power system simulator. Published results of relay performance on series compensated lines are scarce and this paper provides valuable information for utility protection engineers. A total of 115,000 network disturbances were simulated and recorded on 20 different 735 kV lines; fractional test results for 84,030 cases are presented in the paper. The approach using real time power system simulation proved to be an efficient technique for evaluating protection relay performance. The laboratory test results demonstrated that the two best protection principles to be applied on the Hydro-Quebec series compensated network are those based on current differential and segregated phase comparison. The analysis does not take into account telecommunication requirements or other external constraints. >

[1]  P. Fauquembergue,et al.  'MORGAT': a data processing program for testing transmission line protective relays , 1988 .

[2]  R. J. Marttila Performance of distance relay mho elements on MOV-protected series-compensated transmission lines , 1992 .

[3]  Mladen Kezunovic,et al.  Digital models of coupling capacitor voltage transformers for protective relay transient studies , 1992 .

[4]  Jean Claude Maun,et al.  A comprehensive hardware and software environment for development of digital protection relays , 1989 .

[5]  Jaroslaw Domaszewicz,et al.  Transients computation for relay testing in real-time , 1994 .

[6]  Ali Abur,et al.  DYNA-TEST simulator for relay testing. I. Design characteristics , 1991 .

[7]  W. W. L. Keerthipala,et al.  Improved simulation models for current and voltage transformers in relay studies , 1992 .

[8]  Kp Wong,et al.  A Computer Controlled Protection Test System , 1985 .

[9]  J. Giesbrecht,et al.  A real time digital simulator for testing relays , 1992 .

[10]  G. D. Rockefeller,et al.  A digitally-controlled, real-time, analog power-system simulator for closed-loop protective relaying testing , 1988 .

[11]  John Berdy Protection or Circuits with Series Capacitors , 1962, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[12]  G. H. Topham,et al.  Experience and problems with the protection of series compensated lines , 1989 .

[13]  Miles A Redfern,et al.  A personal computer based system for the laboratory evaluation of high performance power system protection relays , 1991 .

[14]  J. Esztergalyos,et al.  Digital model power system , 1990, IEEE Computer Applications in Power.