Open-Phase Fault-Tolerant Operation of the Three-Phase Dual Active Bridge Converter

The three-phase dual active bridge (3p-DAB) converter is widely considered in dc-grid applications. Because of the higher number of switches in the 3p-DAB, it can be argued that the reliability of the 3p-DAB is reduced when compared to other isolated-bidirectional dc–dc converter topologies. The previous work has shown that the 3p-DAB can be operated in a frozen leg fault-tolerant mode, i.e., with the two transistors of the same phase being opened by their gate driver internal protections. Because the free-wheeling diodes are left self-commutated, the analytical characterization of the converter for all voltage and loading conditions is not trivial. In this article, it is proposed to open the faulty phase such as it eliminates the interaction with the faulty-phase free-wheeling diodes. This allows the converter to fall in a characterizable operating mode for all voltage and loading conditions. The results further show that the open-phase operation provides advantages over the frozen leg operation in terms of current stress and power transfer capability. Experimental results on a small-scale closed-loop gallium nitride-based prototype as well as time-domain simulation results are provided to support the theoretical analyses.

[1]  R. D. Middlebrook,et al.  Input filter considerations in design and application of switching regulators. , 1976 .

[2]  Slobodan Cuk,et al.  A general unified approach to modelling switching-converter power stages , 1976, 1970 IEEE Power Electronics Specialists Conference.

[3]  D.M. Divan,et al.  A three-phase soft-switched high power density DC/DC converter for high power applications , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[4]  J. M. Noworolski,et al.  Generalized averaging method for power conversion circuits , 1990, 21st Annual IEEE Conference on Power Electronics Specialists.

[5]  D.M. Divan,et al.  Performance characterization of a high power dual active bridge DC/DC converter , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[6]  Thomas A. Lipo,et al.  A strategy to isolate the switching device fault of a current regulated motor drive , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[7]  F. M. Miles,et al.  Principles of fault tolerance , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[8]  D. Boroyevich,et al.  Modeling, control and stability analysis of a PEBB based DC DPS , 1999 .

[9]  George C. Verghese,et al.  Modeling and simulation of power electronic converters , 2001, Proc. IEEE.

[10]  Fred C. Lee,et al.  Impedance specifications for stable DC distributed power systems , 2002 .

[11]  Edison Roberto Cabral da Silva,et al.  Fault-tolerant voltage-fed PWM inverter AC motor drive systems , 2004, IEEE Transactions on Industrial Electronics.

[12]  T.A. Lipo,et al.  Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations , 2003, IEEE Transactions on Power Electronics.

[13]  Janusz Nieznanski,et al.  Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents , 2007, IEEE Transactions on Industrial Electronics.

[14]  Hengsi Qin,et al.  Generalized Average Modeling of Dual Active Bridge DC–DC Converter , 2012, IEEE Transactions on Power Electronics.

[15]  Rolando Burgos,et al.  Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems , 2013, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[16]  Rik W. De Doncker,et al.  Dynamic and Balanced Control of Three-Phase High-Power Dual-Active Bridge DC–DC Converters in DC-Grid Applications , 2013, IEEE Transactions on Power Electronics.

[17]  Yantao Song,et al.  Survey on Reliability of Power Electronic Systems , 2013, IEEE Transactions on Power Electronics.

[18]  P. Stefanutti,et al.  Power Electronic Traction Transformer-Low Voltage Prototype , 2013, IEEE Transactions on Power Electronics.

[19]  Enrico Santi,et al.  Comprehensive Review of Stability Criteria for DC Power Distribution Systems , 2014, IEEE Transactions on Industry Applications.

[20]  Behrooz Mirafzal,et al.  Survey of Fault-Tolerance Techniques for Three-Phase Voltage Source Inverters , 2014, IEEE Transactions on Industrial Electronics.

[21]  Rik W. De Doncker Power electronic technologies for flexible DC distribution grids , 2014 .

[22]  Wenhua Liu,et al.  Overview of Dual-Active-Bridge Isolated Bidirectional DC–DC Converter for High-Frequency-Link Power-Conversion System , 2014, IEEE Transactions on Power Electronics.

[23]  Subhashish Bhattacharya,et al.  A Transformerless Intelligent Power Substation: A three-phase SST enabled by a 15-kV SiC IGBT , 2015, IEEE Power Electronics Magazine.

[24]  Elena A. Lomonova,et al.  Performance Evaluation of a Three-Phase Dual Active Bridge DC–DC Converter With Different Transformer Winding Configurations , 2016, IEEE Transactions on Power Electronics.

[25]  Kai Zhang,et al.  Large- and Small-Signal Average-Value Modeling of Dual-Active-Bridge DC–DC Converter Considering Power Losses , 2017, IEEE Transactions on Power Electronics.

[26]  Ling Shi,et al.  Generalized averaging modeling and control strategy for three-phase dual-active-bridge DC-DC converters with three control variables , 2017, 2017 IEEE Applied Power Electronics Conference and Exposition (APEC).

[27]  Ilhan Kocar,et al.  Hybrid Average Modeling of Three-Phase Dual Active Bridge Converters for Stability Analysis , 2018, IEEE Transactions on Power Delivery.

[28]  Rik W. De Doncker,et al.  Voltage Control of Parallel-Connected Dual-Active Bridge Converters for Shipboard Applications , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[29]  Rik W. De Doncker,et al.  Operation-Oriented Design Procedure of a Three-Phase Dual-Active Bridge Converter for a Wide Operation Range , 2018, 2018 IEEE Energy Conversion Congress and Exposition (ECCE).

[30]  Marco Liserre,et al.  Failure Analysis of the dc-dc Converter: A Comprehensive Survey of Faults and Solutions for Improving Reliability , 2018, IEEE Power Electronics Magazine.

[31]  Frede Blaabjerg,et al.  Frozen Leg Operation of a Three-Phase Dual Active Bridge Converter , 2019, IEEE Transactions on Power Electronics.

[32]  Mohammad Reza Zolghadri,et al.  A Fault-Tolerant Strategy for Three-Phase Dual Active Bridge Converter , 2019, 2019 10th International Power Electronics, Drive Systems and Technologies Conference (PEDSTC).