Improved Liver R2* Mapping by Averaging Decay Curves

Liver R2* mapping is often degraded by the low signal-to-noise ratio (SNR) especially in the presence of severe iron. This study aims to improve liver R2* mapping at low SNRs by averaging decay curves before the process of curve-fitting. Independently filtering echo images by nonlocal means (NLM) demonstrated improved quality of R2* mapping, but may introduce new errors due to the nonlinear nature of the NLM filter, during which the averaging weights may vary with different image contents at multiple echo times. In addition, the image denoising effect of the NLM may decline when no sufficient similar patches are available. To overcome these drawbacks, we proposed to filter decay curves instead of images. In this novel scheme, decay curves were averaged in a local window, each with a weight assigned according to the curve-similarity measured by the distance between one of the neighboring curves and the targeted one. The proposed method was tested on simulated, phantom and patient data. The results demonstrate that the proposed method can provide more accurate R2* mapping compared with the NLM algorithm, and hence has the potential to improve diagnosis and therapy in patients with liver iron.

[1]  D. Borsook,et al.  The role of imaging , 2014, Journal of the peripheral nervous system : JPNS.

[2]  Aaron J. Miller,et al.  The use of power images to perform quantitative analysis on low SNR MR images. , 1993, Magnetic resonance imaging.

[3]  Jie Deng,et al.  A semiautomatic postprocessing of liver R2* measurement for assessment of liver iron overload. , 2012, Magnetic resonance imaging.

[4]  D. Pennell,et al.  Improved MRI R2* relaxometry of iron‐loaded liver with noise correction , 2013, Magnetic resonance in medicine.

[5]  José V. Manjón,et al.  MRI denoising using Non-Local Means , 2008, Medical Image Anal..

[6]  Xinyuan Zhang,et al.  Denoising MR Images Using Non-Local Means Filter with Combined Patch and Pixel Similarity , 2014, PloS one.

[7]  Guang-Zhong Yang,et al.  Improved pixel‐by‐pixel MRI R2* relaxometry by nonlocal means , 2014, Magnetic resonance in medicine.

[8]  J. D. Johnston Non-invasive assessment of hepatic iron stores by MRI. , 2004, Annals of clinical biochemistry.

[9]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[10]  T. Coates,et al.  MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. , 2005, Blood.

[11]  Qianjin Feng,et al.  A novel semiautomatic parenchyma extraction method for improved MRI R2* relaxometry of iron loaded liver , 2014, Journal of magnetic resonance imaging : JMRI.

[12]  Jiang Du,et al.  Ultrashort echo time imaging with bicomponent analysis , 2012, Magnetic resonance in medicine.

[13]  Dudley J Pennell,et al.  Myocardial T  *2 measurement in iron‐overloaded thalassemia: An ex vivo study to investigate optimal methods of quantification , 2008, Magnetic resonance in medicine.

[14]  D. Pennell,et al.  Myocardial T  2* measurements in iron‐overloaded thalassemia: An in vivo study to investigate optimal methods of quantification , 2008, Magnetic resonance in medicine.

[15]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[16]  Leonid P. Yaroslavsky,et al.  Digital Picture Processing , 1985 .

[17]  Dudley J Pennell,et al.  Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan , 2014, Journal of Cardiovascular Magnetic Resonance.

[18]  J. Wood,et al.  Diagnosis and management of transfusion iron overload: The role of imaging , 2007, American journal of hematology.

[19]  Yanqiu Feng,et al.  Optimal region-of-interest MRI R2* measurements for the assessment of hepatic iron content in thalassaemia major. , 2014, Magnetic resonance imaging.

[20]  C. Hillenbrand,et al.  R2* magnetic resonance imaging of the liver in patients with iron overload. , 2009, Blood.

[21]  Einar Heiberg,et al.  Validation of a new t2* algorithm and its uncertainty value for cardiac and liver iron load determination from MRI magnitude images , 2015, Magnetic resonance in medicine.

[22]  Yanqiu Feng,et al.  Rapid look‐up table method for noise‐corrected curve fitting in the r2* mapping of iron loaded liver , 2015, Magnetic resonance in medicine.

[23]  Pierrick Coupé,et al.  Author manuscript, published in "Journal of Magnetic Resonance Imaging 2010;31(1):192-203" DOI: 10.1002/jmri.22003 Adaptive Non-Local Means Denoising of MR Images with Spatially Varying Noise Levels , 2010 .

[24]  M. Kami,et al.  Hepatic iron concentration and total body iron stores in thalassemia major. , 2000, The New England journal of medicine.

[25]  Maria Domenica Cappellini,et al.  Italian Society of Hematology practice guidelines for the management of iron overload in thalassemia major and related disorders , 2008, Haematologica.

[26]  L. P. I︠A︡roslavskiĭ Digital picture processing : an introduction , 1985 .

[27]  Jean-Michel Morel,et al.  A Review of Image Denoising Algorithms, with a New One , 2005, Multiscale Model. Simul..

[28]  Massimo Midiri,et al.  Improved T2* assessment in liver iron overload by magnetic resonance imaging. , 2009, Magnetic resonance imaging.

[29]  T. Coates,et al.  Improved R2* measurements in myocardial iron overload , 2006, Journal of magnetic resonance imaging : JMRI.

[30]  R. Lindeman,et al.  Australian guidelines for the assessment of iron overload and iron chelation in transfusion‐dependent thalassaemia major, sickle cell disease and other congenital anaemias , 2011, Internal medicine journal.

[31]  Wei Liu,et al.  Ultrashort T  2* relaxometry for quantitation of highly concentrated superparamagnetic iron oxide (SPIO) nanoparticle labeled cells , 2009, Magnetic resonance in medicine.

[32]  Olaf Dietrich,et al.  T2 measurement in articular cartilage: Impact of the fitting method on accuracy and precision at low SNR , 2009, Magnetic resonance in medicine.

[33]  T. S. St. Pierre,et al.  Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance. , 2005, Blood.

[34]  D N Firmin,et al.  Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. , 2001, European heart journal.

[35]  S. Reeder,et al.  Multipeak fat‐corrected complex R2* relaxometry: Theory, optimization, and clinical validation , 2013, Magnetic resonance in medicine.

[36]  P. Storey,et al.  Relaxivity‐iron calibration in hepatic iron overload: Predictions of a Monte Carlo model , 2015, Magnetic resonance in medicine.

[37]  Orpheus Kolokythas,et al.  A simulation-based comparison of two methods for determining relaxation rates from relaxometry images. , 2011, Magnetic resonance imaging.

[38]  C. Stein Estimation of the Mean of a Multivariate Normal Distribution , 1981 .

[39]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .