Sol–gel immobilized room-temperature phosphorescent metal-chelate as luminescent oxygen sensing material

Abstract The chelate formed by 8-hydroxy-7-iodo-5-quinolinesulfonic acid (ferron) with aluminium exhibits strong room-temperature phosphorescence (RTP) when retained on a solid support. In a previous paper we have found that sol–gel technology is a very useful approach for developing RTP optical sensors as a new way to immobilize lumiphors. Sol–gel active phases proved to exhibit a high physical rigidity that enhanced relative RTP intensities and triplet lifetimes of the immobilized probe. In this paper we present an optical sensing phase prepared using the Al–ferron chelate which displays RTP entrapped in a sol–gel glass matrix for the determination of very low levels of oxygen both dissolved in water and organic solvents and in gaseous media. The sol–gel sensing material has proved to be chemically stable for at least 6 months under ambient storage conditions. Besides a high reproducibility in the formation of the sensing materials and no leaching or bleaching of the trapped reagent (neither in the gas phase nor in water or organic solvents) was observed. Oxygen was determined by continuous flow and flow injection methods using both intensity and triplet lifetime measurements. Both methods provided a fast response, good reproducibility and detection limits of 0.0005% (v/v) in the gas phase and

[1]  R. J. Hurtubise,et al.  Dynamic and Solid-Matrix Quenching by Moisture in Solid-Matrix Phosphorescence with Filter Paper , 1994 .

[2]  Mohd Nasir Taib,et al.  Solid-state instruments for optical fibre chemical sensors. A review , 1995 .

[3]  A. Sanz-Medel,et al.  Spectrofluorimetric optosensing of aluminium in a flow injection system: determination of aluminium in dialysis fluids and concentrates , 1990 .

[4]  S. Schulman Molecular luminescence spectroscopy : methods and applications , 1985 .

[5]  J. Lovelock Ionization Methods for the Analysis of Gases and Vapors , 1961 .

[6]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[7]  C. Brinker Sol-gel science , 1990 .

[8]  Jing Chen,et al.  Model for the Moisture Quenching of Solid-Matrix Phosphorescence via the Young's Modulus of Filter Paper , 1995 .

[9]  J. Vanderkooi,et al.  A new method for measuring oxygen concentration in biological systems. , 1986, Advances in experimental medicine and biology.

[10]  Chris W. Brown,et al.  Sol-gel glass as a matrix for chemical and biochemical sensing , 1997 .

[11]  Colette McDonagh,et al.  Dissolved oxygen sensor based on fluorescence quenching of oxygen-sensitive ruthenium complexes immobilized in sol–gel-derived porous silica coatings , 1996 .

[12]  J. Demas,et al.  Oxygen sensors based on luminescence quenching: interactions of metal complexes with the polymer supports. , 1994, Analytical chemistry.

[13]  Max E. Lippitsch,et al.  Luminescence Quenching Behavior of an Oxygen Sensor Based on a Ru(II) Complex Dissolved in Polystyrene , 1995 .

[14]  Marc J.P. Leiner,et al.  Luminescence chemical sensors for biomedical applications: scope and limitations , 1991 .

[15]  Alfredo Sanz-Medel,et al.  Evaluation of some immobilized room-temperature phosphorescent metal chelates as sensing materials for oxygen , 1994 .

[16]  Ichiro Okura,et al.  Porphyrin-doped sol-gel glass as a probe for oxygen sensing , 1997 .

[17]  Yi-ming Liu,et al.  Solid-surface room-temperature phosphorescence optosensing in continuous flow systems: an approach for ultratrace metal ion determination , 1991 .

[18]  M. Hitchman,et al.  Measurement of Dissolved Oxygen , 1978 .

[19]  Max E. Lippitsch,et al.  Fibre-optic oxygen sensor with the fluorescence decay time as the information carrier , 1988 .