Accuracy and interobserver reliability of scalp ictal EEG

We studied the accuracy and reliability of scalp ictal EEG in 137 complex partial seizures (119 temporal and 18 extratemporal) in 35 patients in whom we knew the correct site of seizure origin because all patients had been seizure-free for more than 2 years after seizure surgery. Three electroencephalographers independently determined side of seizure origin based on activity at onset of electrographic seizure (ASO), rhythmic theta and alpha (RTA), postictal findings (PIF), and the electrographic seizure as a whole. When all seizures were analyzed, including those with generalized features or obscured by artifact, we determined side of seizure onset correctly in 76% to 83% of temporal seizures and 47% to 65% of extratemporal seizures. In most of the remainder, a lateralization judgment was impossible. When analysis was confined to those seizures in which lateralization was possible, we correctly lateralized 93% to 99% of temporal seizures and 89% to 100% of extratemporal seizures. Interobserver reliability was excellent. RTA and PIF were more accurate than ASO. RTA was significantly more common in temporal seizures. Our data indicate that lateralization by scalp EEG is highly accurate and reliable.

[1]  L F Quesney,et al.  False lateralization by surface EEG of seizure onset in patients with temporal lobe epilepsy and gross focal cerebral lesions , 1987, Annals of neurology.

[2]  L. Koran,et al.  The reliability of clinical methods, data and judgments (second of two parts). , 1975, The New England journal of medicine.

[3]  Jacob Cohen A Coefficient of Agreement for Nominal Scales , 1960 .

[4]  C. Ajmone‐Marsan,et al.  The epileptic seizure, its functional morphology and diagnostic significance : a clinical-electrographic analysis of metrazol-induced attacks , 1957 .

[5]  T. Rasmussen,et al.  The clinical differentiation of seizures arising in the parasagittal and anterolaterodorsal frontal convexities. , 1990, Archives of neurology.

[6]  W T Blume,et al.  The postictal electroencephalogram. , 1988, Electroencephalography and clinical neurophysiology.

[7]  D. Spencer,et al.  Reliability and accuracy of localization by scalp ictal EEG , 1985, Neurology.

[8]  T. Walczak,et al.  Scalp EEG differs in temporal and extratemporal complex partial seizures , 1991 .

[9]  T. Walczak,et al.  Temporal Lobectomy and Independent Bitemporal Interictal Activity: What Degree of Lateralization Is Sufficient? , 1991, Epilepsia.

[10]  P. Gloor,et al.  Results of surgical treatment in patients with bitemporal epileptiform abnormalities , 1989, Annals of neurology.

[11]  H. Gastaut So-called "Psychomotor" and "Temporal" Epilepsy. - A CRITICAL STUDY - , 1953 .

[12]  T. Babb,et al.  A Comparison of EEG Seizure Patterns Recorded with Surface and Depth Electrodes in Patients with Temporal Lobe Epilepsy , 1976, Epilepsia.

[13]  W. Blume,et al.  EEG morphology of partial epileptic seizures. , 1984, Electroencephalography and clinical neurophysiology.