Validation of biomechanical deformable image registration in the abdomen, thorax, and pelvis in a commercial radiotherapy treatment planning system

Purpose The accuracy of deformable image registration tools can vary widely between imaging modalities and specific implementations of the same algorithms. A biomechanical model‐based algorithm initially developed in‐house at an academic institution was translated into a commercial radiotherapy treatment planning system and validated for multiple imaging modalities and anatomic sites. Methods Biomechanical deformable registration (morfeus) is a geometry‐driven algorithm based on the finite element method. Boundary conditions are derived from the model‐based segmentation of controlling structures in each image which establishes a point‐to‐point surface correspondence. For each controlling structure, material properties and fixed or sliding interfaces are assigned. The displacements of internal volumes for controlling structures and other structures implicitly deformed are solved with finite element analysis. Registration was performed for 74 patients with images (mean vector resolution) of thoracic and abdominal 4DCT (2.8 mm) and MR (5.3 mm), liver CT‐MR (4.5 mm), and prostate MR (2.6 mm). Accuracy was quantified between deformed and actual target images using distance‐to‐agreement (DTA) for structure surfaces and the target registration error (TRE) for internal point landmarks. Results The results of the commercial implementation were as follows. The mean DTA was ≤ 1.0 mm for controlling structures and 1.0–3.5 mm for implicitly deformed structures on average. TRE ranged from 2.0 mm on prostate MR to 5.1 mm on lung MR on average, within 0.1 mm or lower than the image voxel sizes. Accuracy was not overly sensitive to changes in the material properties or variability in structure segmentations, as changing these inputs affected DTA and TRE by ≤ 0.8 mm. Maximum DTA > 5 mm occurred for 88% of the structures evaluated although these were within the inherent segmentation uncertainty for 82% of structures. Differences in accuracy between the commercial and in‐house research implementations were ≤ 0.5 mm for mean DTA and ≤ 0.7 mm for mean TRE. Conclusions Accuracy of biomechanical deformable registration evaluated on a large cohort of images in the thorax, abdomen and prostate was similar to the image voxel resolution on average across multiple modalities. Validation of this treatment planning system implementation supports biomechanical deformable registration as a versatile clinical tool to enable accurate target delineation at planning and treatment adaptation.

[1]  K. Brock,et al.  Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue. , 2006, International journal of radiation oncology, biology, physics.

[2]  K. Brock,et al.  Accuracy of finite element model-based multi-organ deformable image registration. , 2005, Medical physics.

[3]  J. Schnabel,et al.  Factors influencing the accuracy of biomechanical breast models. , 2006, Medical physics.

[4]  Jean-François Ganghoffer,et al.  Finite element simulation of interactions between pelvic organs: predictive model of the prostate motion in the context of radiotherapy. , 2009, Journal of biomechanics.

[5]  Jinkoo Kim,et al.  A finite element method to correct deformable image registration errors in low-contrast regions , 2012, Physics in medicine and biology.

[6]  Jon-Paul Voroney,et al.  Prospective comparison of computed tomography and magnetic resonance imaging for liver cancer delineation using deformable image registration. , 2006, International journal of radiation oncology, biology, physics.

[7]  Y Chi,et al.  A material sensitivity study on the accuracy of deformable organ registration using linear biomechanical models. , 2006, Medical physics.

[8]  H. Hricak,et al.  Semi‐automatic deformable registration of prostate MR images to pathological slices , 2010, Journal of Magnetic Resonance Imaging.

[9]  Adil Al-Mayah,et al.  Deformable modeling of human liver with contact surface , 2009, 2009 IEEE Toronto International Conference Science and Technology for Humanity (TIC-STH).

[10]  W. O'Dell,et al.  Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images. , 2004, Medical physics.

[11]  Titania Juang,et al.  Utility and validation of biomechanical deformable image registration in low-contrast images. , 2015, Practical radiation oncology.

[12]  Michael Velec,et al.  A novel technique to enable experimental validation of deformable dose accumulation. , 2012, Medical physics.

[13]  K. Brock,et al.  Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132 , 2017, Medical physics.

[14]  Michael Velec,et al.  A hybrid biomechanical intensity based deformable image registration of lung 4DCT. , 2015, Physics in medicine and biology.

[15]  Anders Logg,et al.  Automated Solution of Differential Equations by the Finite Element Method: The FEniCS Book , 2012 .

[16]  Masoom A Haider,et al.  Development of multiorgan finite element-based prostate deformation model enabling registration of endorectal coil magnetic resonance imaging for radiotherapy planning. , 2007, International journal of radiation oncology, biology, physics.

[17]  David Thwaites,et al.  The evaluation of a deformable image registration segmentation technique for semi-automating internal target volume (ITV) production from 4DCT images of lung stereotactic body radiotherapy (SBRT) patients. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  David A Jaffray,et al.  Accuracy and sensitivity of finite element model-based deformable registration of the prostate. , 2008, Medical physics.

[19]  Adil Al-Mayah,et al.  Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapy. , 2011, Physics in medicine and biology.

[20]  Stina Svensson,et al.  The ANACONDA algorithm for deformable image registration in radiotherapy. , 2014, Medical physics.

[21]  Titania Juang,et al.  On the need for comprehensive validation of deformable image registration, investigated with a novel 3-dimensional deformable dosimeter. , 2013, International journal of radiation oncology, biology, physics.

[22]  Quan Chen,et al.  Objective assessment of deformable image registration in radiotherapy: a multi-institution study. , 2007, Medical physics.

[23]  Anders Logg,et al.  DOLFIN: Automated finite element computing , 2010, TOMS.

[24]  Michael Velec,et al.  Accumulated Delivered Dose Response of Stereotactic Body Radiation Therapy for Liver Metastases. , 2015, International journal of radiation oncology, biology, physics.

[25]  K. Brock Results of a multi-institution deformable registration accuracy study (MIDRAS). , 2010, International journal of radiation oncology, biology, physics.

[26]  J Moseley,et al.  Sliding characteristic and material compressibility of human lung: parametric study and verification. , 2009, Medical physics.

[27]  Andrew Bayley,et al.  Rectal motion in patients receiving preoperative radiotherapy for carcinoma of the rectum. , 2011, International journal of radiation oncology, biology, physics.

[28]  Alexandra Rink,et al.  Dosimetric feasibility of ablative dose escalated focal monotherapy with MRI-guided high-dose-rate (HDR) brachytherapy for prostate cancer. , 2017, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[29]  Indrin J Chetty,et al.  Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting. , 2014, Medical physics.

[30]  Jenny Lee,et al.  Validation of Image Registration , 2016 .