Wind turbine contribution in frequency drop mitigation - modified operation and estimating released supportive energy

Wind energy high penetration levels in power systems require robust and practical operation algorithms to maintain and improve the present conventional systems performance. Thus, several studies consider the impact of wind farms installation on grid frequency, especially during frequency drops. The proposed algorithm makes the wind turbine provide promising support during frequency deviations through two operation modes, namely, normal and support. Normal mode controls wind turbine output by adjusting rotational speed and pitch angle according to the incident wind speed category. Novel normal operation secures wind turbine positive contribution in frequency deviations curtailment regardless of poor accompanying wind speed conditions. The innovative concept of merging pitch de-loading and rotational speed overproduction deceleration is implemented to avoid continuous de-loading; hence wasted wind energy is reduced. Wind turbine generator is overloaded when frequency drop occurs during high wind speed. Major algorithm parameters are tuned based on wind turbine specifications and dominant wind speed conditions at wind turbine location. The amount of supportive excess energy during frequency deviation clearance is estimated at different wind speed circumstances, including serious wind speed drop events. An islanded medium capacity hypothetical benchmark system is implemented to examine the proposed algorithm through MATLAB and Simulink simulation environments.

[1]  Raja Ayyanar,et al.  Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems , 2011, 2011 IEEE Power and Energy Society General Meeting.

[2]  Le-Ren Chang-Chien,et al.  Strategies for Operating Wind Power in a Similar Manner of Conventional Power Plant , 2009, IEEE Transactions on Energy Conversion.

[3]  J.A.P. Lopes,et al.  Participation of Doubly Fed Induction Wind Generators in System Frequency Regulation , 2007, IEEE Transactions on Power Systems.

[4]  Vijay Vittal,et al.  Impact of increased penetration of DFIG based wind turbine generators on transient and small signal stability of power systems , 2009, IEEE PES General Meeting.

[5]  I. A. Gowaid,et al.  Improved inertia and frequency support from grid-connected DFIG wind farms , 2011, 2011 IEEE/PES Power Systems Conference and Exposition.

[6]  H. Banakar,et al.  Kinetic Energy of Wind-Turbine Generators for System Frequency Support , 2009, IEEE Transactions on Power Systems.

[7]  Jacob Ostergaard,et al.  Variable speed wind turbines capability for temporary over-production , 2009, 2009 IEEE Power & Energy Society General Meeting.

[8]  Wei-Ting Lin,et al.  Enhancing Frequency Response Control by DFIGs in the High Wind Penetrated Power Systems , 2011, IEEE Transactions on Power Systems.

[9]  T. Thiringer,et al.  Temporary Primary Frequency Control Support by Variable Speed Wind Turbines— Potential and Applications , 2008, IEEE Transactions on Power Systems.

[10]  M. Kayikci,et al.  Dynamic Contribution of DFIG-Based Wind Plants to System Frequency Disturbances , 2009, IEEE Transactions on Power Systems.

[11]  Mohsen Faridi,et al.  Pitch control of wind turbine blades in noisy and unstable wind conditions , 2010, 2010 9th International Conference on Environment and Electrical Engineering.