Cultivation of Saccharomyces cerevisiae with Feedback Regulation of Glucose Concentration Controlled by Optical Fiber Glucose Sensor

Glucose belongs among the most important substances in both physiology and industry. Current food and biotechnology praxis emphasizes its on-line continuous monitoring and regulation. These provoke increasing demand for systems, which enable fast detection and regulation of deviations from desired glucose concentration. We demonstrated control of glucose concentration by feedback regulation equipped with in situ optical fiber glucose sensor. The sensitive layer of the sensor comprises oxygen-dependent ruthenium complex and preimmobilized glucose oxidase both entrapped in organic–inorganic polymer ORMOCER®. The sensor was placed in the laboratory bioreactor (volume 5 L) to demonstrate both regulations: the control of low levels of glucose concentrations (0.4 and 0.1 mM) and maintenance of the glucose concentration (between 2 and 3.5 mM) during stationary phase of cultivation of Saccharomyces cerevisiae. Response times did not exceed 6 min (average 4 min) with average deviation of 4%. Due to these regulation characteristics together with durable and long-lasting (≥2 month) sensitive layer, this feedback regulation system might find applications in various biotechnological processes such as production of low glucose content beverages.

[1]  Peter Panjan,et al.  A fully online sensor‐equipped, disposable multiphase microbioreactor as a screening platform for biotechnological applications , 2018, Biotechnology and bioengineering.

[2]  Maria Lepore,et al.  Determination of Different Saccharides Concentration by Means of a Multienzymes Amperometric Biosensor , 2017, J. Sensors.

[3]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[4]  Abbas Barfidokht,et al.  Electrochemical glucose sensors in diabetes management: an updated review (2010-2020). , 2020, Chemical Society reviews.

[5]  Yang Hao,et al.  Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels , 2019, Diagnostics.

[6]  Peter Panjan,et al.  Towards microbioprocess control: an inexpensive 3D printed microbioreactor with integrated online real-time glucose monitoring. , 2018, The Analyst.

[7]  O. Wolfbeis,et al.  Fiber-Optic Chemical Sensors and Biosensors (2015-2019). , 2020, Analytical chemistry.

[8]  Patricia Scully,et al.  Optical fibre biosensors using enzymatic transducers to monitor glucose , 2007 .

[9]  Melody M. Anderson,et al.  Continuous glucose monitoring and control in a rotating wall perfused bioreactor , 2004, Biotechnology and bioengineering.

[10]  Chinnu Sabu,et al.  Advanced biosensors for glucose and insulin. , 2019, Biosensors & bioelectronics.

[11]  O. Wolfbeis Fiber-optic chemical sensors and biosensors. , 2004, Analytical chemistry.

[12]  Shreyas Sen,et al.  EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing , 2019, Sensors.

[13]  S. Noack,et al.  A FRET-based biosensor for the quantification of glucose in culture supernatants of mL scale microbial cultivations , 2019, Microbial Cell Factories.

[14]  Antonio Baldi,et al.  Electrochemical Paper-Based Biosensor Devices for Rapid Detection of Biomarkers , 2020, Sensors.

[15]  M. Přibyl,et al.  Analytical characteristics of a glucose sensor with an optical oxygen transducer for the monitoring of biotechnological processes , 2018, Measurement Science and Technology.

[16]  O. Wolfbeis,et al.  Fiber-Optic Chemical Sensors and Biosensors (2013-2015). , 2016, Analytical chemistry.

[17]  S. Dzyadevych,et al.  Hybrid coatings as transducers in optical biosensors , 2008 .

[18]  J. D. Wilson,et al.  Glucose: Detection and analysis. , 2015, Food chemistry.

[19]  Benjamin Potelon,et al.  Concentration Measurement of Microliter-Volume Water–Glucose Solutions Using $Q$ Factor of Microwave Sensors , 2019, IEEE Transactions on Instrumentation and Measurement.

[20]  O. Wolfbeis,et al.  Fiber-optic chemical sensors and biosensors (2008-2012). , 2013, Analytical chemistry.

[21]  S. Adeloju,et al.  Amperometric detection of glucose in fruit juices with polypyrrole-based biosensor with an integrated permselective layer for exclusion of interferences. , 2017, Food chemistry.

[22]  Ala Eldin Omer,et al.  Low-cost portable microwave sensor for non-invasive monitoring of blood glucose level: novel design utilizing a four-cell CSRR hexagonal configuration , 2020, Scientific Reports.

[23]  S. Clarke,et al.  A history of blood glucose meters and their role in self-monitoring of diabetes mellitus , 2012, British journal of biomedical science.

[24]  S. Wölfl,et al.  Optical biosensor optimized for continuous in-line glucose monitoring in animal cell culture , 2017, Analytical and Bioanalytical Chemistry.