New Ideas for a Soft Synchronizer Applied to CHP Cogeneration

This paper provides new ideas for the synchronization between an electric power system and a synchronous generator. If an individual ac generator is to be operated with another ac power system, the synchronization is an essential process for the parallel operation. For small combined heat and power cogeneration, the synchronization is a very frequent event and one of the most important jobs in daily operation. There are several types of traditional devices that support or control the breaker closure within the synchronizing criteria. However, the actual break closing is not controlled exactly on a zero point phase-angle difference. In this paper, we introduce new ideas that will lead two ac systems to a smooth and soft synchronization. With these ideas, a soft synchronizer that provides the perfect phase-angle matching is realized. To verify the effectiveness of this newly proposed soft synchronizer, we had conducted simulation studies using MATLAB as well as experimental tests with an actual synchronous diesel generator.

[1]  J.V. Mitsche,et al.  Shaft Torsional Stress Due to Asynchronous Faulty Synchronization , 1980, IEEE Transactions on Power Apparatus and Systems.

[2]  R.H. Lasseter Extended CERTS microgrid , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[3]  K. Yeager Striving for Power Perfection , 2008, IEEE Power and Energy Magazine.

[4]  C. Anderson,et al.  Generator Black Start Validation Using Synchronized Phasor Measurement , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[5]  K. E. Yeager,et al.  Modeling of emergency diesel generators in an 800 megawatt nuclear power plant , 1993 .

[6]  Goran Strbac,et al.  Policymaking for microgrids , 2008, IEEE Power and Energy Magazine.

[7]  G. Venkataramanan,et al.  Optimal Technology Selection and Operation of Commercial-Building Microgrids , 2008, IEEE Transactions on Power Systems.

[8]  Peter W. Lehn,et al.  A Block Diagram Approach to Reference Frame Transformation of Converter Dynamic Models , 2006, 2006 Canadian Conference on Electrical and Computer Engineering.

[9]  G. Benmouyal,et al.  Synchronized phasor measurement in protective relays for protection, control, and analysis of electric power systems , 2004, 57th Annual Conference for Protective Relay Engineers, 2004.

[10]  R.A. Evans A manual/automatic synchronization circuit for a 37.5 MVA steam turbine driven generator , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[11]  L. Chang,et al.  A new method for three-phase voltage detection and protection based on reference frame transformation , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[12]  D. W. Smaha,et al.  Generator synchronizing industry survey results , 1996 .

[13]  Chih-Wen Liu,et al.  A precise calculation of power system frequency and phasor , 2000 .

[14]  N.T. Stringer Voltage considerations during generator synchronizing , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[15]  P. Djurić,et al.  Frequency tracking in power networks in the presence of harmonics , 1993 .

[16]  T. Sezi A new method for measuring power system frequency , 1999, 1999 IEEE Transmission and Distribution Conference (Cat. No. 99CH36333).