Single-camera 3D-DIC system based on a fiber bundle

Abstract The three-dimensional digital image correlation (3D-DIC) method featuring two synchronized cameras has been widely used in the field of experimental mechanics to measure full-field 3D shape and deformation. However, the requirement of two synchronized cameras often limits the application of the regular 3D-DIC method. This study proposes a single-camera 3D-DIC system based on a fiber bundle (FB), aiming to make full use of the flexibility of the FB and further broaden the range of application of the 3D-DIC method. The multi-channel FB enables the proposed method to photograph the test object from two different angles with a single camera. In order to verify the effectiveness of the proposed method, a three-point bending deformation measurement experiment and a cylinder 3D reconstruction experiment were carried out. For comparison, the regular 3D-DIC system was used to measure the same specimens. Factors affecting the accuracy of the proposed method were analyzed and the corresponding optimization methods were given. As the proposed method can isolate the imaging sensor from harsh environment, it demonstrates significant potential in determining 3D deformation in intense electromagnetic interference environment and under water.

[1]  J. Joannopoulos,et al.  Wavelength-scalable hollow optical fibres with large photonic bandgaps for CO2 laser transmission , 2002, Nature.

[2]  Anand Asundi,et al.  Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review , 2009 .

[3]  Jianguo Zhu,et al.  Single-lens 3D digital image correlation system based on a bilateral telecentric lens and a bi-prism: validation and application. , 2015, Applied optics.

[4]  Weidong Song,et al.  Full-field transient 3D deformation measurement of 3D braided composite panels during ballistic impact using single-camera high-speed stereo-digital image correlation , 2016 .

[5]  Jean-José Orteu,et al.  3-D computer vision in experimental mechanics , 2007 .

[6]  Hubert W. Schreier,et al.  Image Correlation for Shape, Motion and Deformation Measurements: Basic Concepts,Theory and Applications , 2009 .

[7]  Yong Su,et al.  Full-field wrist pulse signal acquisition and analysis by 3D Digital Image Correlation , 2017 .

[8]  Y. Maoult,et al.  IR Camera based system for high speed granulometry measurement on liquid dispersions , 2020 .

[9]  A. Waas,et al.  Three-dimensional digital image correlation technique using single high-speed camera for measuring large out-of-plane displacements at high framing rates. , 2010, Applied optics.

[10]  Masayuki Inaba,et al.  A stereo viewer based on a single camera with view-control mechanisms , 1993, Proceedings of 1993 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS '93).

[11]  Dongsheng Zhang,et al.  Real-time three-dimensional digital image correlation for biomedical applications , 2016, Journal of biomedical optics.

[12]  Li Yang,et al.  Tunnel contour detection during construction based on digital image correlation , 2020 .

[13]  Shuai Dong,et al.  Self-calibration single-lens 3D video extensometer for high-accuracy and real-time strain measurement. , 2016, Optics express.

[14]  D. Garcia,et al.  A combined temporal tracking and stereo-correlation technique for accurate measurement of 3D displacements: application to sheet metal forming , 2002 .

[15]  Yong Su,et al.  High-Accuracy, High-Efficiency Compensation Method in Two-Dimensional Digital Image Correlation , 2017 .

[16]  M Trivi,et al.  Stereoscopic uses of diffraction gratings. , 1988, Applied optics.

[17]  G. Ravichandran,et al.  Diffraction-Assisted Image Correlation for Three-Dimensional Surface Profiling , 2015 .

[18]  Yanjun Li,et al.  Design and calibration of a single-camera-based stereo vision sensor , 2006 .

[19]  Gang Wang,et al.  Infrared scanning imaging system based on IR fiber bundle , 2010, SPIE/COS Photonics Asia.

[20]  Qingchuan Zhang,et al.  Experimental Study on Three-Dimensional Deformation Field of Portevin–Le Chatelier Effect Using Digital Image Correlation , 2016 .

[21]  N. S. Kapany,et al.  Transparent Fibres for the Transmission of Optical Images , 1955 .

[22]  J. Orteu,et al.  Use of 3-D Digital Image Correlation to Characterize the Mechanical Behavior of a Fiber Reinforced Refractory Castable , 2007 .

[23]  M. A. Sutton,et al.  Accurate measurement of three-dimensional deformations in deformable and rigid bodies using computer vision , 1993 .

[24]  Yong Su,et al.  Accuracy evaluation of optical distortion calibration by digital image correlation , 2017 .

[25]  Kobus Barnard,et al.  Resolution enhancement for fiber bundle imaging using maximum a posteriori estimation. , 2018, Optics letters.

[26]  Xiaoyuan He,et al.  Real-time 3D digital image correlation method and its application in human pulse monitoring. , 2016, Applied optics.

[27]  Qingchuan Zhang,et al.  Creep of stainless steel under heat flux cyclic loading ( 500-1000 ° C ) with different mechanical preloads in a vacuum environment using 3 D-DIC , 2019 .

[28]  Zhang Yong,et al.  High-efficiency and high-accuracy digital image correlation for three-dimensional measurement , 2015 .

[29]  Katia Genovese,et al.  Stereo-Digital Image Correlation (DIC) measurements with a single camera using a biprism , 2013 .

[30]  Stephen A. Boppart,et al.  Depixelation and enhancement of fiber bundle images by bundle rotation. , 2020, Applied optics.

[31]  S. Xia,et al.  Diffraction Assisted Image Correlation: A Novel Method for Measuring Three-Dimensional Deformation using Two-Dimensional Digital Image Correlation , 2013 .

[32]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[33]  A. Ardeshir Goshtasby,et al.  Design of a single-lens stereo camera system , 1993, Pattern Recognit..

[34]  Tao Yu,et al.  Measurement of the 3D Rayleigh index field via time-resolved CH* computed tomography , 2019 .

[35]  I. Yamaguchi,et al.  A laser-speckle strain gauge , 1981 .

[36]  Jianan Zhao,et al.  Numerical and experimental validation of a single-camera 3D velocimetry based on endoscopic tomography. , 2019, Applied optics.

[37]  Qian Zhang,et al.  An Accurate Method for Shape Retrieval and Displacement Measurement Using Bi-Prism-Based Single Lens 3D Digital Image Correlation , 2016 .

[38]  Arnold Daniels,et al.  Fiber optically coupled infrared focal plane array system for use in missile warning receiver applications , 1999, Defense, Security, and Sensing.

[39]  Zhenyu Jiang,et al.  Path-independent digital image correlation with high accuracy, speed and robustness , 2015 .

[40]  Fu Jun Yang,et al.  Digital Speckle Projection for Vibration Measurement by Applying Digital Image Correlation Method , 2006 .

[41]  Michael B. Wallace,et al.  High-Resolution Confocal Endomicroscopy Probe System for In Vivo Diagnosis of Colorectal Neoplasia , 2008 .

[42]  Yue Zhao,et al.  Perspective projection model for prism-based stereovision. , 2015, Optics express.