Direct electrochemistry of glucose oxidase entrapped in nano gold particles-ionic liquid-N,N-dimethylformamide composite film on glassy carbon electrode and glucose sensing.

The direct electrochemistry of glucose oxidase (GOD) entrapped in nano gold particles (NAs)-N,N-dimethylformamide (DMF)-1-butyl-3-methylimidazolium hexafluophosphate (BMIMPF(6)) composite film on a glassy carbon electrode (NAs-DMF-GOD (BMIMPF(6))/GC) has been investigated for first time. The immobilized GOD exhibits a pair of well-defined reversible peaks in 0.050 M pH 5 phosphate solutions (PS), resulting from the redox of flavin adenine dinucleotide (FAD) in GOD. The peak currents are three times as large as those of GOD-NAs-DMF film coated GC electrode (i.e. NAs-DMF-GOD (water)/GC). In addition, the NAs-DMF-GOD (BMIMPF(6)) composite material has higher thermal stability than NAs-DMF-GOD (water). Results show that ionic liquid BMIMPF(6), DMF and NAs are requisite for GOD to exhibit a pair of stable and reversible peaks. Without any of them, the peaks of GOD become small and unstable. Upon the addition of glucose, the peak currents of GOD decrease and a new cathodic peak occurs at -0.8 V (versus SCE), which corresponds to the reduction of hydrogen peroxide (H(2)O(2)) generated by the catalytic oxidation of glucose. The peak current of the new cathodic peak and the glucose concentration show a linear relationship in the ranges of 1.0 x 10(-7) to 1.0 x 10(-6)M and 2.0 x 10(-6) to 2.0 x 10(-5) M. The kinetic parameter I(max) of H(2)O(2) is estimated to be 1.19 x 10(-6)A and the apparent K(m) (Michaelis-Menten constant) for the enzymatic reaction is 3.49 microM. This method has been successfully applied to the determination of glucose in human plasma and beer samples, and the average recoveries are 97.2% and 99%, respectively.

[1]  D. Peters,et al.  Cyclic voltammetric study of the catalytic behavior of nickel(I) salen electrogenerated at a glassy carbon electrode in an ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate, BMIM+BF4−) , 2001 .

[2]  Yinxi Huang,et al.  An electrochemical investigation of glucose oxidase at a CdS nanoparticles modified electrode. , 2005, Biosensors & bioelectronics.

[3]  Martin M. F. Choi,et al.  An optical glucose biosensor based on entrapped-glucose oxidase in silicate xerogel hybridised with hydroxyethyl carboxymethyl cellulose , 2004 .

[4]  Jing-Juan Xu,et al.  Glucose biosensor based on ENFET doped with SiO2 nanoparticles , 2004 .

[5]  M. Goto,et al.  Comb-shaped poly(ethylene glycol)-modified subtilisin Carlsberg is soluble and highly active in ionic liquids. , 2005, Chemical communications.

[6]  M. Matsumoto,et al.  Selective separation of aromatic hydrocarbons through supported liquid membranes based on ionic liquids , 2005 .

[7]  Huangxian Ju,et al.  Application of Colloidal Gold in Protein Immobilization, Electron Transfer, and Biosensing , 2003 .

[8]  S. Dong,et al.  The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix. , 2005, Biosensors & bioelectronics.

[9]  Beatriz López-Ruiz,et al.  High stability amperometric biosensor based on enzyme entrapment in microgels. , 2005, Talanta.

[10]  Liang Ding,et al.  Development of an amperometric biosensor based on glucose oxidase immobilized through silica sol–gel film onto Prussian Blue modified electrode , 2004 .

[11]  Ying Liu,et al.  Electrochemical and bioelectrochemistry properties of room-temperature ionic liquids and carbon composite materials. , 2004, Analytical chemistry.

[12]  Jingchang Zhang,et al.  Activity and stability investigation of [BMIM][AlCl4] ionic liquid as catalyst for alkylation of benzene with 1-dodecene , 2004 .

[13]  J. Retama,et al.  Microstructural modifications induced by the entrapped glucose oxidase in cross-linked polyacrylamide microgels used as glucose sensors. , 2003, Biomaterials.

[14]  Martin M. F. Choi,et al.  Biosensors for determination of glucose with glucose oxidase immobilized on an eggshell membrane. , 2004, Talanta.

[15]  Jing Chen,et al.  Direct electron transfer of glucose oxidase promoted by carbon nanotubes. , 2004, Analytical biochemistry.

[16]  Jinghong Li,et al.  Composite system based on chitosan and room-temperature ionic liquid: direct electrochemistry and electrocatalysis of hemoglobin. , 2006, Biomacromolecules.

[17]  Suxia Zhang,et al.  Immobilization of glucose oxidase on gold nanoparticles modified Au electrode for the construction of biosensor , 2005 .

[18]  G. Rivas,et al.  Glucose biosensors based on the immobilization of glucose oxidase and polytyramine on rodhinized glassy carbon and screen printed electrodes , 2006 .

[19]  Guo-Li Shen,et al.  Amperometric glucose biosensor based on chitosan with improved selectivity and stability , 2004 .

[20]  G. Rivas,et al.  Glucose biosensors based on the immobilization of copper oxide and glucose oxidase within a carbon paste matrix. , 2005, Talanta.

[21]  Huangxian Ju,et al.  Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode. , 2003, Biosensors & bioelectronics.

[22]  X. Chen,et al.  A new step to the mechanism of the enhancement effect of gold nanoparticles on glucose oxidase. , 1998, Biochemical and biophysical research communications.

[23]  S. Yoon,et al.  A novel multi-walled carbon nanotube-based biosensor for glucose detection. , 2003, Biochemical and biophysical research communications.

[24]  Shengshui Hu,et al.  The fabrication of a colloidal gold-carbon nanotubes composite film on a gold electrode and its application for the determination of cytochrome c. , 2005, Colloids and surfaces. B, Biointerfaces.

[25]  C. Ching,et al.  Selective alkylation of phenol with tert-butyl alcohol catalyzed by [bmim]PF6 , 2003 .

[26]  Jinghong Li,et al.  A novel room temperature ionic liquid sol–gel matrix for amperometric biosensor application , 2005 .

[27]  Genxi Li,et al.  Electron transfer reactivity and the catalytic activity of horseradish peroxidase incorporated in dipalmitoylphosphatidic acid films. , 2006, Bioelectrochemistry.

[28]  C. M. Li,et al.  Electrochemical Detection of Nitric Oxide on a SWCNT/RTIL Composite Gel Microelectrode , 2006 .

[29]  Juozas Kulys,et al.  Bioelectrocatalytical glucose oxidation with phenoxazine modified glucose oxidase , 2004 .

[30]  Jinxing Wang,et al.  Multilayered construction of glucose oxidase and gold nanoparticles on Au electrodes based on layer-by-layer covalent attachment , 2006 .

[31]  M. Vaher,et al.  Application of 1-alkyl-3-methylimidazolium-based ionic liquids in non-aqueous capillary electrophoresis. , 2002, Journal of chromatography. A.