Performance Test of Energy Dissipation Bearing and Its Application in Seismic Control of a Long-Span Bridge

Energy dissipation bearing (EDB) is a conventional steel bridge bearing in connection with well designed mild steel dampers. Seismic performance test was undertaken for both damper units and a prototype bearing, and the results show very stable and high dissipation characteristics. In describing the hysteretic behavior of EDBs, the Wen model is proved to be more reasonable, and the corresponding model parameters are also proposed according to the test results. EDBs have been applied in the seismic control of a long span bridge, the Nanjing Jia River Bridge, for the first time, in both the longitudinal and transverse directions. Sensitivity studies were conducted to investigate the effectiveness and to determine the optimum parameters and distribution of the EDBs through nonlinear time-history analysis. The results show that EDBs achieve a very high effectiveness in seismic control, in both the longitudinal and transverse directions. Compared with other damping devices, they can provide a simple but valid seismic control solution, with low maintenance requirements, especially in the transverse direction.

[1]  Yoshiaki Okui,et al.  Hyperelasticity Model for Finite Element Analysis of Natural and High Damping Rubbers in Compression and Shear , 2006 .

[2]  R. Boroschek,et al.  Dynamic characteristics of a long span seismic isolated bridge , 2003 .

[3]  Michael C. Constantinou,et al.  Experimental Study of Friction‐Pendulum Isolation System , 1991 .

[4]  Jorge Daniel Riera,et al.  Reliability based assessment of the effectiveness of metallic dampers in buildings under seismic excitations , 2004 .

[5]  Y. Itoh,et al.  Prediction of Aging Characteristics in Natural Rubber Bearings Used in Bridges , 2009 .

[6]  Andrew S. Whittaker,et al.  Seismic Testing of Steel Plate Energy Dissipation Devices , 1991 .

[7]  S. Infanti RION-ANTIRION BRIDGE: DESIGN AND FULL-SCALE TESTING OF THE SEISMIC PROTECTION DEVICES , 2004 .

[8]  Andrew S. Whittaker,et al.  Experimental Study of the XY-Friction Pendulum Bearing for Bridge Applications , 2009 .

[9]  Y. Wen Method for Random Vibration of Hysteretic Systems , 1976 .

[10]  Stephen A. Mahin,et al.  A Simple Pendulum Technique for Achieving Seismic Isolation , 1990 .

[11]  Fan Li-chu,et al.  Lateral Constraint Systems for Super-long-span Cable-stayed Bridge , 2007 .

[12]  Joan R. Casas,et al.  A direct displacement-based method for the seismic design of bridges on bi-linear isolation devices , 2006 .

[13]  P. TSOPELAS,et al.  Experimental study of FPS system in bridge seismic isolation , 1996 .

[14]  M. Feng,et al.  China's Major Bridges , 2009 .

[15]  R. S. Jangid Stochastic Response of Bridges Seismically Isolated by Friction Pendulum System , 2008 .

[16]  C. S. Tsai,et al.  FINITE ELEMENT FORMULATIONS FOR FRICTION PENDULUM SEISMIC ISOLATION BEARINGS , 1997 .

[17]  R. S. Jangid,et al.  Seismic behavior of isolated bridges: A-state-of-the-art review , 2003 .

[18]  D. K. Paul,et al.  Force-Deformation Behavior of Isolation Bearings , 2007 .

[19]  Chen Dan-hua Discuss on《Code for Design of Ground Base and Foundation of Highway Bridges and Culverts》 , 2011 .

[20]  Hani Nassif,et al.  Evaluation of Laminated Circular Elastomeric Bearings , 2007 .