A review of the emission of VOCs from polymeric materials used in buildings

Abstract Building and furnishing materials and consumers products are important sources of formaldehyde and other volatile organic compounds (VOCs) in the indoor environment. The emission from materials is usually continuous and may last for many years in a building. The available evidence indicates that VOCs can cause adverse health effects to the building occupants and may contribute to symptoms of ‘Sick Building Syndrome’. Control of VOC emission should increasingly become an important consideration for the design and manufacture of polymeric materials used in buildings. The EC Construction Products Directive ‘Essential Requirements’ set a framework for limiting the use of materials that could pose a health risk to building occupants. Furthermore, the on-going development of voluntary labelling schemes and data bases of material emissions that could be used by building designers, should further strengthen the demand for ‘low VOC emitting’ products. This paper reviews available information about the emission of VOCs from polymeric building materials, the level of emissions in the indoor environment and the requirements for testing of the materials.

[1]  Lars Mølhave,et al.  Indoor air pollution due to organic gases and vapours of solvents in building materials , 1982 .

[2]  Fx Young Practical Applications of Gas Chromatography in the Paint and Coatings Industry , 1992 .

[3]  O. Seppänen,et al.  Classification of Indoor Climate, Construction, and Finishing Materials , 1997 .

[4]  T. G. Matthews,et al.  Environmental chamber test methodology for characterizing organic vapors from solid emission sources , 1987 .

[5]  Per Axel Clausen,et al.  The Danish Twin Apartment Study; Part I: Formaldehyde and Long‐Term VOC Measurements , 1991 .

[6]  Hal Levin,et al.  Controlling Sources of Indoor Air Pollution , 1992 .

[7]  Wolfgang Bischof,et al.  European data base on indoor air pollution sources in buildings: current status of data base structure and software , 1996 .

[8]  L. Mølhave,et al.  Volatile Organic Compounds, Indoor Air Quality and Health , 1991 .

[9]  Derrick Crump,et al.  Sources and Concentrations of Formaldehyde and Other Volatile Organic Compounds in the Indoor Air of Four Newly Built Unoccupied Test Houses , 1997 .

[10]  L. E. Sparks,et al.  Source testing and data analysis for exposure and risk assessment of indoor pollutant sources. Report for September 1993-June 1994 , 1995 .

[11]  Per Axel Clausen,et al.  The Danish Twin Apartment Study – Part II: Mathematical modeling of the relative strength of sources of indoor air pollution , 1996 .

[12]  Hans Gustafsson,et al.  Building materials identified as major sources for indoor air pollutants : a critical review of case studies , 1992 .

[13]  L. E. Sparks,et al.  Fundamental mass transfer models for indoor air pollution sources , 1993 .

[14]  Lance Wallace,et al.  Emissions of volatile organic compounds from building materials and consumer products , 1987 .

[15]  Jari Nobrega Cardosa Health Buildings '94: Budapest, Hungary, August 22-25, 1994 , 1994 .

[16]  D. Gardiner,et al.  Measurement of volatile organic compounds in indoor air by a passive technique , 1992 .

[17]  D. Gardiner,et al.  Long term diffusive sampling of volatile organic compounds in indoor air , 1993 .

[18]  Fariborz Haghighat,et al.  Emissions of Indoor Pollutants from Building Materials—State of the Art Review , 1993 .

[19]  B. Seifert,et al.  Regulating Indoor Air , 1992 .

[20]  D. Gardiner,et al.  Determination of aromatic hydrocarbon emissions from paint and related products by an impinger method , 1990 .

[21]  V. M. Brown,et al.  Appropriate Sampling Strategies for the Measurement of Formaldehyde in Indoor Air , 1995 .

[22]  Peder Wolkoff,et al.  Health-related evaluation of building products based on climate chamber tests , 1994 .