Continuous Intracranial Pressure Monitoring and Serial Electroencephalographic Recordings in Severely Asphyxiated Term Neonates

• We report our observations from Intensive intracranial pressure (ICP) monitoring and serial clinical neurologic and electroencephalographic examinations in ten asphyxiated full-term neonates, of whom five died and at least two survivors had multiple severe neurologic handicaps. Direct measurements of ICP were obtained by a newly developed infant subarachnoid bolt and/or a transfontanelle pressure transducer. Simultaneous ICPs were recorded and correlated when possible. We noted a dependence of transfontanelle ICP values on application technique and force. In infants with no bleeding diathesis, the subarachnoid bolt was safe and no complications were encountered. Only six infants experienced pathologic elevations of ICP following birth asphyxia, and of these infants only two had sustained, marked Increases of ICP. We also noted abundant fluctuations of cerebral perfusion pressure (mean arterial blood pressure minus ICP), but the majority of fluctuations were accounted for by mean arterial pressure changes rather than ICP changes. We found no deterioration of clinical neurologic function as measured by serial mental status examinations and electroencephalogram samples at the time the maximum ICP was measured. We also noted very little change in ICP during most electrographic seizures. In these infants ICP did increase after birth but major ICP elevations were uncommon and did not appear to introduce any acute functional neurologic disturbances. Most changes in cerebral perfusion pressure were attributed to blood pressure rather than ICP changes. It appears unlikely that cerebral edema and elevated ICP play a major role in determining neurologic outcome in some asphyxiated term infants. (AJDC1988;142:740-747)

[1]  D. Evans,et al.  VALUE OF INTRACRANIAL PRESSURE MONITORING OF ASPHYXIATED NEWBORN INFANTS , 1987, Developmental medicine and child neurology.

[2]  A. Kaiser,et al.  NON‐INVASIVE MONITORING OF INTRACRANIAL PRESSURE‐FACT OR FANCY? , 1987, Developmental medicine and child neurology.

[3]  A. Brann Hypoxic ischemic encephalopathy (asphyxia). , 1986, Pediatric clinics of North America.

[4]  A. Hill,et al.  Intracranial pressure measurements in the newborn. , 1985, Clinics in perinatology.

[5]  D. Evans,et al.  Medical management of raised intracranial pressure after severe birth asphyxia. , 1985, Archives of disease in childhood.

[6]  B. Tharp,et al.  EEG in premature infants with intraventricular hemorrhage , 1984, Neurology.

[7]  D. Evans,et al.  Continuous measurement of subarachnoid pressure in the severely asphyxiated newborn. , 1983, Archives of disease in childhood.

[8]  L. Ivan,et al.  Clinical and experimental observations with fontanel pressure measurements. , 1983, Child's brain.

[9]  D. Easa,et al.  Noninvasive intracranial pressure measurement in the newborn. , 1983, American journal of diseases of children.

[10]  P. Walsh,et al.  Continuous and intermittent measurement of intracranial pressure by Ladd monitor. , 1983, The Journal of pediatrics.

[11]  Y. Amit,et al.  Intracranial pressure in central nervous system infections and cerebral ischaemia of infancy. , 1983, Archives of disease in childhood.

[12]  H. Bada Intracranial monitoring. Its role and application in neonatal intensive care. , 1983, Clinics in perinatology.

[13]  J. Volpe,et al.  Seizures in the preterm infant: effects on cerebral blood flow velocity, intracranial pressure, and arterial blood pressure. , 1983, The Journal of pediatrics.

[14]  N. Finer,et al.  Factors affecting outcome in hypoxic-ischemic encephalopathy in term infants. , 1983, American journal of diseases of children.

[15]  T. Raju,et al.  Cerebral perfusion pressure studies in healthy preterm and term newborn infants. , 1982, The Journal of pediatrics.

[16]  J H Ellenberg,et al.  Apgar scores as predictors of chronic neurologic disability. , 1981, Pediatrics.

[17]  T. Raju,et al.  Cerebral perfusion pressure and abnormal intracranial pressure wave forms: their relation to outcome in birth asphyxia , 1981, Critical care medicine.

[18]  J. Volpe,et al.  Measurement of intracranial pressure using the Ladd intracranial pressure monitor. , 1981, The Journal of pediatrics.

[19]  T. Raju,et al.  Intracranial pressure monitoring in the neonatal ICU , 1980, Critical care medicine.

[20]  M. C. Rogers,et al.  Control of cerebral circulation in the neonate and infant , 1980, Critical care medicine.

[21]  J. Horbar,et al.  Effect of application force on noninvasive measurements of intracranial pressure. , 1980, Pediatrics.

[22]  B. Shaywitz,et al.  Monitoring and management of increased intracranial pressure in Reye syndrome: results in 29 children. , 1980, Pediatrics.

[23]  A. Allen,et al.  Neonatal asphyxia. II. Neonatal mortality and long-term sequelae. , 1980, The Journal of pediatrics.

[24]  F. Plum,et al.  Ischemic brain edema requires tissue necrosis. , 1980, Transactions of the American Neurological Association.

[25]  H. Lou,et al.  Low cerebral blood flow: a risk factor in the neonate. , 1979, The Journal of pediatrics.

[26]  A. Conn.,et al.  Cerebral resuscitation in near-drowning. , 1979, Pediatric clinics of North America.

[27]  A. Philip Noninvasive monitoring of intracranial pressure: a new approach for neonatal clinical pharmacology. , 1979, Clinics in perinatology.

[28]  N. Lassen,et al.  Impaired autoregulation of cerebral blood flow in the distressed newborn infant. , 1979, The Journal of pediatrics.

[29]  M. L. Marsh,et al.  Neurosurgical Intensive Care , 1977, Anesthesiology.

[30]  T. Raju,et al.  A simple noninvasive technique of measuring intracranial pressure in the newborn. , 1977, Pediatrics.

[31]  H. Scott,et al.  Outcome of very severe birth asphyxia. , 1976, Archives of disease in childhood.

[32]  D. Becker,et al.  A subarachnoid screw for monitoring intracranial pressure. Technical note. , 1973, Journal of neurosurgery.