In vitro integrity of implant external hexagon after application of surgical placement torque simulating implant locking.

The aim of this study was to evaluate the integrity of the external hexagon of an implant system with internal and external hexagons but with prosthetic connection through the external hexagon (Internal Torque, IT) in comparison with that of an implant system with external hexagon with mount (External Hexagon, EH). A device was made to measure the rotational freedom angles between implant and abutment hexagons in 10 implants from each group after the application of surgical placement torques of 45, 60 and 80 Ncm simulating implant locking. The distances between the vertices of the external hexagon were also obtained. Rotational freedom data were subjected to ANOVA and Tukey's test (P < .05) showing no significant difference between the angles of the intact implants (EH - 3.31 +/- 0.41 degrees and IT - 3.30 +/- 0.17 degrees ) and after application of a 45 Ncm torque (EH - 3.27 +/- 0.38 degrees and IT - 3.31 +/- 0.22 degrees ). However, after application of a 60 Ncm torque there were significant differences (IT - 3.40 +/- 0.20 degrees and EH - 4.03 +/- 0.54 degrees ). After application of a 80 Ncm torque, the IT implant presented values of 3.39 +/- 0.21 degrees whereas the EH did not support the torque, suffering deformation of its external hexagon. Within the limits of this study, it can be concluded that the IT implant system may be preferable in clinical situations where implant placement within a certain bone density could generate torques higher than 60 Ncm.

[1]  Hom-lay Wang,et al.  Consensus Conference on Immediate Loading: The Single Tooth and Partial Edentulous Areas , 2006, Implant dentistry.

[2]  N. Lang,et al.  Significance of primary stability for osseointegration of dental implants. , 2006, Clinical oral implants research.

[3]  Marco Degidi,et al.  Comparative analysis study of 702 dental implants subjected to immediate functional loading and immediate nonfunctional loading to traditional healing periods with a follow-up of up to 24 months. , 2005, The International journal of oral & maxillofacial implants.

[4]  C. Misch Immediate loading of definitive implants in the edentulous mandible using a fixed provisional prosthesis: The denture conversion technique. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[5]  da Cunha Ha,et al.  A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. , 2004 .

[6]  Niklaus P Lang,et al.  Critical review of immediate implant loading. , 2003, Clinical oral implants research.

[7]  P Vigolo,et al.  Measurement of the dimensions and abutment rotational freedom of gold-machined 3i UCLA-type abutments in the as-received condition, after casting with a noble metal alloy and porcelain firing. , 2000, The Journal of prosthetic dentistry.

[8]  O Bahat,et al.  Brånemark system implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years. , 2000, The International journal of oral & maxillofacial implants.

[9]  U. Belser,et al.  Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. , 2000, The International journal of oral & maxillofacial implants.

[10]  J I Nicholls,et al.  Tolerance measurements of various implant components. , 1997, The International journal of oral & maxillofacial implants.

[11]  P P Binon,et al.  The effect of eliminating implant/abutment rotational misfit on screw joint stability. , 1996, The International journal of prosthodontics.

[12]  P P Binon,et al.  The effect of implant/abutment hexagonal misfit on screw joint stability. , 1996, The International journal of prosthodontics.

[13]  G Watzek,et al.  Brånemark single tooth implants: a preliminary report of 76 implants. , 1995, The Journal of prosthetic dentistry.

[14]  P P Binon,et al.  Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs. , 1995, The International journal of prosthodontics.

[15]  R A Wicks,et al.  An evaluation of fit in osseointegrated implant components using torque/turn analysis. , 1994, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[16]  J K Schulte,et al.  EXTERNAL HEX MANUFACTURING TOLERANCES OF SIX IMPLANT SYSTEMS: A PILOT STUDY , 1994, Implant dentistry.

[17]  P. Vigolo,et al.  An in vitro evaluation of ZiReal abutments with hexagonal connection: in original state and following abutment preparation. , 2005, The International journal of oral & maxillofacial implants.

[18]  Hugo Nary Filho,et al.  A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. , 2004, The International journal of oral & maxillofacial implants.

[19]  Lisa A Lang,et al.  The influence of abutment screw tightening on screw joint configuration. , 2002, The Journal of prosthetic dentistry.

[20]  P Johansson,et al.  Assessment of bone quality from cutting resistance duringimplant surgery , 1994 .

[21]  T. Waris,et al.  Cold injury of the rat skin. A fluorescence histochemical study of adrenergic nerves, mast cells and patency of cutaneous blood vessels. , 1982, Scandinavian journal of plastic and reconstructive surgery.

[22]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[23]  P. Branemark,et al.  Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. , 1977, Scandinavian journal of plastic and reconstructive surgery. Supplementum.