Gait Rehabilitation therapy using robot generated force fields applied at the pelvis

The Robotic Gait Rehabilitation (RGR) Trainer was designed and built to target secondary gait deviations in patients post - stroke. While patients ambulate on a treadmill, force fields are applied to the pelvis, which generate corrective forces as a response to deviations from normal pelvic motion. The device is coupled to the patient via an orthopedic brace, and a linear electromagnetic actuator provides power. Healthy human subject testing confirmed efficacy of the method to impart significant gait restoration forces as a response to abnormal pelvic obliquity (hip hiking). This novel approach to application of force fields using endpoint impedance controlled linear actuators takes into account patients' soft tissue dynamics.

[1]  A. LaCroix,et al.  Maintaining mobility in late life. I. Demographic characteristics and chronic conditions. , 1993, American journal of epidemiology.

[2]  S.J. Harkema,et al.  A Robot and Control Algorithm That Can Synchronously Assist in Naturalistic Motion During Body-Weight-Supported Gait Training Following Neurologic Injury , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[3]  Peter H. Veltink,et al.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers , 2005, Medical and Biological Engineering and Computing.

[4]  H C Chiu,et al.  Physical functioning and health-related quality of life: before and after total hip replacement. , 2000, The Kaohsiung journal of medical sciences.

[5]  R. Riener,et al.  Patient-cooperative strategies for robot-aided treadmill training: first experimental results , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[6]  Ack,et al.  LOWER-EXTREMITY FUNCTION IN PERSONS OVER THE AGE OF 70 YEARS AS A PREDICTOR OF SUBSEQUENT DISABILITY , 2001 .

[7]  N. Hogan,et al.  Robot-aided neurorehabilitation. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[8]  J R Jenner,et al.  Changing patterns of postural hip muscle activity during recovery from stroke , 2000, Clinical rehabilitation.

[9]  T Limbird,et al.  Electromyographic gait assessment, Part 2: Preliminary assessment of hemiparetic synergy patterns. , 1987, Journal of rehabilitation research and development.

[10]  A. B. Drought,et al.  WALKING PATTERNS OF NORMAL MEN. , 1964, The Journal of bone and joint surgery. American volume.

[11]  Stephen Paul Buerger,et al.  Stable, high-force, low-impedance robotic actuators for human-interactive machines , 2005 .

[12]  Neville Hogan,et al.  Stable execution of contact tasks using impedance control , 1987, Proceedings. 1987 IEEE International Conference on Robotics and Automation.

[13]  H. van der Kooij,et al.  Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.