TOPOS: a new topometric patient positioning and tracking system for radiation therapy based on structured white light.

PURPOSE A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. METHODS Two optical sensors are the main parts of the TOPOS® system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 × 488 pixels). The projector has a resolution of 1024 × 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. RESULTS Two prototypes have been developed, each allowing a continuous high density scan of a 500 × 500 × 400 mm(3) (L × W × D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 ± 0.4, -0.2 ± 0.7, and -0.1 ± 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 ± 0.5, -0.6 ± 1.9, 0.0 ± 0.4 mm. CONCLUSIONS The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

[1]  George T. Y. Chen,et al.  A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup. , 2005, Medical physics.

[2]  A. Brahme,et al.  4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures. , 2008, Medical physics.

[3]  Søren M Bentzen,et al.  Radiation therapy: intensity modulated, image guided, biologically optimized and evidence based. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  Andrew W. Fitzgibbon Robust registration of 2D and 3D point sets , 2003, Image Vis. Comput..

[5]  Hiroki Shirato,et al.  Adaptive prediction of respiratory motion for motion compensation radiotherapy , 2007, Physics in medicine and biology.

[6]  P Aaltonen,et al.  Specification of dose delivery in radiation therapy. Recommendation by the Nordic Association of Clinical Physics (NACP). , 1997, Acta oncologica.

[7]  Francis Lilley,et al.  Opto-electronic sensing of body surface topology changes during radiotherapy for rectal cancer. , 2003, International journal of radiation oncology, biology, physics.

[8]  Marc Levoy,et al.  Efficient variants of the ICP algorithm , 2001, Proceedings Third International Conference on 3-D Digital Imaging and Modeling.

[9]  Jan Hrbacek,et al.  Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm. , 2011, International journal of radiation oncology, biology, physics.

[10]  D.-J. Guan,et al.  GENERALIZED GRAY CODES WITH APPLICATIONS , 1998 .

[11]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[12]  Baba C. Vemuri,et al.  A robust algorithm for point set registration using mixture of Gaussians , 2005, Tenth IEEE International Conference on Computer Vision (ICCV'05) Volume 1.

[13]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[14]  Joachim Hornegger,et al.  Time-of-Flight sensor for patient positioning , 2009, Medical Imaging.

[15]  George T. Y. Chen,et al.  A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup. , 2005, Medical physics.

[16]  Nils Achterberg,et al.  Multibeam tomotherapy: a new treatment unit devised for multileaf collimation, intensity-modulated radiation therapy. , 2007, Medical physics.

[17]  Darren Kahler,et al.  Characterization of a real-time surface image-guided stereotactic positioning system. , 2010, Medical physics.

[18]  Christoph Bert,et al.  Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients. , 2006, International journal of radiation oncology, biology, physics.

[19]  A Gustavsson,et al.  The long-term consequences of therapy for Hodgkin's disease are still evolving. , 1997, Acta oncologica.

[20]  H. L. Mitchell,et al.  Medical photogrammetric measurement: overview and prospects , 2002 .

[21]  S. Kloeck,et al.  An exact and objective positioning system for patients in conformal radiotherapy basing on optical 3D-surface-detection , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[22]  Kostas Daniilidis,et al.  Fully Automatic Registration of 3D Point Clouds , 2006, 2006 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'06).

[23]  S. J. Marshall,et al.  Human body 3D imaging by speckle texture projection photogrammetry , 2000 .

[24]  Elli Angelopoulou,et al.  Fast time-of-flight camera based surface registration for radiotherapy patient positioning. , 2011, Medical physics.

[25]  T R Mackie,et al.  History of tomotherapy , 2006, Physics in medicine and biology.

[26]  David I Thwaites,et al.  Back to the future: the history and development of the clinical linear accelerator , 2006, Physics in medicine and biology.

[27]  Paul J. Besl,et al.  A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[28]  V. Srinivasan,et al.  Automated phase-measuring profilometry of 3-D diffuse objects. , 1984, Applied optics.