Strongly robust approach for temperature monitoring of power cable joint
暂无分享,去创建一个
Chao Liu | Jiangjun Ruan | Liezheng Tang | Zhibin Qiu | Liezheng Tang | J. Ruan | K. Tang | Zhibin Qiu | Chao Liu | Ke Tang
[1] Lin Yang,et al. Comparison of Conductor-Temperature Calculations Based on Different Radial-Position-Temperature Detections for High-Voltage Power Cable , 2018 .
[2] M. J. Thelwell,et al. Transient thermal performance of e.h.v.-cable joints , 1972 .
[3] B. M. Weedy. Prediction of steady state temperatures in a three-core distribution cable and splice , 1986 .
[4] R. Venkata Rao,et al. Thermal performance optimization of the underground power cable system by using a modified Jaya algorithm , 2018 .
[5] K. Kawasaki,et al. Conductor temperature monitoring system in underground power transmission XLPE cable joints , 1992 .
[6] Li Zhang,et al. A Thermal Probability Density–Based Method to Detect the Internal Defects of Power Cable Joints , 2018, Energies.
[7] Gang Liu,et al. Investigation of the Ampacity of a Prefabricated Straight-Through Joint of High Voltage Cable , 2017 .
[8] H. Riege,et al. A New Method for Cable Joints Thermal Analysis , 1980, IEEE Transactions on Power Apparatus and Systems.
[9] Ge Zhendong. Experimental Study on Cable Joint Temperature Measurement Technology Under Step Current , 2013 .
[10] J. Lis,et al. Analogue investigation of water cooling of e.h.v. cables , 1965 .
[11] B. M. Weedy,et al. Steady-state thermal analysis of a 400 kV-cable through joint , 1967 .
[12] Seyyed Mehdi Mirimani,et al. Electromagnetic and thermal analysis of underground power solid‐conductor cables under harmonic and unbalancing currents based on FEM , 2018 .
[13] Alberto Geri,et al. Underground MV power cable joints: A nonlinear thermal circuit model and its experimental validation , 2017 .
[14] Olivier Moreau,et al. Mock-Up Study of the Effect of Wall Distance on the Thermal Rating of Power Cables in Ventilated Tunnels , 2017, IEEE Transactions on Power Delivery.
[15] James A. Pilgrim,et al. Review of the Accuracy of Single Core Equivalent Thermal Model for Offshore Wind Farm Cables , 2018, IEEE Transactions on Power Delivery.
[16] Liu Chao,et al. Hot Spot Temperature of Cable Joint Considering Contact Resistance , 2016 .
[17] Chao Liu,et al. Hot spot temperature inversion for the single-core power cable joint , 2016 .
[18] Yunpeng Gao,et al. Research on temperature retrieval and fault diagnosis of the cable joint , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.
[19] S. T. Larsen,et al. Assessment of the Impact of Joint Bays on the Ampacity of High-Voltage Cable Circuits , 2009, IEEE Transactions on Power Delivery.
[20] Dardan Klimenta,et al. Controlling the thermal environment of underground cable lines using the pavement surface radiation properties , 2018 .
[21] Ashok Kr Naskar,et al. Transient thermal analysis of underground power cables using two dimensional finite element method , 2018 .