CFD investigation of effect of relative roughness height on Nusselt number and friction factor in an artificially roughened solar air heater

Solar air heaters are cheap and extensively used solar energy collection devices for space heating, seasoning of timber, curing of industrial products and can also be effectively used for curing/drying of concrete/clay building components and in air-conditioning systems. In this article, the effect of relative roughness height on Nusselt number and friction factor in an artificially roughened solar air heater having circular-sectioned transverse rib roughness (duct aspect ratio, AR  =  5:1) is studied by adopting CFD (computational fluid dynamics) approach. Numerical solutions are obtained using commercial CFD software ANSYS FLUENT v12.1. Computations based on the finite volume method with the SIMPLE algorithm have been conducted. Circular-sectioned transverse ribs are applied at the underside of the top of the duct, that is, on the absorber plate. The rib pitch (P) and rib height (e) are varied by keeping rib-pitch-to-rib-height ratio constant (P/e = 14.29). The rib-height-to-hydraulic-diameter ratio (e/D) studied is 0.021, 0.03, 0.042, and 0.06. For each rib-height-to-hydraulic-diameter ratio (e/D), simulations are executed at six Reynolds numbers from 3800 to 18,000 (relevant in solar air heater). The thermal enhancement factor for e/D = 0.042 is found to be the best for the investigated range of parameters and is about 1.635.

[1]  B. N. Prasad,et al.  Investigation for the optimal thermohydraulic performance of artificially roughened solar air heaters , 2000 .

[2]  M. Mcpherson,et al.  Introduction to fluid mechanics , 1997 .

[3]  William A. Beckman,et al.  Solar Engineering of Thermal Processes, 2nd ed. , 1994 .

[4]  B. N. Prasad,et al.  Effect of artificial roughness on heat transfer and friction factor in a solar air heater , 1988 .

[5]  E. Eckert,et al.  Application of rough surfaces to heat exchanger design , 1972 .

[6]  Angelika Bayer,et al.  Solar Engineering Of Thermal Processes , 2016 .

[7]  S. Mullick,et al.  Heat transfer characteristics of a solar air heater used for drying purposes , 1983 .

[8]  Ranjit Singh,et al.  A review on methodology of artificial roughness used in duct of solar air heaters , 2010 .

[9]  R. Saini,et al.  CFD based performance analysis of a solar air heater duct provided with artificial roughness , 2009 .

[10]  S. C. Solanki,et al.  Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate , 2002 .

[11]  R. P. Saini,et al.  Performance of artificially roughened solar air heaters—A review , 2009 .

[12]  A. D. Young,et al.  An Introduction to Fluid Mechanics , 1968 .

[13]  S. C. Solanki,et al.  Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater , 2006 .

[14]  A. N. Tikekar,et al.  Analysis of fluid flow and heat transfer in a rib grit roughened surface solar air heater using CFD , 2010 .

[15]  Anil Kumar,et al.  Heat and fluid flow characteristics of roughened solar air heater ducts – A review , 2012 .

[16]  B. N. Prasad Thermal performance of artificially roughened solar air heaters , 2013 .

[17]  R. Saini,et al.  Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having arc-shaped wire as artificial roughness , 2008 .

[18]  J. L. Bhagoria,et al.  Heat transfer and fluid flow analysis of solar air heater: A review of CFD approach , 2013 .

[19]  H. Gurney Heat Transmission , 1909, Nature.

[20]  R. Saini,et al.  Experimental investigation on heat transfer and fluid flow characteristics of air flow in a rectangular duct with Multi v-shaped rib with gap roughness on the heated plate , 2012 .

[21]  B. Launder,et al.  Lectures in mathematical models of turbulence , 1972 .