Jointless structure and under-actuation mechanism for compact hand exoskeleton

It is important for a wearable robot to be compact and sufficiently light for use as an assistive device. Since human fingers are arranged in a row in dense space, the concept of traditional wearable robots using a rigid frame and a pin joint result in size and complexity problems. A structure without a conventional pin joint, called a jointless structure, has the potential to be used as a wearable robotic hand because the human skeleton and joint can replace the robot's conventional structure. Another way to reduce the weight of the system is to use under-actuation. Under-actuation enables adaptive grasping with less number of actuators for robotic hands. Differential mechanisms are widely used for multi-finger under-actuation; however, they require additional working space. We propose a design with a jointless structure and a novel under-actuation mechanism to reduce the size and weight of a hand exoskeleton. Using these concepts, we developed a prototype that weighs only 80 grams. To evaluate the prototype, fingertip force and blocked force are measured. Fingertip force is the force that can be applied by the finger of the hand exoskeleton on the object surface. The fingertip force is about 18 N when actuated by a tension force of 35 N from the motor. 18 N is sufficient for simple pinch motion in daily activities. Another factor related to performance of the under-actuation mechanism is blocked force, which is a force required to stop one finger while the other finger keeps on moving. It is measured to be 0.5 N, which is sufficiently small. With these experiments, the feasibility of the new hand exoskeleton has been shown.

[1]  Francesco Giovacchini,et al.  HANDEXOS: Towards an exoskeleton device for the rehabilitation of the hand , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[2]  Kenneth R. Diller,et al.  Annual review of biomedical engineering , 1999 .

[3]  R. Riener,et al.  ARMin - Exoskeleton for Arm Therapy in Stroke Patients , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[4]  Takashi Maeno,et al.  Underactuated five-finger prosthetic hand inspired by grasping force distribution of humans , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[5]  Niels Smaby,et al.  Identification of key pinch forces required to complete functional tasks. , 2004, Journal of rehabilitation research and development.

[6]  Paolo Dario,et al.  Design and development of an underactuated prosthetic hand , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[7]  Jerry E. Pratt,et al.  The RoboKnee: an exoskeleton for enhancing strength and endurance during walking , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[8]  Ju Wang,et al.  Design of an exoskeleton for index finger rehabilitation , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  E. Rocon,et al.  Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[10]  A.M. Dollar,et al.  The SDM Hand as a Prosthetic Terminal Device: A Feasibility Study , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[11]  Catherine Ann Kernich,et al.  Post Stroke Rehabilitation, Clinical Practice Guideline, Number 16 , 1996 .

[12]  Yoky Matsuoka,et al.  Comparison of control strategies for an EMG controlled orthotic exoskeleton for the hand , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[13]  Kelly P Westlake,et al.  Pilot study of Lokomat versus manual-assisted treadmill training for locomotor recovery post-stroke , 2009, Journal of NeuroEngineering and Rehabilitation.

[14]  Steven C Cramer,et al.  Robotics, motor learning, and neurologic recovery. , 2004, Annual review of biomedical engineering.

[15]  Sarah J. Housman,et al.  A Randomized Controlled Trial of Gravity-Supported, Computer-Enhanced Arm Exercise for Individuals With Severe Hemiparesis , 2009, Neurorehabilitation and neural repair.

[16]  D G Kamper,et al.  Quantitative features of the stretch response of extrinsic finger muscles in hemiparetic stroke , 2000, Muscle & nerve.

[17]  R. L. Linscheid,et al.  Forces in the normal and abnormal hand , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[18]  L. Der-Yeghiaian,et al.  Robot-based hand motor therapy after stroke. , 2007, Brain : a journal of neurology.

[19]  T. Kline,et al.  Control system for pneumatically controlled glove to assist in grasp activities , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[20]  Andreas Wege,et al.  Development and control of a hand exoskeleton for rehabilitation of hand injuries , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[21]  Yasuhisa Hasegawa,et al.  Wearable handling support system for paralyzed patient , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[22]  Paolo Dario,et al.  The SPRING Hand: Development of a Self-Adaptive Prosthesis for Restoring Natural Grasping , 2004, Auton. Robots.