The comparison of two different intraarticular injections using a sonographic anterolateral approach in patients with osteoarthritic knee

Background The intraarticular (IA) injection has become popular for the management of the osteoarthritic knee without an effusion. The success rate of IA injection would be better if it was able to be visually confirmed. We hypothesized that an anterolateral approach, which targets the synovial membrane of the lateral condyle using ultrasound, would provide an equivalent alternative to the anterolateral approach, targeting the synovial membrane of the medial condyle for IA injection of the knee. Methods A total of 96 knees with osteoarthritis were randomized placed into the two groups, which were group I (anterolateral approach to the medial condyle) and group II (anterolateral approach to the lateral condyle). The primary outcome was to compare the success rate of the two methods of IA injection. The required length of the needle for injection was also measured and compared. Pain intensity was assessed using the Numeric Rating Scale in order to evaluate the success of injection. Results There were no significant differences in the success rate between both groups. The success rate of group I and group II were 87.8% (95%, CI 78.7–97.0) and 91.5% (95%, CI 83.6–99.5), respectively (P = 0.549). The needle depth was 5.0 ± 0.8 (3.0 to 6.1 cm) in group I, and 3.0 ± 0.8 (1.5 to 5 cm) in group II (P < 0.001). Conclusions The anterolateral approach to the lateral femoral condyle, using ultrasound, is an alternative method to the approach targeting the medial femoral condyle, using shorter needle.

[1]  A. Bankhurst,et al.  The highly accurate anteriolateral portal for injecting the knee , 2011, Sports medicine, arthroscopy, rehabilitation, therapy & technology : SMARTT.

[2]  J. Isaacs,et al.  A randomized, double-blind, controlled study of ultrasound-guided corticosteroid injection into the joint of patients with inflammatory arthritis. , 2010, Arthritis and rheumatism.

[3]  A. Bankhurst,et al.  Does Sonographic Needle Guidance Affect the Clinical Outcome of Intraarticular Injections? , 2009, The Journal of Rheumatology.

[4]  M. Esenyel,et al.  Comparison of four different intra-articular injection sites in the knee: a cadaver study , 2007, Knee Surgery, Sports Traumatology, Arthroscopy.

[5]  A. Bodenham,et al.  Visualisation of needle position using ultrasonography , 2006, Anaesthesia.

[6]  H. Schumacher,et al.  Injectable corticosteroids in treatment of arthritis of the knee. , 2005, The American journal of medicine.

[7]  S. Shott,et al.  Corticosteroid Compared with Hyaluronic Acid Injections for the Treatment of Osteoarthritis of the Knee: A Prospective, Randomized Trial , 2003, The Journal of bone and joint surgery. American volume.

[8]  D. W. Jackson,et al.  Accuracy of Needle Placement into the Intra-Articular Space of the Knee , 2002, The Journal of bone and joint surgery. American volume.

[9]  D. W. Jackson,et al.  THE ARTICULAR CARTILAGE REPAIR DILEMMA Symptomatic Articular Cartilage Degeneration , 2001 .

[10]  H. Bliddal,et al.  Guidance by ultrasound of intra-articular injections in the knee and hip joints. , 2001, Osteoarthritis and cartilage.

[11]  E. Balazs,et al.  Viscosupplementation: a new concept in the treatment of osteoarthritis. , 1993, The Journal of rheumatology. Supplement.