FLAIR diffusion-tensor MR tractography: comparison of fiber tracking with conventional imaging.

BACKGROUND AND PURPOSE Partial volume with CSF is known to contaminate the quantification of white matter anisotropy depicted by diffusion tensor imaging (DTI). We hypothesized that the FLAIR technique helps to improve DTI white matter tractography in the normal adult brain by eliminating CSF partial volume effects. METHODS Seven healthy adults aged 23-37 underwent both conventional and FLAIR DTI at 1.5T. Each subject was imaged five times. Neural fiber tractography was performed with both sequences by using two algorithms: a voxel-based method (EZ-tracing) with global seed points and another based on subvoxel tractography (tensor deflection) by using manual encircling of local seed points. Total volume of the fibers tracked was compared for the two types of images. RESULTS Fiber tracking was substantially most successful on FLAIR DTI near the lateral ventricles and the sulci, where CSF partial volume effects were likely present. Minor false tracts on FLAIR images, possibly due to a reduced signal-to-noise ratio, were found in regions relatively free of CSF contamination; however, they did not affect tracking of major periventricular white matter bundles, such as those related to the corpus callosum or the corona radiata. When we excluded false tracts, the FLAIR technique depicted an average of 17% more fibers in volume than conventional DTI in the periventricular regions (P < .0005, paired Student t test). CONCLUSION Despite the reduction of signal-to-noise ratio and longer imaging times, FLAIR improved tractography by eliminating CSF partial volume effects.

[1]  R. Henkelman Measurement of signal intensities in the presence of noise in MR images. , 1985, Medical physics.

[2]  J. Pearlman,et al.  CSF‐suppressed quantitative single‐shot diffusion imaging , 1991, Magnetic resonance in medicine.

[3]  N. Pelc,et al.  Brain motion: measurement with phase-contrast MR imaging. , 1992, Radiology.

[4]  D. Parker,et al.  Elimination of eddy current artifacts in diffusion‐weighted echo‐planar images: The use of bipolar gradients , 1997, Magnetic resonance in medicine.

[5]  P A Narayana,et al.  Cerebrospinal fluid‐suppressed high‐resolution diffusion imaging of human brain , 1997, Magnetic resonance in medicine.

[6]  P. Basser,et al.  A simplified method to measure the diffusion tensor from seven MR images , 1998, Magnetic resonance in medicine.

[7]  M. I. Smith,et al.  A study of rotationally invariant and symmetric indices of diffusion anisotropy. , 1999, Magnetic resonance imaging.

[8]  L R Schad,et al.  Comparison of diffusion anisotropy measurements in combination with the flair-technique. , 1999, Magnetic resonance imaging.

[9]  P. V. van Zijl,et al.  Three‐dimensional tracking of axonal projections in the brain by magnetic resonance imaging , 1999, Annals of neurology.

[10]  R. Bakshi,et al.  Intraventricular CSF pulsation artifact on fast fluid-attenuated inversion-recovery MR images: analysis of 100 consecutive normal studies. , 2000, AJNR. American journal of neuroradiology.

[11]  K Kojima,et al.  Applicability and advantages of flow artifact-insensitive fluid-attenuated inversion-recovery MR sequences for imaging the posterior fossa. , 2000, AJNR. American journal of neuroradiology.

[12]  P. Basser,et al.  In vivo fiber tractography using DT‐MRI data , 2000, Magnetic resonance in medicine.

[13]  P. Basser,et al.  Statistical artifacts in diffusion tensor MRI (DT‐MRI) caused by background noise , 2000, Magnetic resonance in medicine.

[14]  P. Basser,et al.  Water Diffusion Changes in Wallerian Degeneration and Their Dependence on White Matter Architecture , 2000 .

[15]  J. Hajnal,et al.  Reduction of CSF and blood flow artifacts on FLAIR images of the brain with k-space reordered by inversion time at each slice position (KRISP). , 2001, AJNR. American journal of neuroradiology.

[16]  J V Hajnal,et al.  FLAIR imaging using nonselective inversion pulses combined with slice excitation order cycling and k‐space reordering to reduce flow artifacts , 2001, Magnetic resonance in medicine.

[17]  D. Le Bihan,et al.  Diffusion tensor imaging: Concepts and applications , 2001, Journal of magnetic resonance imaging : JMRI.

[18]  D. Yousem,et al.  Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging. , 2002, AJNR. American journal of neuroradiology.

[19]  S. Warach,et al.  Cerebral spinal fluid contamination of the measurement of the apparent diffusion coefficient of water in acute stroke , 2002, Magnetic resonance in medicine.

[20]  Tsutomu Nakada,et al.  EZ-tracing: a new ready-to-use algorithm for magnetic resonance tractography , 2002, Journal of Neuroscience Methods.

[21]  I. Wilkinson,et al.  Study of the effect of CSF suppression on white matter diffusion anisotropy mapping of healthy human brain , 2002, Magnetic resonance in medicine.

[22]  V. Haughton,et al.  Diffusion tensor MR imaging in diffuse axonal injury. , 2002, AJNR. American journal of neuroradiology.

[23]  C. Liston,et al.  Fiber tracking using magnetic resonance diffusion tensor imaging and its applications to human brain development. , 2003, Mental retardation and developmental disabilities research reviews.

[24]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[25]  Derek K. Jones,et al.  Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI , 2003, Magnetic resonance in medicine.

[26]  A. Alexander,et al.  White matter tractography using diffusion tensor deflection , 2003, Human brain mapping.

[27]  Xiaoping P. Hu,et al.  Enhancing measured diffusion anisotropy in gray matter by eliminating CSF contamination with FLAIR , 2004, Magnetic resonance in medicine.

[28]  Lawrence H Staib,et al.  Anatomic dissection tractography: a new method for precise MR localization of white matter tracts. , 2004, AJNR. American journal of neuroradiology.