Development of a metrological atomic force microscope with a tip-tilting mechanism for 3D nanometrology

A metrological atomic force microscope with a tip-tilting mechanism (tilting-mAFM) has been developed to expand the capabilities of 3D nanometrology, particularly for high-resolution topography measurements at the surfaces of vertical sidewalls and for traceable measurements of nanodevice linewidth. In the tilting-mAFM, the probe tip is tilted from vertical to 16° at maximum such that the probe tip can touch and trace the vertical sidewall of a nanometer-scale structure; the probe of a conventional atomic force microscope cannot reach the vertical surface because of its finite cone angle. Probe displacement is monitored in three axes by using high-resolution laser interferometry, which is traceable to the SI unit of length. A central-symmetric 3D scanner with a parallel spring structure allows probe scanning with extremely low interaxial crosstalk. A unique technique for scanning vertical sidewalls was also developed and applied. The experimental results indicated high repeatability in the scanned profiles and sidewall angle measurements. Moreover, the 3D measurement of a line pattern was demonstrated, and the data from both sidewalls were successfully stitched together with subnanometer accuracy. Finally, the critical dimension of the line pattern was obtained.

[1]  Ludger Koenders,et al.  Recent developments in dimensional nanometrology using AFMs , 2011 .

[2]  Vladimir A. Ukraintsev,et al.  Review of reference metrology for nanotechnology: significance, challenges, and solutions , 2012 .

[3]  Theodore V. Vorburger,et al.  Subpixel image stitching for linewidth measurement based on digital image correlation , 2010 .

[4]  Vladimir Mancevski,et al.  Development of a dual-probe Caliper CD-AFM for near model-independent nanometrology , 2002, SPIE Advanced Lithography.

[5]  Gaoliang Dai,et al.  Development and characterisation of a new line width reference material , 2015 .

[6]  Ndubuisi G. Orji,et al.  Traceable calibration of a critical dimension atomic force microscope , 2011, Defense + Commercial Sensing.

[7]  Hyun-Woo Kim,et al.  Experimental investigation of the impact of LWR on sub-100-nm device performance , 2004, IEEE Transactions on Electron Devices.

[8]  Gaoliang Dai,et al.  New developments at Physikalisch Technische Bundesanstalt in three-dimensional atomic force microscopy with tapping and torsion atomic force microscopy mode and vector approach probing strategy , 2012 .

[9]  Alok Vaid,et al.  Metrology capabilities and needs for 7nm and 5nm logic nodes , 2017, Advanced Lithography.

[10]  Ichiko Misumi,et al.  Sub-hundred nanometre pitch measurements using an AFM with differential laser interferometers for designing usable lateral scales , 2005 .

[11]  Richard A. Allen,et al.  Traceable calibration of critical-dimension atomic force microscope linewidth measurements with nanometer uncertainty , 2005 .

[12]  Sebastien Ducourtieux,et al.  Development of a metrological atomic force microscope with minimized Abbe error and differential interferometer-based real-time position control , 2011 .

[13]  H. Kumar Wickramasinghe,et al.  Method for imaging sidewalls by atomic force microscopy , 1994 .

[14]  Toshio Ando,et al.  Active damping of the scanner for high-speed atomic force microscopy , 2005 .

[15]  Chao-Chang A. Chen,et al.  Precision Measurement of Sub-50 nm Linewidth by Stitching Double-Tilt Images , 2010 .

[16]  Ndubuisi G. Orji,et al.  Scanning probe microscope dimensional metrology at NIST , 2011 .

[17]  Satoshi Gonda,et al.  Periodic error evaluation system for linear encoders using a homodyne laser interferometer with 10 picometer uncertainty , 2018 .

[18]  Y. Lee,et al.  Introduction of next-generation 3D AFM for advanced process control , 2013, Advanced Lithography.

[19]  J Haycocks,et al.  Traceable calibration of transfer standards for scanning probe microscopy , 2005 .

[20]  Li-Chen Fu,et al.  Effective Tilting Angles for a Dual Probes AFM System to Achieve High-Precision Scanning , 2016, IEEE/ASME Transactions on Mechatronics.

[21]  R. Thalmann,et al.  Long-range AFM profiler used for accurate pitch measurements , 1998 .

[22]  Yueming Hua,et al.  Three-dimensional imaging of undercut and sidewall structures by atomic force microscopy. , 2011, The Review of scientific instruments.

[23]  Antti Lassila,et al.  Design and characterization of MIKES metrological atomic force microscope , 2010 .

[24]  Ndubuisi G. Orji,et al.  Interactions of higher order tip effects in critical dimension-AFM linewidth metrology , 2015 .

[25]  Gaoliang Dai,et al.  Reference nano-dimensional metrology by scanning transmission electron microscopy , 2013 .

[26]  Gregory A. Dahlen,et al.  Critical Dimension Atomic Force Microscopy for Sub-50-nm Microelectronics Technology Nodes , 2008 .

[27]  T. Terasawa,et al.  Side-wall measurement using tilt-scanning method in atomic force microscope , 2005, Digest of Papers Microprocesses and Nanotechnology 2005.

[28]  Peter Ebersbach,et al.  A holistic metrology approach: hybrid metrology utilizing scatterometry, CD-AFM, and CD-SEM , 2011, Advanced Lithography.

[29]  S. Gonda,et al.  REAL-TIME, INTERFEROMETRICALLY MEASURING ATOMIC FORCE MICROSCOPE FOR DIRECT CALIBRATION OF STANDARDS , 1999 .

[30]  H.-U. Danzebrink,et al.  Advances in Scanning Force Microscopy for Dimensional Metrology , 2006 .

[31]  Hui Zhou,et al.  Improving optical measurement accuracy using multi-technique nested uncertainties , 2009, Advanced Lithography.

[32]  Wei Chu,et al.  An image stitching method to eliminate the distortion of the sidewall in linewidth measurement , 2004, SPIE Advanced Lithography.

[33]  Gaoliang Dai,et al.  Measurements of CD and sidewall profile of EUV photomask structures using CD-AFM and tilting-AFM , 2014 .

[34]  Hui Xie,et al.  Advances in the atomic force microscopy for critical dimension metrology , 2016 .

[35]  Qi Chen,et al.  Improvement in metrology on new 3D-AFM platform , 2008, Photomask Technology.

[36]  Ronald G. Dixson,et al.  Comparison of line width calibration using critical dimension atomic force microscopes between PTB and NIST , 2017 .

[37]  Gaoliang Dai,et al.  Metrological large range scanning probe microscope , 2004 .

[38]  Hui Xie,et al.  Development of Three-Dimensional Atomic Force Microscope for Sidewall Structures Imaging With Controllable Scanning Density , 2016, IEEE/ASME Transactions on Mechatronics.