The Design of Remote Monitoring System for Indoor Electrical Safety
暂无分享,去创建一个
Causes of electrical fires have great variety. In view of the main, this paper explores the algorithm of fault arc detection and the method of electric appliance identification, and briefly shows the overall design of the monitoring system. The judging threshold of fault arc can be carried out through building an AR model of normal current signal and calculating the coefficients of the AR model with the third-order Burg algorithm. The existence of fault arc can be determined by the squared Euclid distance between the threshold and the coefficients of current signal. The pattern recognize based on the Fourier series of current signal as characteristic values can be used as Electrical appliances identification methods combined with the power of appliance.
[1] Li Yicheng. Error Analysis of Sampling Computation Method for RMS Measurement , 2008 .
[2] Chen Degui. The Arc-Fault Circuit Interrupter——A New Low Voltage Protection Apparatus , 2007 .
[3] Paolo F. Fantoni,et al. Wire System Aging Assessment and Condition Monitoring Using Line Resonance Analysis (LIRA) , 2006 .
[4] Steven B. Leeb,et al. Power signature analysis , 2003 .