Microfluidic mixing for sperm activation and motility analysis of pearl Danio zebrafish.

Sperm viability in aquatic species is increasingly being evaluated by motility analysis via computer-assisted sperm analysis (CASA) following activation of sperm with manual dilution and mixing by hand. User variation can limit the speed and control over the activation process, preventing consistent motility analysis. This is further complicated by the short interval (i.e., less than 15 s) of burst motility in these species. The objectives of this study were to develop a staggered herringbone microfluidic mixer to: 1) activate small volumes of Danio pearl zebrafish (Danio albolineatus) sperm by rapid mixing with diluent, and 2) position sperm in a viewing chamber for motility evaluation using a standard CASA system. A herringbone micromixer was fabricated in polydimethylsiloxane (PDMS) to yield high quality smooth surfaces. Based on fluorescence microscopy, mixing efficiency exceeding 90% was achieved within 5 s for a range of flow rates (from 50 to 250 μL/h), with a correlation of mixing distances and mixing efficiency. For example, at the nominal flow rate of 100 μL/h, there was a significant difference in mixing efficiency between 3.5 mm (75±4%; mean±SD) and 7 mm (92±2%; P=0.002). The PDMS micromixer, integrated with standard volumetric slides, demonstrated activation of fresh zebrafish sperm with reduced user variation, greater control, and without morphologic damage to sperm. Analysis of zebrafish sperm viability by CASA revealed a statistically higher motility rate for activation by micromixing (56±4%) than manual activation (45±7%; n=5, P=0.011). This micromixer represented a first step in streamlining methods for consistent, rapid assessment of sperm quality for zebrafish and other aquatic species. The capability to rapidly activate sperm and consistently measure motility with CASA using the PDMS micromixer described herein will improve studies of germplasm physiology and cryopreservation.

[1]  P. Carmeliet,et al.  Zebrafish and Xenopus tadpoles: small animal models to study angiogenesis and lymphangiogenesis. , 2006, Experimental cell research.

[2]  J. Eisen,et al.  Headwaters of the zebrafish — emergence of a new model vertebrate , 2002, Nature Reviews Genetics.

[3]  H. Bau,et al.  A minute magneto hydro dynamic (MHD) mixer , 2001 .

[4]  S. Takayama,et al.  Microfluidic applications for andrology. , 2005, Journal of andrology.

[5]  Huiping Yang,et al.  High-throughput cryopreservation of spermatozoa of blue catfish (Ictalurus furcatus): Establishment of an approach for commercial-scale processing. , 2011, Cryobiology.

[6]  M. Kent,et al.  The State of the Art of the Zebrafish Model for Toxicology and Toxicologic Pathology Research—Advantages and Current Limitations , 2003, Toxicologic pathology.

[7]  Z. C. Feng,et al.  Development of sorting, aligning, and orienting motile sperm using microfluidic device operated by hydrostatic pressure , 2007 .

[8]  N. Hart,et al.  Scanning electron microscope studies of sperm incorporation into the zebrafish (Brachydanio) egg. , 1987, The Journal of experimental zoology.

[9]  Dimitris E. Nikitopoulos,et al.  High-precision micromilling for low-cost fabrication of metal mold masters , 2006, SPIE MOEMS-MEMS.

[10]  T. Tiersch,et al.  Current status of sperm cryopreservation in biomedical research fish models: zebrafish, medaka, and Xiphophorus. , 2009, Comparative biochemistry and physiology. Toxicology & pharmacology : CBP.

[11]  D. Beebe,et al.  Sperm motion in a microfluidic fertilization device , 2008, Biomedical microdevices.

[12]  Tijani Gharbi,et al.  A full micro-fluidic system for single oocyte manipulation including an optical sensor for cell maturity estimation and fertilisation indication , 2007 .

[13]  A. Christensen,et al.  Characterization of interconnects used in PDMS microfluidic systems , 2005 .

[14]  T. Johnson,et al.  Rapid microfluidic mixing. , 2002, Analytical chemistry.

[15]  Thomas Laurell,et al.  Acoustic differential extraction for forensic analysis of sexual assault evidence. , 2009, Analytical chemistry.

[16]  T. R. Tiersch,et al.  Biophysics of zebrafish (Danio rerio) sperm. , 2008, Cryobiology.

[17]  D. Beebe,et al.  Physics and applications of microfluidics in biology. , 2002, Annual review of biomedical engineering.

[18]  S. Takayama,et al.  Gamete and embryo isolation and culture with microfluidics. , 2007, Theriogenology.

[19]  Steven A. Soper,et al.  Evaluation of micromilled metal mold masters for the replication of microchip electrophoresis devices , 2006 .

[20]  Nadine Aubry,et al.  Electro-hydrodynamic micro-fluidic mixer. , 2003, Lab on a chip.

[21]  Shuichi Takayama,et al.  IVF within microfluidic channels requires lower total numbers and lower concentrations of sperm. , 2006, Human reproduction.

[22]  M. Iguer-ouada,et al.  Computer assisted semen analyzers in andrology research and veterinary practice. , 2002, Theriogenology.

[23]  T. Tiersch,et al.  Determination of sperm concentration for small-bodied biomedical model fishes by use of microspectrophotometry. , 2010, Zebrafish.

[24]  Shuichi Takayama,et al.  A surface-modified sperm sorting device with long-term stability , 2006, Biomedical microdevices.

[25]  Patrick S Doyle,et al.  Compressed-air flow control system. , 2011, Lab on a chip.

[26]  Steven L Neale,et al.  Motile and non-motile sperm diagnostic manipulation using optoelectronic tweezers. , 2010, Lab on a chip.

[27]  Shuichi Takayama,et al.  Passively driven integrated microfluidic system for separation of motile sperm. , 2003, Analytical chemistry.

[28]  Nam-Trung Nguyen,et al.  Micromixers?a review , 2005 .

[29]  V. Hessel,et al.  Micromixers—a review on passive and active mixing principles , 2005 .

[30]  Robin H. Liu,et al.  Bubble-induced acoustic micromixing. , 2002, Lab on a chip.

[31]  S. Takayama,et al.  Rethinking gamete/embryo isolation and culture with microfluidics. , 2003, Human reproduction update.

[32]  J. Cosson,et al.  Sperm motility in fishes. (II) Effects of ions and osmolality: A review , 2006, Cell biology international.

[33]  Daniel T Chiu,et al.  Disposable microfluidic devices: fabrication, function, and application. , 2005, BioTechniques.

[34]  P. Yager,et al.  A practical guide to the staggered herringbone mixer. , 2008, Lab on a chip.

[35]  G. Whitesides,et al.  Microfabrication meets microbiology , 2007, Nature Reviews Microbiology.

[36]  Patricia M. Mazik,et al.  Cryopreservation in aquatic species , 2000 .

[37]  T. Tiersch,et al.  Development of a simplified and standardized protocol with potential for high-throughput for sperm cryopreservation in zebrafish Danio rerio. , 2007, Theriogenology.

[38]  Nadine Aubry,et al.  Enhancement of microfluidic mixing using time pulsing. , 2003, Lab on a chip.

[39]  Steven A. Soper,et al.  Titer plate formatted continuous flow thermal reactors for high throughput applications: fabrication and testing , 2010 .

[40]  K. Naruse,et al.  Application of a microfluidic sperm sorter to the in-vitro fertilization of porcine oocytes reduced the incidence of polyspermic penetration. , 2010, Theriogenology.

[41]  L. Zon,et al.  Zebrafish: a model system for the study of human disease. , 2000, Current opinion in genetics & development.

[42]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[43]  Jerome P Ferrance,et al.  Separation of sperm and epithelial cells in a microfabricated device: potential application to forensic analysis of sexual assault evidence. , 2005, Analytical chemistry.

[44]  R. Ingermann,et al.  Development of a novel CASA system based on open source software for characterization of zebrafish sperm motility parameters. , 2007, Theriogenology.

[45]  I. Mezić,et al.  Chaotic Mixer for Microchannels , 2002, Science.

[46]  Kwang-Yong Kim,et al.  Shape optimization of a micromixer with staggered-herringbone grooves patterned on opposite walls , 2010 .