Is the Collapsibility Index of the Inferior Vena Cava an Accurate Predictor for the Early Detection of Intravascular Volume Change?

ABSTRACT The ultrasonographic evaluation of inferior vena cava (IVC) parameters, particularly the collapsibility index (CI), has been widely used in the assessment of the fluid responsiveness of critically ill patients, but the results are conflicting. In this study, we aimed to investigate the early change in CI after increased intravascular volume (IVV) induced by passive leg raising (PLR). A total of 145 healthy volunteers over 18 years old were enrolled between September and December in 2015. Before and 2 min after PLR, the maximum and minimum IVC diameters (maxIVC and minIVC) were measured by color Doppler ultrasonography, and the difference in CI (&Dgr;CI) was calculated. The heart rate (HR) and noninvasive mean arterial pressure (MAP) were also monitored. We found that there was a significant increase in the mean maxIVC and minIVC values and a reduction in CI. Nevertheless, no significant differences in HR or MAP were observed before or 2 min after PLR. The baseline CI had no relationship with individual characteristics and a multiple linear regression analysis of the &Dgr;CI and individual characteristics showed that age, baseline CI, and BMI were independent variables for &Dgr;CI. In conclusion, IVC-CI measured by ultrasound is useful for the detection of early IVV change induced by 2 min PLR. However, its ability to detect the increased IVV value is influenced by age, BMI, and baseline CI. Moreover, only 50.3% of the subjects had an IVC-CI reduction of more than 10%, making IVC-CI of little value for clinical applications, due to its poor sensitivity.

[1]  R. Epstein,et al.  Preoperative inferior vena cava collapsibility is a poor marker of intraoperative fluid requirements and hypotension: A pilot study , 2019, Journal of anaesthesiology, clinical pharmacology.

[2]  Wanchun Tang,et al.  Impact of body characteristics on ultrasound-measured inferior vena cava parameters in Chinese children , 2019, Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas.

[3]  M. Dalley,et al.  Point-of-Care Ultrasound Identifies Decompensated Heart Failure in a Young Male with Methamphetamine-Associated Cardiomyopathy Presenting in Severe Sepsis to the Emergency Department , 2018, Case reports in emergency medicine.

[4]  Anding Xu,et al.  Impact of individual characteristics on sonographic IVC diameter and the IVC diameter/aorta diameter index. , 2015, The American journal of emergency medicine.

[5]  Dennis Y Kim,et al.  Flat or fat? Inferior vena cava ratio is a marker for occult shock in trauma patients. , 2014, The Journal of surgical research.

[6]  J. Dunne,et al.  Inferior vena cava size is not associated with shock following injury , 2014, The journal of trauma and acute care surgery.

[7]  E. E. Ünlüer,et al.  Monitoring the response to treatment of acute heart failure patients by ultrasonographic inferior vena cava collapsibility index. , 2014, The American journal of emergency medicine.

[8]  E. Sloth,et al.  Ultrasound of the inferior vena cava does not predict hemodynamic response to early hemorrhage. , 2013, The Journal of emergency medicine.

[9]  J. Whelan,et al.  Flat Inferior Vena Cava: Indicator of Poor Prognosis in Trauma and Acute Care Surgery Patients , 2012, The American surgeon.

[10]  H. Norton,et al.  Comparison of serial qualitative and quantitative assessments of caval index and left ventricular systolic function during early fluid resuscitation of hypotensive emergency department patients. , 2011, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[11]  R. Cydulka,et al.  Ultrasound does not detect early blood loss in healthy volunteers donating blood. , 2011, The Journal of emergency medicine.

[12]  T. Sakamoto,et al.  Predicting the Development of Anemia by Measuring the Diameter of the Inferior Vena Cava for Children With Blunt Injuries , 2008, Pediatric emergency care.

[13]  J. Teboul,et al.  The respiratory variation in inferior vena cava diameter as a guide to fluid therapy , 2004, Intensive Care Medicine.

[14]  Antoine Vieillard-Baron,et al.  Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients , 2004, Intensive Care Medicine.

[15]  Y. Amoateng-Adjepong,et al.  Negative fluid balance predicts survival in patients with septic shock: a retrospective pilot study. , 2000, Chest.

[16]  Y. Asano,et al.  Change in Inferior Vena Caval Diameter Detected by Ultrasonography During and After Hemodialysis , 1995, ASAIO journal.

[17]  N. Schiller,et al.  Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava. , 1990, The American journal of cardiology.

[18]  R. Jeffrey,et al.  The collapsed inferior vena cava: CT evidence of hypovolemia. , 1988, AJR. American journal of roentgenology.

[19]  M. Oberholzer,et al.  Influence of age on pulmonary haemodynamics at rest and during supine exercise. , 1983, Clinical science.

[20]  F. Dunn,et al.  Borderline Hypertension and Obesity: Two Prehypertensive States with Elevated Cardiac Output , 1982, Circulation.

[21]  H. Natori,et al.  Ultrasonographic evaluation of ventilatory effect on inferior vena caval configuration. , 1979, The American review of respiratory disease.

[22]  B. Cander,et al.  Inferior vena cava diameter as a marker of early hemorrhagic shock: a comparative study. , 2010, Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES.

[23]  M. Stone,et al.  Inferior vena cava percentage collapse during respiration is affected by the sampling location: an ultrasound study in healthy volunteers. , 2010, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[24]  Matthew Lyon,et al.  Sonographic measurement of the inferior vena cava as a marker of blood loss. , 2005, The American journal of emergency medicine.

[25]  R A Nishimura,et al.  Assessment of right atrial pressure with 2-dimensional and Doppler echocardiography: a simultaneous catheterization and echocardiographic study. , 2000, Mayo Clinic proceedings.