Aerosol Particle Number Concentration Measurements in Five European Cities Using TSI-3022 Condensation Particle Counter over a Three-Year Period during Health Effects of Air Pollution on Susceptible Subpopulations

Abstract In this study, long-term aerosol particle total number concentration measurements in five metropolitan areas across Europe are presented. The measurements have been carried out in Augsburg, Barcelona, Helsinki, Rome, and Stockholm using the same instrument, a condensation particle counter (TSI model 3022). The results show that in all of the studied cities, the winter concentrations are higher than the summer concentrations. In Helsinki and in Stockholm, winter concentrations are higher by a factor of two and in Augsburg almost by a factor of three compared with summer months. The winter maximum of the monthly average concentrations in these cities is between 10,000 cm-3 and 20,000 cm-3, whereas the summer min is ˜;5000–6000 cm-3. In Rome and in Barcelona, the winters are more polluted compared with summers by as much as a factor of 4–10. The winter maximum in both Rome and Barcelona is close to 100,000 cm-3, whereas the summer minimum is >10,000 cm-3. During the weekdays the maximum of the hourly average concentrations in all of the cities is detected during the morning hours between 7 and 10 a.m. The evening maxima were present in Barcelona, Rome, and Augsburg, but these were not as pronounced as the morning ones. The daily maxima in Helsinki and Stockholm are close or even lower than the daily minima in the more polluted cities. The concentrations between these two groups of cities are different with a factor of about five during the whole day. The study pointed out the influence of the selection of the measurement site and the configuration of the sampling line on the observed concentrations.

[1]  Güunter Oberdürster Toxicology of ultrafine particles: in vivo studies , 2000, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[2]  D. Dockery,et al.  Epidemiology of Particle Effects , 1999 .

[3]  Pasi Aalto,et al.  Atmospheric Chemistry and Physics Discussions , 2001 .

[4]  Bert Brunekreef,et al.  Concentrations of ultrafine, fine and PM2.5 particles in three European cities , 2001 .

[5]  J. Seinfeld,et al.  Atmospheric Chemistry and Physics: From Air Pollution to Climate Change , 1997 .

[6]  Annette Peters,et al.  Epidemiological evidence of the effects of ultrafine particle exposure , 2000, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[7]  J Pekkanen,et al.  Effects of ultrafine and fine particles in urban air on peak expiratory flow among children with asthmatic symptoms. , 1997, Environmental research.

[8]  Gilmore J. Sem,et al.  Design and performance characteristics of three continuous-flow condensation particle counters: a summary , 2002 .

[9]  Klaus Willeke,et al.  Aerosol Measurement: Principles, Techniques, and Applications , 2001 .

[10]  Robert L. Maynard,et al.  Air Pollution and Health , 2006 .

[11]  B. Wehner,et al.  Particle number size distributions in a street canyon and their transformation into the urban-air background: measurements and a simple model study , 2002 .

[12]  B. Weiss,et al.  Association of particulate air pollution and acute mortality: involvement of ultrafine particles? , 1995, Inhalation toxicology.

[13]  Günter Oberdörster,et al.  Toxicology of ultrafine particles: in vivo studies , 2000 .

[14]  Kaarle Hämeri,et al.  Spatial variation of aerosol number concentration in Helsinki city , 1999 .

[15]  Peter H. McMurry,et al.  The History of Condensation Nucleus Counters , 2000 .

[16]  Roy M. Harrison,et al.  Primary particle formation from vehicle emissions during exhaust dilution in the roadside atmosphere , 2003 .

[17]  David Sinclair,et al.  A continuous flow condensation nucleus counter , 1975 .

[18]  F. R. Quant,et al.  Performance of condensation particle counters with three continuous-flow designs , 1992 .

[19]  R. Burnett,et al.  Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution. , 2002, JAMA.

[20]  U. Epa Air Quality Criteria for Particulate Matter , 1996 .

[21]  Jugal K. Agarwal,et al.  Continuous flow, single-particle-counting condensation nucleus counter , 1980 .

[22]  Ernest Weingartner,et al.  Fine and ultrafine particles in the Zürich (Switzerland) area measured with a mobile laboratory: an assessment of the seasonal and regional variation throughout a year , 2003 .

[23]  D. Dockery,et al.  Acute respiratory effects of particulate air pollution. , 1994, Annual review of public health.

[24]  A. Wiedensohler,et al.  Long term measurements of submicrometer urban aerosols: statistical analysis for correlations with meteorological conditions and trace gases , 2002 .