Water recovery from humidified waste gas streams: Quality control using membrane condenser technology

Abstract In this work “membrane condenser” is utilized for the selective recovery of evaporated waste water from industrial gases and for the control of the composition of the recovered liquid water. A simulation study of the process has been developed for predicting the membrane-based process performance. The achieved results indicate that feed flow rate ( Q Feed ), interfacial membrane area ( A Membrane ), the ratio Q Feed / A Membrane , the temperature difference (Δ T ) between the fed flue gas T feed and the membrane module are the parameters controlling the process. In particular, the amount of recovered water rises at increasing Δ T and Q Feed / A Membrane , whereas its quality is made worse at increasing Δ T and Q Feed . The data obtained have been also supported by an experimental study of the process, confirming the validity of the simulation study and its suitability for a screening of the operative conditions to be chosen in a membrane condenser.

[1]  K. Y. Qu,et al.  Experimental study on mass transfer performances of cross flow dehumidifier using liquid desiccant , 2006 .

[2]  Alex Hoehn,et al.  Membrane porosity and hydrophilic membrane-based dehumidification performance , 2000 .

[3]  Dongsheng Zhu,et al.  Thermodynamic modeling of a novel air dehumidification system , 2005, Energy and Buildings.

[4]  Bruce C. Folkedahl,et al.  Water Extraction from Coal-Fired Power Plant Flue Gas , 2006 .

[5]  F. Adamczyk,et al.  Retrofit of a flue gas heat recovery system at the mehrum power plant: An example of power plant lifetime evaluation in practise , 2004 .

[6]  Don W. Green,et al.  Perry's Chemical Engineers' Handbook , 2007 .

[7]  Anna Magrini,et al.  On the application of a membrane air—liquid contactor for air dehumidification , 1997 .

[8]  Enrico Drioli,et al.  ECTFE membrane preparation for recovery of humidified gas streams using membrane condenser , 2014 .

[9]  P Scovazzo,et al.  Hydrophilic membrane-based humidity control. , 1998, Journal of membrane science.

[10]  P. Brimblecombe,et al.  Solubility of ammonia in pure aqueous and multicomponent solutions , 1989 .

[11]  R. B. Jackson,et al.  Water in a changing world , 2001 .

[12]  E. Drioli,et al.  Membrane Condenser as a New Technology for Water Recovery from Humidified “Waste” Gaseous Streams , 2013 .

[13]  Sabah A. Abdul-Wahab,et al.  Air dehumidification by triethylene glycol desiccant in a packed column , 2004 .

[14]  Akira Ito,et al.  Dehumidification of air by a hygroscopic liquid membrane supported on surface of a hydrophobic microporous membrane , 2000 .

[15]  H. Maahs Sulfur‐Dioxide/Water Equilibria Between 0° and 50°C. An Examination of Data at Low Concentrations , 2013 .

[16]  Enrico Drioli,et al.  Waste Gaseous Streams: From Environmental Issue to Source of Water by Using Membrane Condensers , 2014 .

[17]  Matthias Wessling,et al.  Flue gas dehydration using polymer membranes , 2008 .