An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component.

The use of plate-and-cable constructs to treat periprosthetic fractures around a well-fixed femoral component in total hip replacements has been reported to have high rates of failure. Our aim was to evaluate the results of a surgical treatment algorithm to use these lateral constructs reliably in Vancouver type-B1 and type-C fractures. The joint was dislocated and the stability of the femoral component was meticulously evaluated in 45 type-B1 fractures. This led to the identification of nine (20%) unstable components. The fracture was considered to be suitable for single plate-and-cable fixation by a direct reduction technique if the integrity of the medial cortex could be restored. Union was achieved in 29 of 30 fractures (97%) at a mean of 6.4 months (3 to 30) in 29 type-B1 and five type-C fractures. Three patients developed an infection and one construct failed. Using this algorithm plate-and-cable constructs can be used safely, but indirect reduction with minimal soft-tissue damage could lead to shorter times to union and lower rates of complications.

[1]  F. Haddad,et al.  European validation of the Vancouver classification of periprosthetic proximal femoral fractures. , 2008, The Journal of bone and joint surgery. British volume.

[2]  R. Zdero,et al.  Biomechanical evaluation of periprosthetic femoral fracture fixation. , 2008, The Journal of bone and joint surgery. American volume.

[3]  J. Cooper,et al.  Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: a report on 12 patients. , 2007, Injury.

[4]  B. McGrory,et al.  Fixation of Vancouver B1 peri-prosthetic fractures by broad metal plates without the application of strut allografts. , 2006, The Journal of bone and joint surgery. British volume.

[5]  J. Borrelli,et al.  Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. , 2006, The Journal of bone and joint surgery. American volume.

[6]  P. Herberts,et al.  Three hundred and twenty-one periprosthetic femoral fractures. , 2006, The Journal of bone and joint surgery. American volume.

[7]  Erik N. Kubiak,et al.  Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. , 2006, The Journal of trauma.

[8]  F. Kummer,et al.  Fixation of Periprosthetic Femoral Shaft Fractures Associated With Cemented Femoral Stems: A Biomechanical Comparison of Locked Plating and Conventional Cable Plates , 2006, Journal of orthopaedic trauma.

[9]  P. Herberts,et al.  Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the Swedish National Hip Arthroplasty Register. , 2005, The Journal of arthroplasty.

[10]  J. Parvizi,et al.  Treatment protocol for proximal femoral periprosthetic fractures. , 2004, The Journal of bone and joint surgery. American volume.

[11]  S. G. Haidar Dall-Miles plates for periprosthetic femoral fractures a critical review of 16 cases. , 2004, Injury.

[12]  F. Haddad,et al.  Dall-Miles plates for periprosthetic femoral fractures , 2003 .

[13]  E. Tsiridis,et al.  Percutaneous plate fixation for periprosthetic femoral fractures--a preliminary report. , 2002, Injury.

[14]  D. Berry,et al.  Periprosthetic Femoral Fractures Around Well-Fixed Implants: Use of Cortical Onlay Allografts with or without a Plate , 2002, The Journal of bone and joint surgery. American volume.

[15]  Z. Xiang,et al.  [Locking compression plate fixation for periprosthetic femoral fracture]. , 2002, Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery.

[16]  B. Masri,et al.  Periprosthetic fractures: an operative algorithm. , 2001, Orthopedics.

[17]  R. Koka,et al.  Dall-Miles cable and plate fixation for the treatment of peri-prosthetic femoral fractures-analysis of results in 13 cases. , 2001, Injury.

[18]  F. Kummer,et al.  Fixation of Periprosthetic Femoral Shaft Fractures: A Biomechanical Comparison of Two Techniques , 2001, Journal of orthopaedic trauma.

[19]  F. Kummer,et al.  Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. , 2000, The Journal of arthroplasty.

[20]  S. Kamineni,et al.  Peri-prosthetic femoral shaft fractures treated with plate and cable fixation. , 1999, Injury.

[21]  B. Masri,et al.  The treatment of periprosthetic fractures of the femur using cortical onlay allograft struts. , 1999, The Orthopedic clinics of North America.

[22]  R. K. Beals,et al.  Fractures of the femur after hip replacement: the Oregon experience. , 1999, The Orthopedic clinics of North America.

[23]  H. Chandler,et al.  The role of allografts in the treatment of periprosthetic femoral fractures. , 1997, Instructional course lectures.

[24]  F. Haddad,et al.  The Dall-Miles cable and plate system for periprosthetic femoral fractures. , 1997, Injury.

[25]  L. Dorr,et al.  Treatment of fractures about hip prostheses with compression plating. , 1992, The Journal of arthroplasty.

[26]  E. Chao,et al.  Bypassing femoral cortical defects with cemented intramedullary stems , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[27]  E. J. Zenni,et al.  Ogden plate and other fixations for fractures complicating femoral endoprostheses. , 1988, Clinical orthopaedics and related research.

[28]  H. Amstutz,et al.  Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty. , 1984, The Journal of bone and joint surgery. American volume.

[29]  R. H. Turner,et al.  Femoral fractures in conjunction with total hip replacement. , 1975, The Journal of bone and joint surgery. American volume.

[30]  G. Garellick,et al.  Risk factors for failure after treatment of a periprosthetic fracture of the femur. , 2006, The Journal of bone and joint surgery. British volume.

[31]  T. H.,et al.  The Journal of Bone and Joint Surgery , 2006 .

[32]  Thomas R Oxland,et al.  A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures. , 2005, Clinical biomechanics.

[33]  S. Agarwal,et al.  Outcome following stabilization of type B1 periprosthetic femoral fractures. , 2005, The Journal of arthroplasty.

[34]  B. Masri,et al.  Cable plates and onlay allografts in periprosthetic femoral fractures after hip replacement: laboratory and clinical observations. , 2004, Instructional course lectures.

[35]  I. Learmonth The management of periprosthetic fractures around the femoral stem. , 2004, The Journal of bone and joint surgery. British volume.

[36]  L. Munuera,et al.  Femoral shaft fractures after cemented total hip arthroplasty , 2004, International Orthopaedics.

[37]  B. Masri,et al.  The reliability and validity of the Vancouver classification of femoral fractures after hip replacement. , 2000, The Journal of arthroplasty.

[38]  A. Nanu,et al.  Dall-Miles plating for periprosthetic B1 fractures of the femur. , 2000, The Journal of arthroplasty.

[39]  B. Masri,et al.  Fractures of the femur after hip replacement. , 1995, Instructional course lectures.