A new virtual ring-based system matrix generator for iterative image reconstruction in high resolution small volume PET systems

A common approach to improving the spatial resolution of small animal PET scanners is to reduce the size of scintillation crystals and/or employ high resolution pixellated semiconductor detectors. The large number of detector elements results in the system matrix--an essential part of statistical iterative reconstruction algorithms--becoming impractically large. In this paper, we propose a methodology for system matrix modelling which utilises a virtual single-layer detector ring to greatly reduce the size of the system matrix without sacrificing precision. Two methods for populating the system matrix are compared; the first utilises a geometrically-derived system matrix based on Siddon's ray tracer method with the addition of an accurate detector response function, while the second uses Monte Carlo simulation to populate the system matrix. The effectiveness of both variations of the proposed technique is demonstrated via simulations of PETiPIX, an ultra high spatial resolution small animal PET scanner featuring high-resolution DoI capabilities, which has previously been simulated and characterised using classical image reconstruction methods. Compression factors of 5 x 10(7) and 2.5 x 10(7)are achieved using this methodology for the system matrices produced using the geometric and Monte Carlo-based approaches, respectively, requiring a total of 0.5-1.2 GB of memory-resident storage. Images reconstructed from Monte Carlo simulations of various point source and phantom models, produced using system matrices generated via both geometric and simulation methods, are used to evaluate the quality of the resulting system matrix in terms of achievable spatial resolution and the CRC, CoV and CW-SSIM index image quality metrics. The Monte Carlo-based system matrix is shown to provide the best image quality at the cost of substantial one-off computational effort and a lower (but still practical) compression factor. Finally, a straightforward extension of the virtual ring method to a three dimensional virtual cylinder is demonstrated using a 3D DoI PET scanner.

[1]  Carlos Lacasta,et al.  Performance evaluation of a very high resolution small animal PET imager using silicon scatter detectors , 2007, Physics in medicine and biology.

[2]  R L Siddon,et al.  Scatter integration with right triangular fields. , 1985, Medical physics.

[3]  Rangaraj M. Rangayyan,et al.  Analysis of Structural Similarity in Mammograms for Detection of Bilateral Asymmetry , 2015, IEEE Transactions on Medical Imaging.

[4]  Jian Zhou,et al.  Fast and efficient fully 3D PET image reconstruction using sparse system matrix factorization with GPU acceleration , 2011, Physics in medicine and biology.

[5]  Steven G. Ross,et al.  Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction , 2010, IEEE Transactions on Medical Imaging.

[6]  W. Moses Fundamental Limits of Spatial Resolution in PET. , 2011, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[7]  Mitra Safavi-Naeini,et al.  A Prototype high resolution SiPM-based PET system for small volume imaging , 2013 .

[8]  Iwan Kawrakow,et al.  SU‐GG‐I‐109: Using EGSnrc Within GATE to Improve the Efficiency Of positron Emission Tomography Simulations , 2008 .

[9]  Nadim Joni Shah,et al.  Fully-3D PET Image Reconstruction Using Scanner-Independent, Adaptive Projection Data and Highly Rotation-Symmetric Voxel Assemblies , 2011, IEEE Transactions on Medical Imaging.

[10]  J L Rubio,et al.  Efficient methodologies for system matrix modelling in iterative image reconstruction for rotating high-resolution PET , 2010, Physics in medicine and biology.

[11]  Yong Choi,et al.  Simulation studies on depth of interaction effect correction using a Monte Carlo computed system matrix for brain positron emission tomography , 2012, Comput. Methods Programs Biomed..

[12]  Long Zhang,et al.  Fast and memory-efficient Monte Carlo-based image reconstruction for whole-body PET. , 2010, Medical physics.

[13]  H. Murayama,et al.  First Human Brain Imaging by the jPET-D4 Prototype With a Pre-Computed System Matrix , 2008, IEEE Transactions on Nuclear Science.

[14]  M. Rafecas,et al.  Effect of noise in the probability matrix used for statistical reconstruction of PET data , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[15]  Craig S. Levin,et al.  Fast, Accurate and Shift-Varying Line Projections for Iterative Reconstruction Using the GPU , 2009, IEEE Transactions on Medical Imaging.

[16]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[17]  Magdalena Rafecas,et al.  Comparison of basis functions for 3D PET reconstruction using a Monte Carlo system matrix , 2012, Physics in medicine and biology.

[18]  Robert Andritschke,et al.  SiliPET: an ultra-high resolution design of a small animal PET scanner based on stacks of double-sided silicon strip detector , 2007 .

[19]  R. Leahy,et al.  High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner. , 1998, Physics in medicine and biology.

[20]  M. Rafecas,et al.  Use of a Monte Carlo-based probability matrix for 3-D iterative reconstruction of MADPET-II data , 2004, IEEE Transactions on Nuclear Science.

[21]  Simon R. Cherry,et al.  Quantitative, Simultaneous PET/MRI for Intratumoral Imaging with an MRI-Compatible PET Scanner , 2012, The Journal of Nuclear Medicine.

[22]  Simon R Cherry,et al.  Small-animal preclinical nuclear medicine instrumentation and methodology. , 2008, Seminars in nuclear medicine.

[23]  Jinyi Qi,et al.  Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurements , 2009, Physics in medicine and biology.

[24]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[25]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[26]  E. Veklerov,et al.  MLE reconstruction of a brain phantom using a Monte Carlo transition matrix and a statistical stopping rule , 1988 .

[27]  Eric C Frey,et al.  Development of a 4-D digital mouse phantom for molecular imaging research. , 2004, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.

[28]  Pat Zanzonico,et al.  Routine Quality Control of Clinical Nuclear Medicine Instrumentation: A Brief Review* , 2008, Journal of Nuclear Medicine.

[29]  Brian F. Hutton,et al.  A feasibility study of PETiPIX: an ultra high resolution small animal PET scanner , 2013 .

[30]  C. Levin,et al.  Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography , 2007, Physics in medicine and biology.

[31]  Keishi Kitamura,et al.  Transaxial system models for jPET-D4 image reconstruction , 2005, Physics in medicine and biology.

[32]  J J Vaquero,et al.  FIRST: Fast Iterative Reconstruction Software for (PET) tomography. , 2006, Physics in medicine and biology.

[33]  Gianluigi Zanetti,et al.  Multi-ray-based system matrix generation for 3D PET reconstruction , 2008, Physics in medicine and biology.

[34]  Zhou Wang,et al.  Complex Wavelet Structural Similarity: A New Image Similarity Index , 2009, IEEE Transactions on Image Processing.

[35]  D. McElroy,et al.  Use of a Monte-Carlo based probability matrix for 3D iterative reconstruction of MADPET-II data , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[36]  Pablo Aguiar,et al.  Geometrical and Monte Carlo projectors in 3D PET reconstruction. , 2010, Medical physics.

[37]  Jürgen Scheins,et al.  Analytical calculation of volumes-of-intersection for iterative, fully 3-D PET reconstruction , 2006, IEEE Transactions on Medical Imaging.

[38]  C.A. Bouman,et al.  Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner , 2003, IEEE Transactions on Medical Imaging.

[39]  Richard Rhoad,et al.  Geometry: For Enjoyment and Challenge , 1981 .

[40]  E U Mumcuoğlu,et al.  Bayesian reconstruction of PET images: methodology and performance analysis. , 1996, Physics in medicine and biology.

[41]  Gernot Riedel,et al.  Mapping Changes in Mouse Brain Metabolism with PET/CT , 2013, The Journal of Nuclear Medicine.

[42]  G. De Geronimo,et al.  Preclinical studies using a prototype high-resolution PET system with Depth of Interaction , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[43]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.