Micro-Flow Visualization of Red Blood Cell-Enhanced Platelet Concentration at Sudden Expansion

Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a 100 μm:200 μm sudden expansion. Micro-flow visualization revealed a strong influence of hematocrit upon the path of RBCs and spatial concentration of particles. At all flow rates studied (Re = 8.3–41.7) and hematocrit 20% and lower, RBC streamlines were found to detach from the microchannel wall creating an RBC-depleted zone inside the step that was much larger than the cells themselves. However, the observed distribution of particles was relatively homogeneous. By contrast, the RBC streamlines of samples with hematocrit equal to or greater than 30% more closely followed the contour of the microchannel, yet exhibited enhanced concentration of particles within the corner. The corresponding size of the cell depletion layer was comparable with the size of the cells. This study implies that local platelet concentration in blood within the physiological range of hematocrit can be elevated within the flow separation region of a sudden expansion and implicates the role of RBCs in causing this effect.

[1]  David N. Ku,et al.  A Mechanistic Model of Acute Platelet Accumulation in Thrombogenic Stenoses , 2001, Annals of Biomedical Engineering.

[2]  Reto Schöb,et al.  Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device. , 2004, Artificial organs.

[3]  K. DenhamM,et al.  Laminar flow over a downstream-facing step in a two-dimensional flow channel. , 1974 .

[4]  I. Feuerstein,et al.  Platelet adhesion to fibrinogen-coated glass at an abrupt tubular expansion viewed with fluorescent video-microscopy. , 1986, Biorheology.

[5]  Kenneth A. Solen,et al.  Computational Model of Device-Induced Thrombosis and Thromboembolism , 2005, Annals of Biomedical Engineering.

[6]  N. Knezevic,et al.  Right atrial pacemaker lead thrombosis incidentally detected by transesophageal echocardiography. , 2005, Collegium Antropologicum.

[7]  Jan Vierendeels,et al.  Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model. , 2007, Journal of biomechanical engineering.

[8]  H. Goldsmith,et al.  Rheological Aspects of Thrombosis and Haemostasis: Basic Principles and Applications , 1986, Thrombosis and Haemostasis.

[9]  E. Eckstein,et al.  Model of platelet transport in flowing blood with drift and diffusion terms. , 1991, Biophysical journal.

[10]  K. Furie,et al.  Heart disease and stroke statistics--2007 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2008, Circulation.

[11]  R M Heethaar,et al.  Blood platelets are concentrated near the wall and red blood cells, in the center in flowing blood. , 1988, Arteriosclerosis.

[12]  G. Burgreen,et al.  A computational and experimental comparison of two outlet stators for the Nimbus LVAD. Left ventricular assist device. , 1999, ASAIO journal.

[13]  J. LaDisa,et al.  Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation , 2003, Annals of Biomedical Engineering.

[14]  Danny Bluestein,et al.  Flow-Induced Platelet Activation in Bileaflet and Monoleaflet Mechanical Heart Valves , 2004, Annals of Biomedical Engineering.

[15]  J. Antaki,et al.  Investigation of platelet margination phenomena at elevated shear stress. , 2007, Biorheology.

[16]  Fotis Sotiropoulos,et al.  Flow in a mechanical bileaflet heart valve at laminar and near-peak systole flow rates: CFD simulations and experiments. , 2005, Journal of biomechanical engineering.

[17]  G Rosenberg,et al.  Fluid dynamics of a pediatric ventricular assist device. , 2000, Artificial organs.

[18]  R. Heethaar,et al.  Red blood cell size is important for adherence of blood platelets to artery subendothelium , 1983 .

[19]  K. Furie,et al.  Heart disease and stroke statistics--2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2007, Circulation.

[20]  James F. Antaki,et al.  Simulation of platelet deposition in disturbed flow , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[21]  M. Sato,et al.  Hemodynamics at stenoses formed by growing platelet thrombi in mesenteric microvasculature of rat. , 1986, Microvascular research.

[22]  Danny Bluestein,et al.  Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. , 2007, Artificial organs.

[23]  H. Goldsmith,et al.  Aggregation of human platelets in an annular vortex distal to a tubular expansion. , 1979, Microvascular research.

[24]  John F LaDisa,et al.  Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery. , 2004, Journal of applied physiology.

[25]  T David,et al.  The effects of margination and red cell augmented platelet diffusivity on platelet adhesion in complex flow. , 2004, Biorheology.

[26]  James F. Antaki,et al.  A computational and experimental comparison of two outlet stators for the Nimbus LVAD , 1999 .

[27]  Chun Xu,et al.  Platelet near-wall excess in porcine whole blood in artery-sized tubes under steady and pulsatile flow conditions. , 2004, Biorheology.

[28]  Fotis Sotiropoulos,et al.  Numerical simulation of flow in mechanical heart valves: grid resolution and the assumption of flow symmetry. , 2003, Journal of biomechanical engineering.

[29]  Edward F. Leonard,et al.  Chapter 1 Principles of cardiovascular device design , 1993 .

[30]  H. Goldsmith,et al.  Adhesion of human platelets to collagen on the walls distal to a tubular expansion. , 1979, Microvascular research.

[31]  H. Goldsmith,et al.  Flow behaviour of blood cells and rigid spheres in an annular vortex. , 1977, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[32]  R. Heethaar,et al.  Red blood cell size is important for adherence of blood platelets to artery subendothelium. , 1983, Blood.

[33]  E. Bozkurt,et al.  Permanent pacemaker lead thrombosis leading to recurrent pulmonary embolism , 2006, Heart.

[34]  Roland Hetzer,et al.  Left ventricular assist device. , 2002, The New England journal of medicine.

[35]  T David,et al.  Platelet deposition in stagnation point flow: an analytical and computational simulation. , 2001, Medical engineering & physics.

[36]  Haiying Tang,et al.  Flow of a concentrated suspension through an abrupt axisymmetric expansion measured by nuclear magnetic resonance imaging , 2005 .

[37]  C. Zapanta,et al.  Multiscale Analysis of Surface Thrombosis In Vivo in a Left Ventricular Assist System , 2005, ASAIO journal.

[38]  Edward F. Leonard,et al.  Principles of Cardiovascular Device Design , 1993 .

[39]  S. Vallabhajosula,et al.  Dynamic monitoring of platelet deposition on severely damaged vessel wall in flowing blood. Effects of different stenoses on thrombus growth. , 1990, Arteriosclerosis.

[40]  B. Armaly,et al.  Experimental and theoretical investigation of backward-facing step flow , 1983, Journal of Fluid Mechanics.

[41]  C. Zapanta,et al.  Short-term In Vivo Studies of Surface Thrombosis in a Left Ventricular Assist System , 2006, ASAIO journal.

[42]  F. Millero,et al.  Conditions for the occurrence of large near-wall excesses of small particles during blood flow. , 1988, Microvascular research.

[43]  James F. Antaki,et al.  Computational Simulation of Platelet Deposition and Activation: I. Model Development and Properties , 1999, Annals of Biomedical Engineering.

[44]  H. Goldsmith The microrheology of human erythrocyte suspensions , 1973 .