Assessment of the densities of local anesthetics and their combination with adjuvants: an experimental study.

BACKGROUND AND OBJECTIVES The relative density of a local anesthetic in relation to that of the cerebrospinal fluid (CSF) at 37 degrees C is one of the most important physical properties that affect the level of analgesia obtained after the subarachnoid administration of the drug. The objective of this study was to determine the density of local anesthetic solutions, with and without glucose, and the combination of the local anesthetic with adjuvants at 20 degrees C, 25 degrees C, and 37 degrees C. METHODS The density (g.mL(-1)) was determined by using a DMA 450 densimeter with a sensitivity of +/- 0.00001 g.mL(-1). The densities, and variations, according to the temperature were obtained for all local anesthetics and their combination with opioids at 20 degrees C, 25 degrees C, and 37 degrees C. The solution is hyperbaric if its density exceeds 1.00099, hypobaric when its density is lower than 1.00019, and isobaric when its density is greater than 1.00019 and lower than 1.00099. RESULTS The densities of both local anesthetics and adjuvants decrease with the increase in temperature. At 37 degrees C, all glucose-containing solutions are hyperbaric. In the absence of glucose, all solutions are hypobaric. At 37 degrees C, morphine, fentanyl, sufentanil, and clonidine are hypobaric. CONCLUSIONS The densities of local anesthetics and adjuvants decrease with the increase in temperature and increase when glucose is added. The knowledge of the relative density helps select the most adequate local anesthetic to be administered in the subarachnoid space.

[1]  R. Fernando,et al.  Predicting the density of bupivacaine and bupivacaine-opioid combinations. , 2002, Anesthesia and analgesia.

[2]  J. Parlow,et al.  The addition of fentanyl does not alter the extent of spread of intrathecal isobaric bupivacaine in clinical practice , 2001, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[3]  A. Lui,et al.  Densities of cerebrospinal fluid and spinal anaesthetic solutions in surgical patients at body temperature , 1998, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[4]  M. Richardson,et al.  Densities of Dextrose-Free Intrathecal Local Anesthetics, Opioids, and Combinations Measured at 37 degrees C , 1997, Anesthesia and analgesia.

[5]  T. Horlocker,et al.  Density, specific gravity, and baricity of spinal anesthetic solutions at body temperature. , 1993, Anesthesia and analgesia.

[6]  N. M. Greene,et al.  Factors Affecting the Subarachnoid Spread of Local Anesthetic Solutions , 1991, Regional Anesthesia & Pain Medicine.

[7]  M. Gielen,et al.  The Influence of Temperature and Speed of Injection on the Distribution of a Solution Containing Bupivacaine and Methylene Blue in a Spinal Canal Model , 1990, Regional Anesthesia & Pain Medicine.

[8]  N. M. Greene Distribution of Local Anesthetic Solutions within the Subarachnoid Space , 1985, Anesthesia and analgesia.

[9]  S. Muravchick,et al.  Density of Normal Human Cerebrospinal Fluid and Tetracaine Solutions , 1981, Anesthesia and analgesia.

[10]  H. Davis,et al.  DENSITIES OF CEREBROSPINAL FLUID OF HUMAN BEINGS , 1954, Anesthesiology.

[11]  J. Parlow,et al.  Addition of opioids alters the density and spread of intrathecal local anesthetics? Anin vitro study , 1999, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[12]  A. Holdcroft,et al.  Density of intrathecal agents. , 1992, British journal of anaesthesia.