A Dual Transducer Ultrasound System for Quantitative Doppler Measurements

The possibility of accurately measuring the velocity of blood flowing in human vessels represents a significant opportunity for hemodynamic research and diagnosis. The ultrasound (US) investigation represents a non invasive, diffuse and low cost method capable of evaluating the blood velocity by exploiting the Doppler effect. Unfortunately, the accuracy attainable with standard US equipment is heavily limited by the difficulty of assessing the Doppler angle during in-vivo investigations. In this paper a house-made US system for quantitative velocity measurements is presented. This system relies on an open, full digital architecture appositely designed for research purposes. In particular, the system capability of simultaneously controlling two US probes is shown suitable to implement a novel measurement method which overcomes the above Doppler angle ambiguity. The results of recent in-vitro experiments are reported, showing a velocity measurement accuracy of 0.5% and a precision of 7%.

[1]  P. Tortoli,et al.  Method for Microbubble Characterization Using Primary Radiation Force , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  P Tortoli,et al.  A novel ultrasound instrument for investigation of arterial mechanics. , 2004, Ultrasonics.

[3]  R. Reneman,et al.  A radio frequency domain complex cross-correlation model to estimate blood flow velocity and tissue motion by means of ultrasound. , 1997, Ultrasound in medicine & biology.

[4]  D. Friedman,et al.  Umbilical artery Doppler blood velocity waveforms in normal and abnormal gestations. , 1989, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[5]  R. Y. Chiao,et al.  Coded excitation for diagnostic ultrasound: a system developer's perspective , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  J M Wardlaw,et al.  Variability in Doppler ultrasound influences referral of patients for carotid surgery. , 2000, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[7]  V. L. Newhouse,et al.  Theory of Ultrasound Doppler-Spectra Velocimetry for Arbitrary Beam and Flow Configurations , 1986, IEEE 1986 Ultrasonics Symposium.

[8]  F. Duck Nonlinear acoustics in diagnostic ultrasound. , 2002, Ultrasound in medicine & biology.

[9]  Piero Tortoli,et al.  Interaction between secondary velocities, flow pulsation and vessel morphology in the common carotid artery. , 2003, Ultrasound in medicine & biology.

[10]  Ray Andraka,et al.  Digital Radio High Performance Digital Down-Converters for FPGAs , 2001 .

[11]  V. Newhouse,et al.  Ultrasound Doppler Probing of Flows Transverse with Respect to Beam Axis , 1987, IEEE Transactions on Biomedical Engineering.

[12]  K J Parker,et al.  Contrast agents in diagnostic ultrasound. , 1990, Ultrasound in medicine & biology.

[13]  Joanna M Wardlaw,et al.  Which Doppler velocity is best for assessing suitability for carotid endarterectomy? , 2002, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[14]  P. Tortoli,et al.  Accurate Doppler angle estimation for vector flow measurements , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Piero Tortoli,et al.  Introduction to the Special Issue on Novel Equipment for Ultrasound Research , 2006 .

[16]  C. Atzeni,et al.  A review of experimental transverse Doppler studies , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  W H Baker,et al.  An approach for the use of Doppler ultrasound as a screening tool for hemodynamically significant stenosis (despite heterogeneity of Doppler performance). A multicenter experience. Asymptomatic Carotid Atherosclerosis Study Investigators. , 1996, Stroke.