Auditory displays in anesthesiology

Purpose of review We outline and discuss recent work on auditory displays, covering both auditory alarms that indicate technical or physiological threshold levels and informative auditory displays that provide a continuous awareness of a patient's well being. Recent findings The struggle to make auditory alarms informative proceeds with work on two fronts. In one approach, researchers are developing and evaluating auditory alarm displays to indicate the source and urgency of off-normal states and are relying on the emergence of smart software algorithms to reduce the false-positive rate. In a complementary approach, other researchers are providing information about the patient's well being in normal as well as abnormal states, generalizing the advantages of variable-tone pulse oximetry to other systems and other auditory display formats. In either approach, a multidisciplinary team is essential in the design and evaluation of auditory displays. Because informative auditory displays may subtly change clinical practice, there are repercussions for training. Summary Auditory display in anesthesia can extend well beyond auditory alarms to displays that give the anesthesiologist a continuous peripheral awareness of patient well being. Much more rigorous approaches should be taken to evaluating auditory displays so they add information rather than noise.

[1]  Kerstin Persson Waye,et al.  Characterizing noise and perceived work environment in a neurological intensive care unit. , 2008, The Journal of the Acoustical Society of America.

[2]  Marcus Watson,et al.  Earcon for intermittent information in monitoring environments , 2004 .

[3]  Penelope M. Sanderson,et al.  Ecological Interface Design for Pasteurizer II: A Process Description of Semantic Mapping , 2002, Hum. Factors.

[4]  John Usher,et al.  Audio spectrum and sound pressure levels vary between pulse oximeters , 2006, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[5]  Roland Fried,et al.  The crying wolf: still crying? , 2009, Anesthesia and analgesia.

[6]  Paul Barach,et al.  A New Paradigm for the Design of Audible Alarms that Convey Urgency Information , 2007, Journal of Clinical Monitoring and Computing.

[7]  P. M. Sanderson,et al.  The effects of ambient music on simulated anaesthesia monitoring , 2005, Anaesthesia.

[8]  Penelope M. Sanderson,et al.  Overlapping Melodic Alarms Are Almost Indiscriminable , 2007, Hum. Factors.

[9]  A F Merry,et al.  A New, Safety-Oriented, Integrated Drug Administration and Automated Anesthesia Record System , 2001, Anesthesia and analgesia.

[10]  Marcus Watson,et al.  Sonification Supports Eyes-Free Respiratory Monitoring and Task Time-Sharing , 2004, Hum. Factors.

[11]  Stephen Brewster,et al.  A Detailed Investigation into the Effectiveness of Earcons , 1997 .

[12]  Penelope M. Sanderson,et al.  Multisensory Integration with a Head-Mounted Display: Sound Delivery and Self-Motion , 2008, Hum. Factors.

[13]  R. Hagenouw,et al.  Should we be alarmed by our alarms? , 2007, Current opinion in anaesthesiology.

[14]  M. Imhoff,et al.  Alarm Algorithms in Critical Care Monitoring , 2006, Anesthesia and analgesia.

[15]  Takeshi Akita,et al.  The Sound Intensity and Characteristics of Variable-pitch Pulse Oximeters , 2008, Journal of Clinical Monitoring and Computing.

[16]  P. D. Wheeler,et al.  Alarm sounds for medical equipment in intensive care areas and operating theatres , 1981 .

[17]  Gregory Kramer,et al.  An introduction to auditory display , 1994 .

[18]  Marcus Watson,et al.  Designing for Attention With Sound: Challenges and Extensions to Ecological Interface Design , 2007, Hum. Factors.

[19]  Penelope M Sanderson,et al.  Are Melodic Medical Equipment Alarms Easily Learned? , 2008, Anesthesia and analgesia.

[20]  Matthias Görges,et al.  Improving Alarm Performance in the Medical Intensive Care Unit Using Delays and Clinical Context , 2009, Anesthesia and analgesia.

[21]  Stephen Barrass,et al.  Listening to the Mind Listening: An Analysis of Sonification Reviews, Designs and Correspondences , 2006, Leonardo Music Journal.

[22]  Sidney Fels,et al.  An Evaluation of a Vibro-Tactile Display Prototype for Physiological Monitoring , 2005, Anesthesia and analgesia.

[23]  P M Sanderson,et al.  Learnability and discriminability of melodic medical equipment alarms * , 2006, Anaesthesia.

[24]  Penelope M. Sanderson,et al.  Overlapping medical alarms are almost indiscriminable , 2007 .

[25]  Robert G Loeb,et al.  A laboratory evaluation of an auditory display designed to enhance intraoperative monitoring. , 2002, Anesthesia and analgesia.

[26]  Thomas G. Cleaver,et al.  The Sounds of Saturation , 2004, Journal of Clinical Monitoring and Computing.

[27]  Penelope M. Sanderson,et al.  Auditory alarms, medical standards, and urgency , 2006 .

[28]  W. Karwowski International encyclopedia of ergonomics and human factors , 2001 .

[29]  Frank E. Block,et al.  A Proposed New Set of Alarm Sounds which Satisfy Standards and Rationale to Encode Source Information , 2004, Journal of Clinical Monitoring and Computing.

[30]  Penelope Sanderson,et al.  Sonification design for complex work domains: dimensions and distractors. , 2009, Journal of experimental psychology. Applied.

[31]  J P Bliss,et al.  Human probability matching behaviour in response to alarms of varying reliability. , 1995, Ergonomics.

[32]  Gerold Baier,et al.  Event-based sonification of EEG rhythms in real time , 2007, Clinical Neurophysiology.

[33]  Penelope Sanderson,et al.  The multimodal world of medical monitoring displays. , 2006, Applied ergonomics.

[34]  Gasthurie Kanagachandran,et al.  Pilot study: Designing Medical Alarm Sounds For Semantic Association And Ease Of Learning , 2006 .

[35]  Stephen A. Brewster,et al.  Understanding concurrent earcons: Applying auditory scene analysis principles to concurrent earcon recognition , 2004, TAP.

[36]  R W Morris,et al.  How Well Can Anaesthetists Discriminate Pulse Oximeter Tones? , 2005, Anaesthesia and intensive care.

[37]  J M Ansermino,et al.  Clinical evaluation of algorithms for context-sensitive physiological monitoring in children. , 2009, British journal of anaesthesia.

[38]  Sylvie Charbonnier,et al.  A trend-based alarm system to improve patient monitoring in intensive care units , 2007 .

[39]  J Mark Ansermino,et al.  A Novel Vibrotactile Display to Improve the Performance of Anesthesiologists in a Simulated Critical Incident , 2008, Anesthesia and analgesia.

[40]  Bruce N. Walker,et al.  Consistency of magnitude estimations with conceptual data dimensions used for sonification , 2007 .

[41]  Nadine Sarter,et al.  Multimodal information presentation: Design guidance and research challenges , 2006 .

[42]  Neville Stanton Speech-based alarm displays , 1993 .

[43]  Alexandre Alapetite Impact of noise and other factors on speech recognition in anaesthesia , 2008, Int. J. Medical Informatics.

[44]  Penelope M. Sanderson,et al.  Anesthesia Alarms in Context: An Observational Study , 2001, Hum. Factors.

[45]  Marcus Watson,et al.  Tailoring reveals information requirements: the case of anaesthesia alarms , 2004, Interact. Comput..

[46]  K B Bennett,et al.  Graphical Displays: Implications for Divided Attention, Focused Attention, and Problem Solving , 1992, Human factors.

[47]  Meera Blattner,et al.  Earcons and Icons: Their Structure and Common Design Principles , 1989, Hum. Comput. Interact..

[48]  P. Beatty,et al.  Establishing scales of perceived severity for clinical situations during anaesthesia. , 2005, British journal of anaesthesia.

[49]  Theophanis Katostaras,et al.  Noise in the operating rooms of Greek hospitals. , 2008, The Journal of the Acoustical Society of America.

[50]  Guy A Dumont,et al.  An Evaluation of a Novel Software Tool for Detecting Changes in Physiological Monitoring , 2009, Anesthesia and analgesia.

[51]  A. Furnham,et al.  Music is as distracting as noise: the differential distraction of background music and noise on the cognitive test performance of introverts and extraverts , 2002, Ergonomics.

[52]  Rebecca Randell Accountability in an alarming environment , 2004, CSCW.

[53]  Marcus Watson Scalable earcons: Bridging the gap between intermittent and continuous auditory displays , 2006 .

[54]  Alexandre Alapetite Speech recognition for the anaesthesia record during crisis scenarios , 2008, Int. J. Medical Informatics.

[55]  Penelope M Sanderson,et al.  Advanced Auditory Displays and Head-Mounted Displays: Advantages and Disadvantages for Monitoring by the Distracted Anesthesiologist , 2008, Anesthesia and analgesia.

[56]  K McGookinDavid,et al.  Understanding concurrent earcons , 2004 .

[57]  Marcus Watson,et al.  Extending Ecological Interface Design to Auditory Displays , 2000 .

[58]  Sarah Williams,et al.  Measuring the performance of audible alarms for anaesthesia , 2005, Physiological measurement.

[59]  David Woods,et al.  The alarm problem and directed attention in dynamic fault management , 1995 .

[60]  Frank E Block,et al.  "For if the trumpet give an uncertain sound, who shall prepare himself to the battle?" (I Corinthians 14:8, KJV). , 2008, Anesthesia and analgesia.

[61]  Ursula Gather,et al.  Smart alarms from medical devices in the OR and ICU. , 2009, Best practice & research. Clinical anaesthesiology.

[62]  Vincent Dousset,et al.  Audibility of anaesthesia alarms during magnetic resonance imaging: should we be alarmed? , 2009, European journal of anaesthesiology.

[63]  Christopher D. Wickens,et al.  When is Less More? Attention and Workload in Auditory, Visual, and Redundant Patient-Monitoring Conditions , 2001 .