Research on voltage optimization for SRG wind power system

Actual characteristics of Switched Reluctance Generator (SRG) are simply introduced. A novel voltage optimization strategy of combining classical feedback control with excitation angles position control (APC) is proposed considering special work conditions and the application is analyzed in detail. Simulation results show that the voltage optimization can be realized with developed regulation system on the basis of fuzzy logic scheme and excellent electrical energy quality can be sent out with smooth amplitude, rapid response, and low harmonic content.

[1]  Dong-Seok Hyun,et al.  An Improved Carrier-Based SVPWM Method Using Leg Voltage Redundancies in Generalized Cascaded , 2003 .

[2]  Christos Mademlis,et al.  Optimal efficiency control of switched reluctance generators , 2006, IEEE Transactions on Power Electronics.

[3]  Ahmet M. Hava,et al.  Carrier-based PWM-VSI overmodulation strategies: analysis, comparison, and design , 1998 .

[4]  A. Piccolo,et al.  Designing an Adaptive Fuzzy Controller for Maximum Wind Energy Extraction , 2008, IEEE Transactions on Energy Conversion.

[5]  Dong-Choon Lee,et al.  A novel overmodulation technique for space vector PWM inverters , 1997 .

[6]  B. Fahimi,et al.  Design and control characterization of switched reluctance generator for maximum output power , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[7]  David A. Torrey Variable-reluctance generators in wind-energy systems , 1993, Proceedings of IEEE Power Electronics Specialist Conference - PESC '93.

[8]  Y. Sozer,et al.  Closed loop control of excitation parameters for high speed switched-reluctance generators , 2003, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[9]  Chang-Ming Liaw,et al.  On the Design of Power Circuit and Control Scheme for Switched Reluctance Generator , 2008, IEEE Transactions on Power Electronics.

[10]  J. Clare,et al.  Control of a switched reluctance generator for variable-speed wind energy applications , 2005, IEEE Transactions on Energy Conversion.

[11]  Walter Issamu Suemitsu,et al.  Fuzzy logic torque ripple reduction by turn-off angle compensation for switched reluctance motors , 2001, IEEE Trans. Ind. Electron..

[12]  B. Fahimi,et al.  A switched reluctance machine-based starter/alternator for more electric cars , 2001, IEEE Transactions on Energy Conversion.

[13]  Ali Emadi,et al.  A switched reluctance machine-based starter/alternator for more electric cars , 2004 .

[14]  Wen Xuhui,et al.  Math Demonstration and Practical Application of Fundamental Voltage Amplitude Linear Output Based SVPWM Overmodulation Control , 2006, Conference Record of the 2006 IEEE Industry Applications Conference Forty-First IAS Annual Meeting.

[15]  R. S. Kanchan,et al.  Space vector PWM signal generation for multilevel inverters using only the sampled amplitudes of reference phase voltages , 2005 .