Conducting Polymer Scaffolds for Hosting and Monitoring 3D Cell Culture

This work reports the design of a live‐cell monitoring platform based on a macroporous scaffold of a conducting polymer, poly(3,4‐ethylene dioxythiophene):poly(styrenesulfonate). The conducting polymer scaffolds support 3D cell cultures due to their biocompatibility and tissue‐like elasticity, which can be manipulated by inclusion of biopolymers such as collagen. Integration of a media perfusion tube inside the scaffold enables homogenous cell spreading and fluid transport throughout the scaffold, ensuring long term cell viability. This also allows for co‐culture of multiple cell types inside the scaffold. The inclusion of cells within the porous architecture affects the impedance of the electrically conducting polymer network and, thus, is utilized as an in situ tool to monitor cell growth. Therefore, while being an integral part of the 3D tissue, the conducting polymer is an active component, enhancing the tissue function, and forming the basis for a bioelectronic device with integrated sensing capability.

[1]  C. Lo,et al.  Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing. , 1995, Biophysical journal.

[2]  M J Bissell,et al.  Influence of a reconstituted basement membrane and its components on casein gene expression and secretion in mouse mammary epithelial cells. , 1987, Proceedings of the National Academy of Sciences of the United States of America.

[3]  Stephen A Boppart,et al.  Imaging and analysis of three-dimensional cell culture models. , 2010, Methods in molecular biology.

[4]  Ronan M. T. Fleming,et al.  Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices. , 2015, Biosensors & bioelectronics.

[5]  S. Löffler,et al.  Phase angle spectroscopy on transparent conducting polymer electrodes for real-time measurement of epithelial barrier integrity. , 2015, Journal of materials chemistry. B.

[6]  T. Slaga,et al.  Amended Safety Assessment of Dodecylbenzenesulfonate, Decylbenzenesulfonate, and Tridecylbenzenesulfonate Salts as Used in Cosmetics , 2010, International journal of toxicology.

[7]  Jonathan Rivnay,et al.  Monitoring of cell layer coverage and differentiation with the organic electrochemical transistor. , 2015, Journal of materials chemistry. B.

[8]  P. Leleux,et al.  In vivo recordings of brain activity using organic transistors , 2013, Nature Communications.

[9]  Jonathan Rivnay,et al.  Combined Optical and Electronic Sensing of Epithelial Cells Using Planar Organic Transistors , 2014, Advanced materials.

[10]  D. Cumming,et al.  Development of a conducting polymer cell impedance sensor , 2013 .

[11]  Laura Ylä-Outinen,et al.  Three‐dimensional growth matrix for human embryonic stem cell‐derived neuronal cells , 2014, Journal of tissue engineering and regenerative medicine.

[12]  R. Kamm,et al.  Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels , 2012, Nature Protocols.

[13]  Tien Anh Nguyen,et al.  Microfluidic chip with integrated electrical cell-impedance sensing for monitoring single cancer cell migration in three-dimensional matrixes. , 2013, Analytical chemistry.

[14]  G. Malliaras,et al.  Electroconductive Hydrogel Based on Functional Poly(Ethylenedioxy Thiophene) , 2016, Chemistry of materials : a publication of the American Chemical Society.

[15]  Shiming Zhang,et al.  Solvent-induced changes in PEDOT:PSS films for organic electrochemical transistors , 2015 .

[16]  M J Bissell,et al.  Extracellular matrix-dependent tissue-specific gene expression in mammary epithelial cells requires both physical and biochemical signal transduction. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[17]  P. Janmey,et al.  Tissue Cells Feel and Respond to the Stiffness of Their Substrate , 2005, Science.

[18]  Zhangqi Feng,et al.  Three-Dimensional BC/PEDOT Composite Nanofibers with High Performance for Electrode-Cell Interface. , 2015, ACS applied materials & interfaces.

[19]  Matsuhiko Nishizawa,et al.  Highly Conductive Stretchable and Biocompatible Electrode–Hydrogel Hybrids for Advanced Tissue Engineering , 2014, Advanced healthcare materials.

[20]  L. H. Jimison,et al.  Validation of the organic electrochemical transistor for in vitro toxicology. , 2013, Biochimica et biophysica acta.

[21]  P. Wertz,et al.  The human epidermis models EpiSkin, SkinEthic and EpiDerm: an evaluation of morphology and their suitability for testing phototoxicity, irritancy, corrosivity, and substance transport. , 2005, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[22]  M. Spira,et al.  Multi-electrode array technologies for neuroscience and cardiology. , 2013, Nature nanotechnology.

[23]  Andreas Offenhäusser,et al.  Membrane on a chip: a functional tethered lipid bilayer membrane on silicon oxide surfaces. , 2005, Biophysical journal.

[24]  G. Lajoie,et al.  Matrigel: A complex protein mixture required for optimal growth of cell culture , 2010, Proteomics.

[25]  Mandy B. Esch,et al.  Modular, pumpless body-on-a-chip platform for the co-culture of GI tract epithelium and 3D primary liver tissue. , 2016, Lab on a chip.

[26]  Jonathan Rivnay,et al.  Organic electrochemical transistors for cell-based impedance sensing , 2015 .

[27]  H. Lilie,et al.  Comparative label-free monitoring of immunotoxin efficacy in 2D and 3D mamma carcinoma in vitro models by impedance spectroscopy. , 2014, Biosensors & bioelectronics.

[28]  Stefan Aigner,et al.  Multicellular Self-Assembled Spheroidal Model of the Blood Brain Barrier , 2013, Scientific Reports.

[29]  J. Wegener,et al.  Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces. , 2000, Experimental cell research.

[30]  George G. Malliaras,et al.  The Rise of Organic Bioelectronics , 2014 .

[31]  M. Ramuz,et al.  Research Update: Electrical monitoring of cysts using organic electrochemical transistors a , 2015 .

[32]  Gordon G Wallace,et al.  Correlation of the impedance and effective electrode area of doped PEDOT modified electrodes for brain-machine interfaces. , 2015, The Analyst.

[33]  G. Malliaras,et al.  A physical interpretation of impedance at conducting polymer/electrolyte junctions , 2014 .

[34]  Michael Fischer,et al.  Microcavity array (MCA)-based biosensor chip for functional drug screening of 3D tissue models. , 2008, Biosensors & bioelectronics.

[35]  Min Zhao,et al.  Controlling cell behavior electrically: current views and future potential. , 2005, Physiological reviews.

[36]  Andrew J. Ewald,et al.  Three-dimensional organotypic culture: experimental models of mammalian biology and disease , 2014, Nature Reviews Molecular Cell Biology.

[37]  J. Hetke,et al.  Surface modification of neural recording electrodes with conducting polymer/biomolecule blends. , 2001, Journal of biomedical materials research.

[38]  Sun‐mi Lee,et al.  Real-time monitoring of 3D cell culture using a 3D capacitance biosensor. , 2016, Biosensors & bioelectronics.

[39]  Michael Fischer,et al.  Drug testing on 3D in vitro tissues trapped on a microcavity chip. , 2008, Lab on a chip.

[40]  A. Srivastava,et al.  Bio-functionalized Pt nanoparticles based electrochemical impedance immunosensor for human cardiac myoglobin , 2014 .

[41]  Ivar Giaever,et al.  A morphological biosensor for mammalian cells , 1993, Nature.

[42]  Shu-Ping Lin,et al.  On-line observation of cell growth in a three-dimensional matrix on surface-modified microelectrode arrays. , 2009, Biomaterials.

[43]  Gordon G Wallace,et al.  Skeletal muscle cell proliferation and differentiation on polypyrrole substrates doped with extracellular matrix components. , 2009, Biomaterials.

[44]  Donald E. Ingber,et al.  Distinct Contributions of Astrocytes and Pericytes to Neuroinflammation Identified in a 3D Human Blood-Brain Barrier on a Chip , 2016, PloS one.

[45]  S. Sen,et al.  Matrix Elasticity Directs Stem Cell Lineage Specification , 2006, Cell.

[46]  Majid Ebrahimi Warkiani,et al.  Flow-induced stress on adherent cells in microfluidic devices. , 2015, Lab on a chip.

[47]  Kin Fong Lei,et al.  Impedimetric quantification of the formation process and the chemosensitivity of cancer cell colonies suspended in 3D environment. , 2015, Biosensors & bioelectronics.

[48]  Jennifer Barrila,et al.  Organotypic 3D cell culture models: using the rotating wall vessel to study host–pathogen interactions , 2010, Nature Reviews Microbiology.

[49]  Brendon M. Baker,et al.  Deconstructing the third dimension – how 3D culture microenvironments alter cellular cues , 2012, Journal of Cell Science.

[50]  Sahika Inal,et al.  3D Conducting Polymer Platforms for Electrical Control of Protein Conformation and Cellular Functions. , 2015, Journal of materials chemistry. B.

[51]  Joachim Wegener,et al.  Bioelectrical impedance assay to monitor changes in cell shape during apoptosis. , 2004, Biosensors & bioelectronics.

[52]  I. Giaever,et al.  Monitoring fibroblast behavior in tissue culture with an applied electric field. , 1984, Proceedings of the National Academy of Sciences of the United States of America.

[53]  P. Fromherz,et al.  A neuron-silicon junction: a Retzius cell of the leech on an insulated-gate field-effect transistor. , 1991, Science.

[54]  R Langer,et al.  Stimulation of neurite outgrowth using an electrically conducting polymer. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[55]  Christophe Bernard,et al.  Bioelectronic neural pixel: Chemical stimulation and electrical sensing at the same site , 2016, Proceedings of the National Academy of Sciences.

[56]  David C. Martin,et al.  Electrochemical deposition and characterization of carboxylic acid functionalized PEDOT copolymers , 2014 .