Development of a Continuous-Flow Hydride and Mercury Vapor Generation Accessory for Atomic Absorption Spectrophotometry

The design and performance characteristics of a continuous-flow vapor generation accessory for atomic absorption spectrophotometry are reported. When used with a conventional atomic absorption spectrophotometer, the accessory provides analytical sensitivity for mercury, arsenic, selenium, antimony, bismuth, tellurium, and tin equal or superior to that of a batch-type vapor generation device. Sample presentation, sample consumption, precision of measurement, and simplicity of operation are similar to those of flame atomic absorption with a pneumatic nebulizer. Details of the construction of the continuous-flow manifold, gas/liquid separator, and absorption cells are discussed, and the effects of reagent concentrations and carrier gas flow rates are shown. Characteristic concentrations and analytical curves for the above elements are also presented.

[1]  T. Nakahara The Determination of Trace Amounts of Tin by Inductively Coupled Argon Plasma Atomic Emission Spectrometry with Volatile Hydride Method , 1983 .

[2]  Yongming Liu,et al.  DEVELOPMENT AND PERFORMANCE 0F AN AUT0MATIC HYDRIDE/MERCURY SYSTEM , 1983 .

[3]  B. Welz,et al.  Investigations on atomisation mechanisms of volatile hydride-forming elements in a heated quartz cell. Part 1. Gas-phase and surface effects; decomposition and atomisation of arsine , 1983 .

[4]  M. Taga,et al.  Determination of lead by continuous-flow hydride generation and atomic absorption spectrometry , 1982 .

[5]  W. Maher MEASUREMENT OF TOTAL TIN IN MARINE ORGANISMS BY STANNANE GENERATION AND ATOMIC ABSORPTION SPECTROMETRY , 1982 .

[6]  Ove. Aastroem Flow injection analysis for the determination of bismuth by atomic absorption spectrometry with hydride generation , 1982 .

[7]  L. Ebdon,et al.  A simple and sensitive continuous hydride generation system for the determination of arsenic and selenium by atomic absorption and atomic fluorescence spectrometry , 1982 .

[8]  J. Ingle,et al.  Continuous flow cold vapor atomic absorption determination of mercury , 1981 .

[9]  P. D. Goulden,et al.  Determination of arsenic and selenium in water, fish, and sediments by inductively coupled argon plasma emission spectrometry. , 1981, Analytical chemistry.

[10]  S. Hamada,et al.  Determination of lead at the ng ml-1 level by reduction to plumbane and measurement by inductively-coupled plasma emission spectrometry , 1981 .

[11]  P. Coyle,et al.  Automated determination of mercury in urine and blood by the Magos reagent and cold vapor atomic absorption spectrometry. , 1981, Analytical chemistry.

[12]  J. Dědina,et al.  Hydride atomization in a cool hydrogen—oxygen flame burning in a quartz tube atomizer , 1980 .

[13]  W. Evans,et al.  Evaluation of a method for determination of total antimony, arsenic and tin in foodstuffs using measurement by atomic-absorption spectrophotometry with atomisation in a silica tube using the hydride generation technique. , 1979, The Analyst.

[14]  B. Pahlavanpour,et al.  Simultaneous determination of trace concentrations of arsenic, antimony, bismuth, selenium and tellurium in aqueous solution by introduction of the gaseous hydrides into an inductively coupled plasma source for emission spectrometry. Part I. Preliminary studies , 1978 .

[15]  Chris C. Y. Chan,et al.  Determination of tin by gas phase atomization and atomic absorption spectrometry , 1976 .

[16]  L. Snyder,et al.  Automated chemical analysis: update on continuous-flow approach , 1976 .

[17]  H. R. Brown,et al.  Inorganic interference study of automated arsenic and selenium determination with atomic absorption spectrometry , 1976 .

[18]  A. C. Rayner,et al.  A semi-automated method for the determination of arsenic in soil and vegetation by gas-phase sampling and atomic absorption spectrometry. , 1976, Analytica chimica acta.

[19]  G. R. Wood,et al.  An automated submicrogram determination of selenium in vegetation by quartz-tube furnace atomic-absorption spectrophotometry. , 1976, Talanta.

[20]  R. S. Fraser,et al.  An Automated Technique for the Sub-Microgram Determination of Selenium and Arsenic in Surface Waters by Atomic Absorption Spectroscopy , 1976 .

[21]  R. C. Rooney,et al.  Use of sodium borohydride for cold-vapour atomic-absorption determination of trace amounts of inorganic mercury , 1976 .

[22]  J Savory,et al.  Use of sodium borohydride for determination of total mercury in urine by atomic absorption spectrometry. , 1975, Analytical chemistry.

[23]  A M Ure,et al.  The determination of mercury by non-flame atomic absorption and fluorescence spectrometry. , 1975, Analytica chimica acta.

[24]  F. J. Schmidt,et al.  Automated Determination of Arsenic, Selenium, Antimony, Bismuth and Tin by Atomic Absorption Utilizing Sodium Borohydride Reduction , 1975 .

[25]  J. Ingle Precision of atomic absorption spectrometric measurements , 1974 .

[26]  P. D. Goulden,et al.  Automated atomic absorption determination of arsenic, antimony, and selenium in natural waters. , 1974, Analytical chemistry.

[27]  Cyrus Feldman,et al.  Preservation of dilute mercury solutions , 1974 .

[28]  K. Kan An Automated Method for the Determination of Arsenic and Antimony , 1973 .

[29]  F. Lo,et al.  Automated method for determination of mercury. , 1971, Analytical chemistry.

[30]  M. Stainton,et al.  Syringe procedure for transfer of nanogram quantities of mercury vapor for flameless atomic absorption spectrophotometry , 1971 .