Clinical efficacy of early loading versus conventional loading of dental implants

[1]  M. Sanz,et al.  Clinical efficacy of immediate implant loading protocols compared to conventional loading depending on the type of the restoration: a systematic review. , 2015, Clinical oral implants research.

[2]  Yufeng Zhang,et al.  Comparison of implant success rates with different loading protocols: a meta-analysis. , 2014, The International journal of oral & maxillofacial implants.

[3]  Gary L. Stafford Different loading times for dental implants – no clinically important differences? , 2013, Evidence-Based Dentistry.

[4]  Hai-Yang Yu,et al.  Micromotions and combined damages at the dental implant/bone interface , 2012, International Journal of Oral Science.

[5]  R. Barewal,et al.  A randomized controlled clinical trial comparing the effects of three loading protocols on dental implant stability. , 2012, The International journal of oral & maxillofacial implants.

[6]  I. Turkyilmaz,et al.  Seven-year follow-up results of TiUnite implants supporting mandibular overdentures: early versus delayed loading. , 2012, Clinical implant dentistry and related research.

[7]  H. Sandhu,et al.  Clinical Evaluation of Early Loaded and Unloaded Implants in Edentulous Mandible , 2012, Journal of Maxillofacial and Oral Surgery.

[8]  Dastur Fd,et al.  Mandibular overdentures with immediate loading: satisfaction and quality of life. , 2011 .

[9]  D. E. Slot,et al.  Effect of socket preservation therapies following tooth extraction in non-molar regions in humans: a systematic review. , 2011, Clinical oral implants research.

[10]  A. Thor,et al.  Patient satisfaction following dental implant treatment with immediate loading in the edentulous atrophic maxilla. , 2011, The International journal of oral & maxillofacial implants.

[11]  F. D. das Neves,et al.  Mandibular overdentures with immediate loading: satisfaction and quality of life. , 2011, The International journal of prosthodontics.

[12]  W. Thomson,et al.  Marginal bone loss with mandibular two-implant overdentures using different loading protocols and attachment systems: 10-year outcomes. , 2010, The International journal of prosthodontics.

[13]  I. Turkyilmaz,et al.  Early versus delayed loading of mandibular implant-supported overdentures: 5-year results. , 2009, Clinical implant dentistry and related research.

[14]  M. Atieh,et al.  Loading protocols for mandibular implant overdentures: a systematic review with meta-analysis. , 2009, Clinical implant dentistry and related research.

[15]  M. Esposito,et al.  A 5-year report from a multicentre randomised clinical trial: immediate non-occlusal versus early loading of dental implants in partially edentulous patients. , 2010, European journal of oral implantology.

[16]  A. Wennerberg,et al.  A retrospective analysis of early and delayed loading of full-arch mandibular prostheses using three different implant systems: clinical results with up to 5 years of loading. , 2009, Clinical implant dentistry and related research.

[17]  David J Spiegelhalter,et al.  A re-evaluation of random-effects meta-analysis , 2009, Journal of the Royal Statistical Society. Series A,.

[18]  A. Eliasson On the role of number of fixtures, surgical technique and timing of loading. , 2008, Swedish dental journal. Supplement.

[19]  L. Sennerby,et al.  Five-year results from a randomized, controlled trial on early and delayed loading of implants supporting full-arch prosthesis in the edentulous maxilla. , 2008, Clinical oral implants research.

[20]  I. Turkyilmaz,et al.  A 4-year prospective clinical and radiological study of maxillary dental implants supporting single-tooth crowns using early and delayed loading protocols. , 2007, Clinical implant dentistry and related research.

[21]  I. Turkyilmaz,et al.  Early versus late loading of unsplinted TiUnite surface implants supporting mandibular overdentures: a 2-year report from a prospective study. , 2007, Journal of oral rehabilitation.

[22]  R. Jacobs,et al.  Timing of loading--immediate, early, or delayed--in the outcome of implants in the edentulous mandible: a prospective clinical trial. , 2007, The International journal of oral & maxillofacial implants.

[23]  H V Worthington,et al.  Interventions for replacing missing teeth: different times for loading dental implants. , 2013, The Cochrane database of systematic reviews.

[24]  I. Turkyilmaz,et al.  A 2-year clinical report of patients treated with two loading protocols for mandibular overdentures: early versus conventional loading. , 2006, Journal of periodontology.

[25]  I. Turkyilmaz,et al.  Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols. , 2006, Clinical oral implants research.

[26]  I. Turkyilmaz,et al.  A short-term clinical trial on selected outcomes for immediately loaded implant-supported mandibular overdentures. , 2006, International Journal of Prosthodontics.

[27]  I. Turkyilmaz Clinical and radiological results of patients treated with two loading protocols for mandibular overdentures on Brånemark implants. , 2006, Journal of clinical periodontology.

[28]  T. Stenberg,et al.  Three-year data from a randomizd, controlled study of early loading of single-stage dental implants supporting maxillary full-arch prostheses. , 2006, The International journal of oral & maxillofacial implants.

[29]  B. Engquist,et al.  Simplified methods of implant treatment in the edentulous lower jaw: a 3-year follow-up report of a controlled prospective study of one-stage versus two-stage surgery and early loading. , 2005, Clinical implant dentistry and related research.

[30]  B. Engquist,et al.  Simplified methods of implant treatment in the edentulous lower jaw. Part II: Early loading. , 2004, Clinical implant dentistry and related research.

[31]  T. Stenberg,et al.  Early loading of ITI implants supporting a maxillary full-arch prosthesis: 1-year data of a prospective, randomized study. , 2004, The International journal of oral & maxillofacial implants.

[32]  Dean Morton,et al.  Consensus statements and recommended clinical procedures regarding loading protocols for endosseous dental implants. , 2004, The International journal of oral & maxillofacial implants.

[33]  D. Altman,et al.  Measuring inconsistency in meta-analyses , 2003, BMJ : British Medical Journal.

[34]  A. Tawse‐Smith,et al.  Conventional and early loading of unsplinted ITI implants supporting mandibular overdentures. , 2002, Clinical oral implants research.

[35]  W. Thomson,et al.  Early loading of unsplinted implants supporting mandibular overdentures using a one-stage operative procedure with two different implant systems: a 2-year report. , 2002, Clinical implant dentistry and related research.

[36]  A. K. Røynesdal,et al.  A comparative clinical investigation of 2 early loaded ITI dental implants supporting an overdenture in the mandible. , 2001, The International journal of oral & maxillofacial implants.

[37]  K. Nilner,et al.  Early functional loading of Brånemark dental implants: 5-year clinical follow-up study. , 2000, Clinical implant dentistry and related research.

[38]  G. Smith,et al.  Bias in meta-analysis detected by a simple, graphical test , 1997, BMJ.

[39]  L Sennerby,et al.  Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. , 1997, Clinical oral implants research.

[40]  N. Laird,et al.  Meta-analysis in clinical trials. , 1986, Controlled clinical trials.

[41]  Y Zilberman,et al.  Osseous adaptation to continuous loading of rigid endosseous implants. , 1984, American journal of orthodontics.

[42]  P. Branemark,et al.  Osseointegrated titanium fixtures in the treatment of edentulousness. , 1983, Biomaterials.

[43]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[44]  P. Branemark,et al.  Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. , 1977, Scandinavian journal of plastic and reconstructive surgery. Supplementum.

[45]  J Schatzker,et al.  The effect of movement on the holding power of screws in bone. , 1975, Clinical orthopaedics and related research.