Seismic Response Reduction of Structures using Smart Base Isolation System

In this study, control performance of a smart base isolation system consisting of a friction pendulum system (FPS) and a magnetorheological (MR) damper has been investigated. A fuzzy logic controller (FLC) is used to modulate the MR damper so as to minimize structural acceleration while maintaining acceptable base displacement levels. To this end, a multi-objective optimization scheme is used to optimize parameters of membership functions and find appropriate fuzzy rules. To demonstrate effectiveness of the proposed multi-objective genetic algorithm for FLC, a numerical study of a smart base isolation system is conducted using several historical earthquakes. It is shown that the proposed method can find optimal fuzzy rules and that the optimized FLC outperforms not only a passive control strategy but also a human-designed FLC and a conventional semi-active control algorithm. Keywords—Fuzzy logic controller, genetic algorithm, MR damper, smart base isolation system

[1]  Satish Nagarajaiah,et al.  Control of Sliding‐Isolated Bridge with Absolute Acceleration Feedback , 1993 .

[2]  Visit Likhitruangsilp Neuro-fuzzy control of a multi-degree of freedom structure with semi-active magnetorheological dampers , 2002 .

[3]  C. Fonseca,et al.  GENETIC ALGORITHMS FOR MULTI-OBJECTIVE OPTIMIZATION: FORMULATION, DISCUSSION, AND GENERALIZATION , 1993 .

[4]  Andrei M. Reinhorn,et al.  Control of Sliding-Isolated Buildings Using Sliding-Mode Control , 1996 .

[5]  James M. Kelly,et al.  Robust control of base-isolated structures under earthquake excitation , 1987 .

[6]  Peter J. Fleming,et al.  Genetic Algorithms for Multiobjective Optimization: FormulationDiscussion and Generalization , 1993, ICGA.

[7]  Kalyanmoy Deb,et al.  A Fast Elitist Non-dominated Sorting Genetic Algorithm for Multi-objective Optimisation: NSGA-II , 2000, PPSN.

[8]  P. N. Roschke,et al.  SEMI-ACTIVE CONTROLLED BASE-ISOLATION SYSTEM WITH MAGNETORHEOLOGICAL DAMPER AND PENDULUM SYSTEM , 2002 .

[9]  Dean Karnopp,et al.  Vibration Control Using Semi-Active Force Generators , 1974 .

[10]  W. Marsden I and J , 2012 .

[11]  Takuji Kobori,et al.  Actual seismic response controlled building with semi-active damper system , 1999 .

[12]  Billie F. Spencer,et al.  Intelligent Base Isolation Systems , 1998 .

[13]  Faryar Jabbari,et al.  Robust control techniques for buildings under earthquake excitation , 1994 .

[14]  Michael C. Constantinou,et al.  Semi-active control systems for seismic protection of structures: a state-of-the-art review , 1999 .

[15]  Kazuo Yoshida,et al.  LQG Control and H.INF. Control of Vibration Isolation for Multi-Degress-of-Freedom Systems. , 1995 .