Synchrotron Radiation as a Modulated Source for Fluorescence Lifetime Measurements and for Time-Resolved Spectroscopy

The fundamental properties of synchrotron radiation as a spectroscopic source are enhanced by the additional quality of time modulation of the source intensity over a broad range of modulation frequencies. This time modulation is a result of the dynamics of accelerators and storage rings. It depends mainly on a balance between longitudinal focusing and damping due to the magnetic lattice and the radio frequency drive and to excitation due to the emission of synchrotron radiation. The spectral profile, state of polarization, and angular distribution of emitted radiation as a function of frequency can be calculated explicitly for any accelerator or storage ring source in terms of its known parameters. The time modulation of the emitted intensity is proportional to the electron beam current modulation seen traversing a single azimuth in the accelerator. The circulating beam in the storage ring is preserved by continuously restoring energy lost to synchrotron radiation with radio frequency (rf) power, usually in the range of from 10 to 500 MHz. In a working storage ring, although the bunch length is set primarily by the frequency of the accelerating field, the bunch shape is also modified by the magnitude of the circulating current and by the internal geometry of the vacuum chamber that contains the electron beam. The complexity of the interactions between the bunch and the walls of the vacuum chamber are such that the bunch shape is difficult to predict exactly for a new storage ring and is best determined empirically as a function of the various operating parameters of the storage ring.

[1]  M. Lee,et al.  Spear II Performance , 1975, IEEE Transactions on Nuclear Science.

[2]  G. Beck Photodiode and holder with 60 psec response time , 1976 .

[3]  M. Karplus,et al.  Dynamics of folded proteins , 1977, Nature.

[4]  C. Bénard,et al.  Statistical properties of synchrotron radiation , 1974 .

[5]  N. Schwentner,et al.  A system for time and energy resolved VUV luminescence spectroscopy using synchrotron radiation for excitation , 1978 .

[6]  H. Haar,et al.  Phase fluorometer for measurement of picosecond processes. , 1978, The Review of scientific instruments.

[7]  R. López-Delgado Comments on the application of synchrotron radiation to time-resolved spectrofluorometry , 1978 .

[8]  K. Sauer,et al.  Measurement of very short fluorescence lifetimes by single-photon counting. , 1976, The Review of scientific instruments.

[9]  I Munro,et al.  Subnanosecond motions of tryptophan residues in proteins. , 1979, Proceedings of the National Academy of Sciences of the United States of America.

[10]  MATTHEW SANDS,et al.  PHYSICS OF ELECTRON STORAGE RINGS. AN INTRODUCTION. , 2018 .

[11]  H. Szwarc,et al.  Time-resolved excitation spectra of xenon vapor in the 1500 Å region , 1977 .

[12]  R. Steiner,et al.  Excited states of proteins and nucleic acids , 1972 .

[13]  Ian H. Munro,et al.  Photophysical properties of DPH derivatives , 1979 .

[14]  Branko Leskovar,et al.  Photon counting system for subnanosecond fluorescence lifetime measurements , 1976 .

[15]  O. B. D'azy,et al.  No fluorescence decay from low-lying electronic states excited into single vibronic levels with synchrotron radiation , 1975 .

[16]  A. Grinvald The use of standards in the analysis of fluorescence decay data. , 1976, Analytical biochemistry.

[17]  L. Lindqvist,et al.  Lifetime and time-resolved fluorescence measurements with aco synchrotron radiation , 1974 .

[18]  B. Selinger,et al.  Single photon decay spectroscopy. , 1973 .

[19]  J. Lakowicz,et al.  Quenching of protein fluorescence by oxygen. Detection of structural fluctuations in proteins on the nanosecond time scale. , 1973, Biochemistry.

[20]  J. Haselgrove,et al.  The design and use of a camera for low-angle X-ray diffraction experiments with synchrotron radiation , 1977 .

[21]  V. Rehn,et al.  Photoluminescence Decay in Solid Xenon , 1977 .

[22]  I. Munro,et al.  External heavy atom effects on the decay of the triplet state of aromatic hydrocarbons III. The decay functions of fluorescence and phosphorescence of carbazole in the presence of KI , 1978 .

[23]  B. Sipp,et al.  Fluorescence decay time measurements in tetracene crystals excited with synchrotron radiation , 1976 .

[24]  B. Alpert,et al.  Fluorescence lifetimes of haem proteins excited into the tryptophan absorption band with synchrotron radiation , 1976, Nature.

[25]  B. Valeur Analysis of time-dependent fluorescence experiments by the method of modulating functions with special attention to pulse fluorometry , 1978 .

[26]  E. Menzel,et al.  Picosecond-resolution fluorescence lifetime measuring system with a cw laser and a radio. , 1978, The Review of scientific instruments.

[27]  D. A. Shirley,et al.  Time resolved VUV spectroscopy using synchrotron radiation: fluorescent lifetimes of atomic Kr and Xe☆ , 1977 .

[28]  P. Wilson,et al.  Bunch Lengthening and Related Effects in SPEAR II , 1977, IEEE Transactions on Nuclear Science.

[29]  P. Wahl,et al.  The wavelength dependence of the response of a pulse fluorometer using the single photoelectron counting method , 1974 .

[30]  R. D. Dyson,et al.  Studies on the analysis of fluorescence decay data by the method of moments. , 1973, Biophysical journal.

[31]  E. W. Schlag,et al.  Single photon phase fluorimetry with nanosecond time resolution , 1974 .

[32]  I. Munro,et al.  A new pulsed light source for lifetime studies and time resolved spectroscopy: the synchrotron radiation from an electron storage ring , 1974 .

[33]  H. Stöckmann A new method to analyse composite exponential decay curves , 1978 .

[34]  J. Yguerabide,et al.  Nanosecond fluorescence spectroscopy of macromolecules. , 1972, Methods in enzymology.