Experimental and Simulation Studies for the Optimization of Dedicated Scintimammography Cameras

The main drawback of scintimammography with conventional gamma cameras is the large distance between detector and breast, which limits imaging performance and adds significant background noise from the heart and other organs. These limitations can be minimized by dedicated gamma cameras placed in tight contact with the breast. The purpose of this study was to determine the lowest Tumor-to-Background (T:B) ratio for detectable lesions and the smallest lesions that can be imaged with a dedicated system. The system is based on an R3292 position sensitive photomultiplier tube (PSPMT) from Hamamatsu, coupled to a 10 cm in diameter CsI(Tl) crystal and a general purpose collimator with hexagonal holes. Two crystals were assessed, with pixel size of 2 × 2 mm2 and 3 × 3 mm2. The experimental setup consists of a cylindrical breast phantom, cylindrical tumor phantoms positioned inside the breast phantom at various depths, and a heart phantom. The same setup, as well as some additional tumor phantoms, were modeled with the GATE simulation toolkit, following the validation of the entire system. A 20% energy window and the Dual Energy Window Subtraction Method (DEWSM) for scatter correction were applied in experimental and simulation data. In all measurements 99mTc was used. Signal to Noise Ratio (SNR) and contrast were measured in all experiments and used for quantification of results. Experimental and simulation results show that the lowest T:B ratio that can be detected is 2:1 with tumor phantom volume ≥ 0.25 ml at 1 cm depth. The smallest volume of a tumor phantom that can be detected is 0.04 ml with T:B ratio equal to 9:1 at 1 cm depth.

[1]  Michael V Knopp,et al.  A comprehensive overview of radioguided surgery using gamma detection probe technology , 2009, World journal of surgical oncology.

[2]  F Sánchez,et al.  Performance tests of two portable mini gamma cameras for medical applications. , 2006, Medical physics.

[3]  D. Berman,et al.  Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  Renato Campanini,et al.  Tumor SNR analysis in scintimammography by dedicated high contrast imager , 2001 .

[5]  B. Welch,et al.  Optimizing pinhole and parallel hole collimation for scintimammography with compact pixellated detectors , 2002 .

[6]  Carrie B. Hruska,et al.  Molecular Breast Imaging: Advantages and Limitations of a Scintimammographic Technique in Patients with Small Breast Tumors , 2007, The breast journal.

[7]  Francesco Scopinaro,et al.  High-resolution scintimammography improves the accuracy of technetium-99m methoxyisobutylisonitrile scintimammography: use of a new dedicated gamma camera , 1999, European Journal of Nuclear Medicine.

[8]  M. O’Connor,et al.  CZT detectors: How important is energy resolution for nuclear breast imaging? , 2006, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[9]  Rachel F Brem,et al.  High-resolution scintimammography: a pilot study. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  A. Jemal,et al.  Global Cancer Statistics , 2011 .

[11]  Martin P Tornai,et al.  Mammotomography with pinhole incomplete circular orbit SPECT. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  M. O’Connor,et al.  A Monte Carlo Model for Energy Spectra Analysis in Dedicated Nuclear Breast Imaging , 2008, IEEE Transactions on Nuclear Science.

[13]  Paul Kinahan,et al.  A combined PET/CT scanner for clinical oncology. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  Orazio Schillaci,et al.  Breast scintigraphy today: indications and limitations , 2004, European Journal of Nuclear Medicine and Molecular Imaging.

[15]  Khalid Alzimami,et al.  Investigation of the potential use of LaBr3:Ce scintillators for scintimammography imaging , 2011 .

[16]  Craig S. Levin,et al.  Detector design issues for compact nuclear emission cameras dedicated to breast imaging , 2003 .

[17]  Rachel F Brem,et al.  Occult breast cancer: scintimammography with high-resolution breast-specific gamma camera in women at high risk for breast cancer. , 2005, Radiology.

[18]  Umberto Veronesi,et al.  Sentinel lymph node biopsy in pregnant patients with breast cancer , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[19]  Francesco Scopinaro,et al.  Dedicated gamma camera for single photon emission mammography (SPEM) , 1997 .

[20]  S Stute,et al.  GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy , 2011, Physics in medicine and biology.

[21]  Giuliano Mariani,et al.  Sentinel Lymph Node Biopsy in Patients with Breast Cancer , 2008 .

[22]  I Buvat,et al.  Importance of the choice of the collimator for the detection of small lesions in scintimammography: a phantom study. , 2001, Physics in medicine and biology.

[23]  Habib Zaidi,et al.  Review of Computational Anthropomorphic Anatomical and Physiological Models , 2009, Proceedings of the IEEE.

[24]  B. Welch,et al.  A novel readout concept for multianode photomultiplier tubes with pad matrix anode layout , 2006 .

[25]  Paul E Kinahan,et al.  The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements , 2008, Physics in medicine and biology.

[26]  I Buvat,et al.  Impact of scatter correction in planar scintimammography: a phantom study. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[27]  N. Burgio,et al.  Imaging probe for breast cancer localization , 2003 .

[28]  A. Del Guerra,et al.  Portable gamma camera for clinical use in nuclear medicine , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[29]  K. Smith,et al.  SPECT-CT system for small animal imaging , 2001 .

[30]  Konstantina S. Nikita,et al.  A modification of the dual energy window subtraction method for scatter compensation in pixelized scintillators for SPECT , 2004 .

[31]  Francesco Scopinaro,et al.  New imaging probe with crystals integrated in the collimator's square holes , 2005 .

[32]  B. Welch,et al.  Optimization of breast imaging procedure with dedicated compact gamma cameras , 2003 .

[33]  S. Majewski,et al.  Performance of a PSPMT based detector for scintimammography. , 2000, Physics in medicine and biology.

[34]  Jocelyn A. Rapelyea,et al.  Evaluation of a high-resolution, breast-specific, small-field-of-view gamma camera for the detection of breast cancer , 2003 .

[35]  G De Vincentis,et al.  The role of Compton background and breast compression on cancer detection in scintimammography. , 1997, Anticancer research.

[36]  M.I. Saripan,et al.  Monte Carlo Simulation on Breast Cancer Detection Using Wire Mesh Collimator Gamma Camera , 2009, IEEE Transactions on Nuclear Science.

[37]  Roberto Pani,et al.  Clinical evaluation of pixellated NaI:Tl and continuous LaBr3:Ce, compact scintillation cameras for breast tumors imaging , 2007 .

[38]  Amanda L. Weinmann,et al.  Design of optimal collimation for dedicated molecular breast imaging systems. , 2009, Medical physics.

[39]  B. Welch,et al.  Optimization of dedicated scintimammography procedure using detector prototypes and compressible phantoms , 2000 .

[40]  Jennifer A. Harvey,et al.  Tomographic Dual Modality Breast Scanner , 2008, Digital Mammography / IWDM.

[41]  A. Del Guerra,et al.  Custom breast phantom for an accurate tumor SNR analysis , 2002, IEEE Transactions on Nuclear Science.

[42]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[43]  Sergi Vidal-Sicart,et al.  The use of a portable gamma camera for preoperative lymphatic mapping: a comparison with a conventional gamma camera , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[44]  A. Del Guerra,et al.  Tomographic approach to single-photon breast cancer imaging with a dedicated dual-head camera with VAOR (SPEMT): Detector characterization , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[45]  Charles R. Tenney,et al.  A staggered array of pinhole cameras for dedicated breast SPECT , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[46]  William W. Moses,et al.  Monte Carlo simulation of breast tumor imaging properties with compact, discrete gamma cameras , 1999 .

[47]  Viviane,et al.  Technetium-99m-sestamibi uptake in breast tumor and associated lymph nodes. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[48]  K F Koral,et al.  SPECT dual-energy-window Compton correction: scatter multiplier required for quantification. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.