Ultrasound detection of vascular decompression bubbles: the influence of new technology and considerations on bubble load.

INTRODUCTION Diving often causes the formation of 'silent' bubbles upon decompression. If the bubble load is high, then the risk of decompression sickness (DCS) and the number of bubbles that could cross to the arterial circulation via a pulmonary shunt or patent foramen ovale increase. Bubbles can be monitored aurally, with Doppler ultrasound, or visually, with two dimensional (2D) ultrasound imaging. Doppler grades and imaging grades can be compared with good agreement. Early 2D imaging units did not provide such comprehensive observations as Doppler, but advances in technology have allowed development of improved, portable, relatively inexpensive units. Most now employ harmonic technology; it was suggested that this could allow previously undetectable bubbles to be observed. METHODS This paper provides a review of current methods of bubble measurement and how new technology may be changing our perceptions of the potential relationship of these measurements to decompression illness. Secondly, 69 paired ultrasound images were made using conventional 2D ultrasound imaging and harmonic imaging. Images were graded on the Eftedal-Brubakk (EB) scale and the percentage agreement of the images calculated. The distribution of mismatched grades was analysed. RESULTS Fifty-four of the 69 paired images had matching grades. There was no significant difference in the distribution of high or low EB grades for the mismatched pairs. CONCLUSIONS Given the good level of agreement between pairs observed, it seems unlikely that harmonic technology is responsible for any perceived increase in observed bubble loads, but it is probable that our increasing use of 2D ultrasound to assess dive profiles is changing our perception of 'normal' venous and arterial bubble loads. Methods to accurately investigate the load and size of bubbles developed will be helpful in the future in determining DCS risk.

[1]  R. Nishi,et al.  [abstract] INTRAVASCULAR DOPPLER-DETECTED BUBBLES AND DECOMPRESSION SICKNESS. , 1990 .

[2]  R. Eckenhoff,et al.  Human dose-response relationship for decompression and endogenous bubble formation. , 1990, Journal of applied physiology.

[3]  H. Moulinier,et al.  Detection of bubbles in blood vessels and the evaluation of their flow , 1978, Medical and Biological Engineering and Computing.

[4]  J M Waligora,et al.  Information about venous gas emboli improves prediction of hypobaric decompression sickness. , 1998, Aviation, space, and environmental medicine.

[5]  W. Edwards,et al.  Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. , 1984, Mayo Clinic proceedings.

[6]  P. Burns Harmonic imaging with ultrasound contrast agents. , 1996, Clinical radiology.

[7]  F. Seddon,et al.  The effect of pre-dive exercise timing, intensity and mode on post-decompression venous gas emboli. , 2011, Diving and hyperbaric medicine.

[8]  Z. Dujic,et al.  High incidence of venous and arterial gas emboli at rest after trimix diving without protocol violations. , 2010, Journal of applied physiology.

[9]  A. Bove,et al.  Risk of decompression sickness with patent foramen ovale. , 1998, Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc.

[10]  M. Spencer,et al.  Investigation of New Principles for Human Decompression Schedules Using Doppler Ultrasonic Blood Bubble Detection , 1974 .

[11]  O. Eftedal,et al.  Comparison of three different ultrasonic methods for quantification of intravascular gas bubbles. , 2001, Undersea & Hyperbaric Medicine.

[12]  G. Loveman,et al.  The effect of breathing hyperoxic gas during simulated submarine escape on venous gas emboli and decompression illness. , 2003, Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc.

[13]  R. J. Shephard,et al.  Venous and Arterial Bubbles at Rest after No-Decompression Air Dives , 2012 .

[14]  P. Wilmshurst,et al.  RELATION BETWEEN INTERATRIAL SHUNTS AND DECOMPRESSION SICKNESS IN DIVERS , 1989, The Lancet.

[15]  O Eftedal,et al.  Agreement between trained and untrained observers in grading intravascular bubble signals in ultrasonic images. , 1997, Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc.

[16]  S. Tønjum,et al.  Gas bubbles in the circulation of divers after ascending excursions from 300 to 250 msw. , 1986, Journal of applied physiology.

[17]  K. Jurd,et al.  Pre-dive exercise and post-dive evolution of venous gas emboli. , 2012, Aviation, space, and environmental medicine.

[18]  John B. West,et al.  Respiratory Physiology - the Essentials , 1979 .

[19]  M. Schwerzmann,et al.  Risk of decompression illness among 230 divers in relation to the presence and size of patent foramen ovale. , 2004, European heart journal.

[20]  J. Lubbers,et al.  An ultrasonic detector for microgasemboli in a bloodflow line. , 1977, Ultrasound in medicine & biology.

[21]  J. Buckey,et al.  Dual-frequency ultrasound detection of stationary microbubbles in tissue. , 2009, Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc.

[22]  B D Butler,et al.  The lung as a filter for microbubbles. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.

[23]  J. Buckey,et al.  Microbubble detection following hyperbaric chamber dives using dual-frequency ultrasound. , 2011, Journal of applied physiology.

[24]  Tom S Neuman,et al.  Arterial gas embolism and decompression sickness. , 2002, News in physiological sciences : an international journal of physiology produced jointly by the International Union of Physiological Sciences and the American Physiological Society.

[25]  S. Daniels,et al.  Ultrasonic imaging system for the study of decompression-induced gas bubbles. , 1979, Undersea biomedical research.

[26]  G. W. Johnston,et al.  Numerical studies of the spectrum of low‐intensity ultrasound scattered by bubbles , 1985 .

[27]  T. Desser,et al.  Tissue harmonic imaging techniques: physical principles and clinical applications. , 2001, Seminars in ultrasound, CT, and MR.

[28]  R. Moon,et al.  PATENT FORAMEN OVALE AND DECOMPRESSION SICKNESS IN DIVERS , 1989, The Lancet.

[29]  F. Verstappen,et al.  Effects of pulmonary gas embolism on circulation and respiration in the dog , 2004, Pflügers Archiv.

[30]  O. Eftedal,et al.  Detecting intravascular gas bubbles in ultrasonic images , 1993, Medical and Biological Engineering and Computing.

[31]  Jay C Buckey,et al.  Dual-frequency ultrasound for detecting and sizing bubbles. , 2005, Acta astronautica.

[32]  B. Butler,et al.  Size distribution of intravascular air emboli produced by decompression. , 1981, Undersea biomedical research.