Benefits of FACTS devices for power exchange among Jordanian interconnection with other countries

Transmission system is the backbone of the electrical power delivery system. It is essential to maintain safety and efficient operations of the transmission system on both steady state and transient using different methods to improve the overall performance of the power system. In addition to construct new transmission lines, Flexible AC transmission system (FACTS) are effective devices to increase the transfer capacity, improve different stability aspects, and control the power flow especially for the interconnected systems. The Mediterranean Ring, a major international electric power interconnection project initially conceived of during the 1960s. It plans to connect electric power transmission grids among the countries that encircle the Mediterranean Sea. Hashemite Kingdom of Jordan reigns over a strategic location among the middle-east countries. It is bordered with Iraq, Syria, Saudi Arabia, Israel, and the Palestinian Authority Territory. Power transfer capabilities between Jordan and its neighboring countries play important role in the effectiveness of the Mediterranean Ring. This paper studies the impact of FACTS on the performance of Jordanian transmission system under different levels of power exchange with Egyptian and Syrian power systems. This helps to determine the appropriate types and locations for FACTS devices to be installed to improve these limits

[1]  E. S. Ibrahim Interconnection of electric power systems in the Arab world , 1996 .

[2]  Y. Z. Sun,et al.  Power Flow Control Approach to Power Systems with Embedded Facts Devices , 2002, IEEE Power Engineering Review.

[3]  Y. H. Song,et al.  Available transfer capability enhancement using FACTS devices , 2003 .

[4]  O. Faucon,et al.  Preparation for the synchronous interconnection of four power systems: study of the interconnection of the systems of Egypt and Jordan to Syria and Turkey , 1999, PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376).

[5]  T. Hammons,et al.  African electricity infrastructure interconnections and electricity exchanges , 2000 .

[6]  Peerapol Jirapong,et al.  Optimal allocation of FACTS devices to enhance total transfer capability using evolutionary programming , 2005, 2005 IEEE International Symposium on Circuits and Systems.

[7]  Tom Hammons,et al.  African regional power pools: status, plans of action, further development and recommendations , 2005 .

[8]  R. Adapa,et al.  The study of voltage problems in Polish power system , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[9]  Mahmoud Moghavvemi,et al.  Effects of FACTS devices on static voltage stability , 2000, 2000 TENCON Proceedings. Intelligent Systems and Technologies for the New Millennium (Cat. No.00CH37119).

[10]  J. J. Paserba How FACTS controllers benefit AC transmission systems , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).

[11]  J.J. Paserba How FACTS controllers-benefit AC transmission systems , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).